• Title/Summary/Keyword: With-Corona

Search Result 830, Processing Time 0.03 seconds

Spectroscopic Detection of Alfvenic Waves in the Chromosphere of Sunspot Regions

  • Chae, Jongchul;Cho, Kyuhyoun;Nakariakov, Valery M.;Cho, Kyung-Suk;Kwon, Ryun-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.47.1-47.1
    • /
    • 2021
  • Transverse magnetohydrodynamic waves often called Alfvénic (or kink) waves have been often theoretically put forward to solve the outstanding problems of the solar corona like coronal heating, solar wind acceleration, and chemical abundance enhancement. Here we report the first spectroscopic detection of Alfvénic waves around a sunspot at chromospheric heights. By analyzing the spectra of the Hα line and Ca II 854.2 nm line, we determined line-of-sight velocity and temperature as functions of position and time. As a result, we identified transverse magnetohydrodynamic waves pervading the superpenumbral fibrils. These waves are characterized by the periods of 2.5 to 4.5 minutes, and the propagation direction parallel to the fibrils, the supersonic propagation speeds of 45 to 145 km s-1, and the close association with umbral oscillations and running penumbral waves in sunspots. Our results support the notion that the chromosphere around sunspots abounds with Alfvénic waves excited by the mode conversion of the upward-propagating slow magnetoacoustic waves.

  • PDF

Characteristics of Silicon Oxide Thin Films Prepared by Atomic Layer Deposition Using Alternating Exposures of SiH2Cl2 and O3 (SiH2Cl2 와 O3을 이용한 원자층 증착법에 의해 제조된 실리콘 산화막의 특성)

  • Lee Won-Jun;Lee Joo-Hyeon;Han Chang-Hee;Kim Un-Jung;Lee Youn-Seung;Rha Sa-Kyun
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.90-93
    • /
    • 2004
  • Silicon dioxide thin films were deposited on p-type Si (100) substrates by atomic layer deposition (ALD) method using alternating exposures of $SiH_2$$Cl_2$ and $O_3$ at $300^{\circ}C$. $O_3$ was generated by corona discharge inside the delivery line of $O_2$. The oxide film was deposited mainly from $O_3$ not from $O_2$, because the deposited film was not observed without corona discharge under the same process conditions. The growth rate of the deposited films increased linearly with increasing the exposures of $SiH_2$$Cl_2$ and $O_3$ simultaneously, and was saturated at approximately 0.35 nm/cycle with the reactant exposures over $3.6 ${\times}$ 10^{9}$ /L. At a fixed $SiH_2$$Cl_2$ exposure of $1.2 ${\times}$ 10^{9}$L, growth rate increased with $O_3$ exposure and was saturated at approximately 0.28 nm/cycle with $O_3$ exposures over$ 2.4 ${\times}$ 10^{9}$ L. The composition of the deposited film also varied with the exposure of $O_3$. The [O]/[Si] ratio gradually increased up to 2 with increasing the exposure of $O_3$. Finally, the characteristics of ALD films were compared with those of the silicon oxide films deposited by conventional chemical vapor deposition (CVD) methods. The silicon oxide film prepared by ALD at $300^{\circ}C$ showed better stoichiometry and wet etch rate than those of the silicon oxide films deposited by low-pressure CVD (LPCVD) and atmospheric-pressure CVD (APCVD) at the deposition temperatures ranging from 400 to $800^{\circ}C$.

A Study on Social Welfare Field Practice in With COVID-19 Era: Focusing on Universities, Trainees, Training Institutions, and Practical Performance (위드 코로나(With COVID-19)시대 사회복지 현장실습에 대한 연구: 대학, 실습생, 실습기관, 실습성과를 중심으로)

  • Son, Hee Won
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.7
    • /
    • pp.405-419
    • /
    • 2022
  • The purpose of this study is to find out the progress of social welfare field practice at students, universities, and training institutions in Seoul and Gyeonggi Province during the With COVID-19 era, and to suggest effective social welfare field practice operation plans. To this end, a survey was conducted on 181 people who completed social welfare field practice courses, and the final research results are as follows. First, the operation situation of practice institutions in the era of With COVID-19 was the highest when they were conducted together with 'face-to-face, non-face-to-face', and student satisfaction was positive when partial non-face-to-face practice education was conducted. Despite repeated shutdowns due to COVID-19, the degree of participation in face-to-face services was more than 9 times and the number of supervision was more than 6 times, and many responded that the quality of supervision, a social welfare field training institution, was "generally high." Second, as a result of examining the level of practice performance, trainees, and training institutions, there was a significant relationship between training institution factors and practice performance, and third, as a result of examining how the university, trainees, training institution factors, and practice performance. Therefore, in order to derive the results of social welfare field practice in the era of With Corona, programs to promote and strengthen non-face-to-face exchanges at the university level are necessary, and an education system that also provides non-face-to-face practice guidance suitable for the With Corona era. In addition, various support for the practice system of government ministries and related institutions, including universities and practice institutions, is needed.

