• Title/Summary/Keyword: Without bone graft

Search Result 265, Processing Time 0.051 seconds

Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft (상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구)

  • Hwang, Hee-Sun;Jung, Ji-Hye;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: This study is to evaluate the clinical significance of implantation with simultaneous bone graft by comparing the marginal bone loss around maxillary anterior implants with or without bone graft. Materials and methods: Patients treated with implant-retained restorations on maxillary anterior region at Implant Center, Dental Hospital, Wonkwang University between June 2011 and May 2014 were included in this study. Date of implant placement, implant diameter, implant length, implant-abutment connection type and whether the bone graft was done were investigated. The patient's periapical radiographs taken immediately after implantation and at the most recent visit were compared. Marginal bone loss was measured using Emago advanced v5.6 program (Oral diagnostic systems, Amsterdam, Netherlands). Statistical analysis was done in independent t-test by using SPSS 22.0 program. Results: As a result of observing on 83 implants (without bone graft: 44, with bone graft: 39) of 52 patients for 6 - 45 months (average: 18.4 months), implants without bone graft showed $1.42{\pm}0.42mm$, implants with bone graft showed $1.28{\pm}0.45mm$ of marginal bone loss. Conclusion: In limitations of this study, implants with simultaneous bone graft had significantly less marginal bone loss than implants without bone graft.

New bone formation in the maxillary sinus without bone grafts:Covering of lateral window with non-resorbable membrane or bony window (골이식재를 사용하지 않은 상악동 거상술:골창의 패쇄방법에 따른 치험례)

  • Son, Dong-Seok;Lee, Ji-Su;An, Mi-Ra;Sin, Hong-In
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.222-231
    • /
    • 2008
  • Various maxillary sinus floor augmentation techniques were common performed and in the most cases, many kinds of bone graft materials were used. The graft materials are autogenous bone or other biomaterials of human, animal or synthetic origin. But these cases report describes a new surgical technique by which dental implants are inserted in a void space created by elevating the sinus membrane without additional graft material in atrophic posterior maxilla. We created lateral bony window using piezoelectric device and elevated the schneiderian membrane in five patients and was repositioned with bony window in five patients, without any bone graft. From the clinical and histological results, it is found there is potential capacity for bone formation and placement of implants in the maxillary sinus without the use of bone grafts or bone substitutes.

  • PDF

Comparison of the bone healing capacity of autogenous bone, demineralized freeze dried bone allograft, and collagen sponge in repairing rabbit cranial defects

  • Hur, Jung-Woo;Yoon, Suk-Ja;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.221-230
    • /
    • 2012
  • Objectives: This study sought to evaluate the efficacy of collagen graft materials, as compared to other graft materials, for use in healing calvarial defects in rabbits. Materials and Methods: Ten mm diameter calvarial defects were made in ten rabbits. The rabbits were then divided into 4 groups: control, autogenous bone graft, SureOss graft, and Teruplug graft. Bone regeneration was evaluated using histological and radiographic methods. Results: Based on visual examination, no distinct healing profile was observed. At 4 weeks after treatment, histological analysis showed there was no bone regeneration in the control group; however, at 8 weeks after treatment, new bone formation was observed around the margin of the defective sites. In the autogenous bone graft group, new bone formation was observed at 4 weeks after treatment and mature bone was detected around the grafted bone after 8 weeks. In the SureOss graft group, at 4 weeks after treatment, acute inflammatory and multinuclear cells were noted around the grafted materials; at 8 weeks after treatment, a decrease in graft materials coupled with new bone formation were observed at the defective sites. In the Teruplug graft group, new bone formation was detected surrounding the bone margin and without signs of inflammation. There were statistically significant differences observed between the graft and control group in terms of bone density as evidenced by radiographic analysis using computed tomography (P<0.05), particularly for the autogenous bone graft group (P<0.001). Conclusion: These results suggested that autogenous bone, SureOss and Teruplug have the ability to induce bone regeneration as compared to an untreated control group. The osteogenic potential of Teruplug was observed to be lower than that of autogenous bone, but similar to that of SureOss.

The rate and stability of mandibular block bone graft in recent 5 years

  • Park, Jong-Cheol;Kim, Yun-Ho;Choi, Hong-Seok;Oh, Jong-Shik;Shin, Sang-Hun;Kim, Yong-Deok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.21.1-21.6
    • /
    • 2017
  • Background: The purposes of the present study were to compare implant stabilities of mandibular block bone graft and bovine bone graft and to evaluate influencing factors for implant stability in mandibular block bone (MBB) graft. Methods: This retrospective study investigated 1224 cases and 389 patients treated by one surgeon in the Department of Oral and Maxillofacial Surgery of Pusan National University Dental Hospital (Yangsan, Korea) between January 2010 and December 2014. Proportions that MBB graft cases constitute in all implant restoration cases and in all bone graft cases were measured. Implant stability quotient (ISQ) values were achieved by the same surgeon before loading. The average ISQ values of the experimental groups were compared. In addition, ISQ values of influencing factors, such as age, sex, implant size, and implant placement site, were compared within the MBB group using $Osstell^{TM}$ Mentor ($Osstell^{(R)}$, $G{\ddot{o}}teborg$, Sweden). Paired t test and ANOVA were conducted for statistical analysis with a significance level of 0.05. Results: Fifty-five percent of all implant restoration cases performed bone graft while MBB cases constituted 34% of all implant restoration cases and 61% of all bone graft cases. Comparing ISQ values according to bone graft materials, the MBB group manifested sufficient implant stability by presenting comparable ISQ value to that of the experimental group without bone graft. Among the reviewed factors, females, mandibular molar regions, and implants in larger diameter displayed greater implant stabilities. Conclusions: Satisfactory implant stability was accomplished upon administration of MBB graft. Within the limitation of this study, gender, implant site, and implant diameter were speculated to influence on implant stability in MBB graft.

Comparison of healing pattern with or without bone graft after odontogenic cyst enucleation (악골에서 발생한 치성 낭종제거 후 골이식 여부에 따른 치유속도와 양상 비교)

  • Baek, Chae-Hwan;Park, Joon-Hyung;Kim, Gun-Jong;Hong, Jong-Rak;Kim, Chang-Soo;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.6
    • /
    • pp.515-519
    • /
    • 2010
  • Introduction: Bone defects in the jaw are frequently observed after odontogenic cyst enucleation. The success of bone healing appears to be related to the size of the bone defect, the anatomical location, the patient's age and other parameters. The use of bone grafting material is dependent on the operator's preference. No evidence-based definite treatment protocol has been established. This study evaluated the effect of a bone graft into the defect after odontogenic cyst enucleation. Materials and Methods: A total of 55 patients, who had been treated for an odontogenic cyst with cyst enucleation from 2000 to 2009 at the department of Oral and Maxillofacial Surgery, Samsung Medical Center, were included in this study. Patients who were followed-up for more than 1 year were included. Two groups were defined according to the bone graft (with or without a bone graft) after cyst enucleation. The differences in the healing periods and patterns of bone healing were compared clinically and radiologically. The postoperative 1 year radiographs were analyzed for bone healing and density. Statistical analysis was performed using a Pearson chi square test and Wilcoxon rank-sum test. Results: More infection signs were observed in the bone graft group than in the other group, but there was no statistically significant difference. Radiographically, there was also no significant difference in the size of the radiolucent lesions between the two groups. Conclusion: There was no significant difference in healing between the groups with a bone graft and without bone graft after cyst enucleation.

A COMPARATIVE STUDY ON THE STRENGTH AND THE BONE FORMATION AT THE RATS CALVARIAL DEFECTS OF DFDB GRAFT AND THOSE OF THE COMPOSITE GRAFT WITH DFDB AND RESORBABLE HYDROXYAPATITE (백서 두개골 결손부에 동결 건조 동종 탈회골을 단일매식한 경우와 동결 건조 동종 탈회골과 흡수성 수산화인회석을 복합매식한 경우의 강도 및 골형성에 관한 비교 연구)

  • Seo, Young-Ho;Yim, Chang-Joon;Lee, Jae-Il
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.6
    • /
    • pp.557-564
    • /
    • 2000
  • The bone graft materials can be grossly divided into autogenous bone, allogenic bone, xenogenic bone, and alloplastic material. Much care was given to other bone graft materials away from autogenous bone due to its additional operation for harvesting, delayed resorption and limitation of quantity. Demineralized freeze-dried bone(DFDB) and hydroxyapatite are the representatives of bone graft materials. As resorbable hydroxyapatite is developed in these days, the disadvantage of nonresorbability can be overcome. So we planned to study on the strength and the bone formation at the rats calvarial defects of DFDB graft and those of the composite graft with DFDB and resorbable hydroxyapatite. We used the 16 male rats weighting range from 250 to 300 gram bred under the same environment during same period. After we made the 6mm diameter calvarial defect, we filled the DFDB in 8 rats and DFDB and resorbable hydroxyapatite in another 8 rats. We sacrificed them at the postoperative 1 month and 2 months with the periostium observed. As soon as the specimens were delivered, we measured the compressive forces to break the normal calvarial area and the newly formed bone in calvarial defect area using Instron(Model Autograph $S-2000^{(R)}$, Shimadzu, Japan). The rest of the specimens were stained with H&E(Hematoxylin & Eosin) and evaluated with the light microscope. So we got the following results. 1. In every rats, there was no significant difference between the measured forces of normal bone area and those of the bone graft area. 2. In 1 month, the measured forces at DFDB graft group were higher than those of the DFDB and resorbable hydroxyapatite composite graft group(P<0.05). 3. In 2 months, there was no significant differences between the measured forces of DFDB graft group and those of the DFDB and resorbable hydroxyapatite composite graft group. 4. In lightmicroscopic examination, most of the grafted DFDB were transformed into bone in 1 month and a large numbers of hydroxyapatite crystal were observed in DFDB and resorbable hydroxyapatite composite graft group in 1 month. 5. Both group showed no inflammatory reaction in 1 month. And hydroxyapatite crystals had a tight junction without soft tissue invagination when consolidated with newly formed bone. 6. In both groups, newly formed bone showed the partial bone remodeling and the lamellar bone structures and some of reversal lines were observed in 2 months. From the above results, it is suggested that DFDB and resorbable hydroxyapatite composite graft group had a better resistance to compressive force in early stage than DFDB graft group, but there would be no significant difference between two groups after some period. And it is suggested that the early stage of bone formation procedure of DFDB and resorbable hydroxyapatite composite graft group was slight slower than that of DFDB graft group, but there would be no significant difference between two groups after some period.

  • PDF

Tomographic and histometric analysis of autogenous bone block and synthetic hydroxyapatite block grafts without rigid fixation on rabbit calvaria

  • Bae, Soo-Yong;Park, Jung-Chul;Shin, Hyun-Seung;Lee, Yong-Keun;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.5
    • /
    • pp.251-258
    • /
    • 2014
  • Purpose: The preferred material for bone augmentation beyond the envelope of skeletal bone is the bone block graft, due to its dimensional stability. We evaluated the necessity of rigid fixation for the bone block graft, and compared the bone regeneration and volume maintenance associated with grafting using a synthetic hydroxyapatite block (HAB) and an autogenous bone block (ABB) without rigid fixation on rabbit calvaria over two different periods. Methods: Cylinder-shaped synthetic HAB and ABB were positioned without fixation on the rabbit calvarium (n=16). The animals were sacrificed at 4 or 8 weeks postoperatively, and the grafted materials were analyzed at each healing period using microcomputed tomography and histologic evaluation. Results: Integration of the graft and the recipient bed was observed in all specimens, although minor dislocation of the graft materials from the original position was evident in some specimens (six ABB and ten HAB samples). A tendency toward progressive bone resorption was observed in the grafted ABB but not in the grafted HAB, which maintained an intact appearance. In the HAB group, the area of new bone increased between 4 and 8 weeks postoperatively, but the difference was not statistically significant. Conclusions: The nonfixed HAB was successfully integrated into the recipient bed after both healing periods in the rabbit calvaria. In spite of limited bone formation activity in comparison to ABB, HAB may be a favorable substitute osteoconductive bone material.

THE EFFECT OF NEW BONE FORMATION OF ONLAY BONE GRAFT USING VARIOUS GRAFT MATERIALS WITH A TITANIUM CAP ON THE RABBIT CALVARIUM (가토의 두개골에서 티타늄 반구를 이용한 다양한 onlay bone graft시 골형성 능력)

  • Park, Young-Jun;Choi, Guen-Ho;Jang, Jung-Rok;Jung, Seung-Gon;Han, Man-Seung;Yu, Min-Gi;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.469-477
    • /
    • 2009
  • Purpose: This study was performed to evaluate the effect of various graft materials used with a titanium cap on the ability of new bone formation in the rabbit calvarium. Materials and Methods: A total of 32 sites of artificial bony defects were prepared on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter. Each rabbit had two defect sites. 0.2 mm deep grooves were formed on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter for the fixation of a titanium cap. The treatments were performed respectively as follows: without any graft for the control group (n=8), autogenous iliac bone graft for experimental group 1 (n=8), alloplastic bone graft ($SynthoGraft^{(R)}$, USA) for experimental group 2 (n=8), and xenogenic bone graft ($NuOss^{(R)}$, USA) for experimental group 3 (n=8). After the treatments, a titanium cap (8 mm in diameter, 4 mm high, and 0.2 mm thick) was fixed into the groove. At the third and sixth postoperative weeks, rabbits in each group were sacrificed for histological analysis. Results: 1. In gross examination, the surgical sites showed no signs of inflammation or wound dehiscence, and semicircular-shaped bone remodeling was shown both in the experimental and control groups. 2. In histological analysis, the control group at the third week showed bone remodeling along the inner surface of the cap and at the contact region of the calvarium without any specific infiltration of inflammation tissue. Also, there was no soft tissue infiltration. Bone remodeling was observed around the grafted bone and along the inner surface of the titanium cap in experimental group 1, 2, and 3. 3. Histologically, all groups at the sixth week showed the increased area of bone remodeling and maturation compared to those at the third week. In experimental group 2, the grafted bone was partially absorbed by multi nucleated giant cells and new bone was formed by osteoblasts. In group 3, however, resorption of the grafted bone was not observed. 4. Autogenous bone at the third and sixth week showed the most powerful ability of new bone formation. The size of newly formed bone was in decreasing order by autogenous, alloplastic, and heterogenous bone graft. There was no statistically significant difference among autogenous, alloplastic, and heterogenous bones(p>0.05). Summary: This result suggests that autogenous bone is the best choice for new bone formation, but when autogenous bone graft is in limited availability, alloplastic and xenogenic bone graft also can be an alternative bone graft material to use with a suitably guided membrane.

Porcine study on the efficacy of autogenous tooth bone in the maxillary sinus

  • Lee, Du Han;Yang, Keun Yong;Lee, Jeong Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.3
    • /
    • pp.120-126
    • /
    • 2013
  • Objectives: This study sought to elucidate the effect of autogenous tooth bone material by experimenting on minipig's maxillary sinus and performing histological and histomorphometric analyses. Materials and Methods: Five 18-24 month-old male minipigs were selected, and right maxillary sinuses were grafted with bone graft material made of their respective autogenous teeth extracted eight weeks earlier. The left sides were grafted with synthetic hydroxyapatite as control groups. All minipigs were sacrificed at 12 weeks after bone graft, which was known to be 1 sigma (${\sigma}$) period for pigs. Specimens were evaluated histologically under a light microscope after haematoxylin-eosin staining followed by semi-quantitative study via histomorphometric analysis. The ratio of new bone to total area was evaluated using digital software for calculation of area. Results: All specimens were available, except one on the right side (experimental group), which was missing during specimen preparation. This study demonstrated new bone at the periphery of the existing bone in both groups, showing evidence of bone remodeling, however, encroachment of new bone on the central part of the graft at the 1 ${\sigma}$ period was observed only in the autogenous tooth bone group (experimental group). Histomorphometric analysis showed more new bone formation in the experimental group compared to the control group. Although the difference was not statistically significant (P>0.05), the mean percentage area for new bone for the experimental and control groups were $57.19%{\pm}11.16%$ and $34.07%{\pm}13.09%$, respectively. Conclusion: The novel bone graft material using autogenous tooth is a good alternative to autogenous bone, comparable to autogenous bone, and outperforming synthetic hydroxyapatite bone graft materials in terms of bone regeneration capacity. Augmentation with autogenous tooth bone materials will reduce donor site morbidity without hampering the safety of the autogenous bone graft.

A COMPARATIVE STUDY OF VARIOUS TYPE OF AUTOGENEOUS BONE GRAFT ON THE RABBIT-SKULL DEFECT HEALING (가토 두개골에 이식한 다양한 형태의 자가골에 의한 골성 회복 양상 비교 평가)

  • Choi, So-Young;Lee, Su-Youn;Kim, Jin-Wook;Kim, Chin-Soo;Lee, Sang-Han;Shin, Hong-In;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.428-434
    • /
    • 2008
  • Introduction: Piezosurgery device is one of the most commonly used instrument on the intraoral surgery such as maxillary sinus lift and autogeneous bone graft. Piezosurgery instrument also contains the tips that are manufactured especially for the convenient bone graft, which now many surgeons apply them for collecting bone graft materials in the curettage method for the restoration of skull defects. However, objective data has not been shown concerning the effects about bone graft with using Piezosurgery. Therefore we investigated the effects of Piezosurgery on the rabbit-skull defect healing. Materials & Methods: To investigate the regeneration of the bony defect with various bone graft, 10 adult New Zealand white rabbits (average weight : $2.8{\pm}0.3kg$, about 12weeks) were used. The four circular bony defects measuring 6mm in diameter were made with Piezosurgery device on each rabbit cranial bone. The harvested bone tissues during defect formation were also used for autogeneous bone graft. They were grafted into the defects in a various type; block type (Group 1), particulated type by the bone mill (Group 2), chopped type by curette shaped Piezosurgery tip (Group 3), the defect without any graft was served as control (control group). The animals were sacrificed after 6 weeks and bone regeneration capacity was evaluated histomorphometrically. Result & Conclusion: Autogeneous bone graft harvested using a Piezosurgery instrument showed satisfactory bone regeneration. There was no conspicuous difference bone prepared among by bone mill or Piezosurgery and block bone graft. Therefore, the bone harvested from the intraoral site near the operation field using the piezosurgery device can be a feasible and reliable graft for intraoral bony defects.