AC Breakdown Characteristics of Pure Ar, $N_2$ Gas and Ar/$N_2$ Gas Mixutres under Uniform and Non-Uniform Fields (평등 및 불평등 전계하에서 순수 Ar, $N_2$가스와 Ar/$N_2$혼합 가스의 교류절연파괴 특성)

  • 이상우;김인식;이동인;이광식;김이국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, the AC breakdown characteristics of pure Ar and $N_2$gas with gas pressure range of 58.8~137.3[kPa] under uniform and non-uniform fields were investigated, and the measured values were compared with those in Ar/$N_2$gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of pure $N_2$gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and the AC breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/$N_2$ gas mixtures were decreased with decreasing the mixture ratio of $N_2$gas. In case of Ar(85%)/$N_2$(15%) and Ar(70%)/$N_2$(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.5 and 2.1 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[kPa]. Also, corona inception voltage of Ar(70%)/$N_2$(30%) gas mixtures under non-uniform field were increased about 1.5 times than those of pure Ar gas.

  • PDF

The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator (전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구)

  • Lee, Kang-Wuk;Park, Jeong-Ho;Jang, Seong-Ho;Lim, Woo-Taik;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

Preparation and characterization of Poly(2-methacryloyloxyethyl phosphorylcholine/fluorescein O-methacrylate)-coated iron oxide nanoparticles (Poly(2-methacryloyloxyethyl phosphorylcholine/fluorescein O-methacrylate)가 도입된 산화철 나노 입자의 제조 및 발열 특성 연구)

  • Ryu, Sunggon;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.19 no.3
    • /
    • pp.106-112
    • /
    • 2018
  • Recently, the hyperthermia treatment of malignant tissues has gained great attention as a biocompatible and benign method that facilitates successful cancer therapy compared to radiation and chemotherapy. In this study, superparamagnetic ($Fe_3O_4$) iron oxide nanoparticles (IONP) coated with biocompatible polymer (IONP@P(MPC/FOM)) for the purpose of hyperthermia treatment were prepared and related characterization were performed. IONPs with having 15 nm diameter were first prepared by coprecipitation and followed by surface modification with 4-cyanopentanoic acid dithiobenzoate (CTP) for reversible addition-fragmentation chain transfer (RAFT) copolymerization by using 2-methacryloyloxyethyl phosphorylcholine (MPC) and fluorescein O-methacrylate (FOM) to form corona layer of P(MPC/FOM) on the surface of the IONP. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) confirmed the morphology and hydrodynamic size of the IONP@P(MPC/FOM) and thermogravimetric analysis (TGA) confirmed the formation of P(MPC/FOM) corona layer, respectively. Exposing IONP dispersion to alternating magnetic field suggests that the IONP@P(MPC/FOM) aqueous dispersion with 0.2 wt.% can be used for hyperthermia treatment.

Performance Characteristics of a Pin-to-Cylinder Superposed Discharge Type Ozonizer (SDO)

  • Md. Fayzur Rahman;Lee, Kwang-Sik
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.113-119
    • /
    • 2001
  • This paper presents a model for a pin-to-cylinder discharge type ozonizer, which utilizes the superposition of surface discharge and corona discharge operation. By changing the gas flow rate, the discharge power and the number of SDO units, the characteristics of ozone concentration ( $O_{3con}$), ozone generation ( $O_{3g}$) and ozone yield ( $O_{3Y}$) were investigated. Using one SDO unit the maximum values of $O_{3con}$, $O_{3g}$ and $O_{3Y}$ were found as 8100[ppm], 1623[mg/h] and 213[g/kWh] respectively. With two SDO units the corresponding values were found as 12800[ppm], 2893[mg/h] and 248[g/kWh] respectively. Hence using two SDO units the efficiency was improved by 16[%].y 16[%].

  • PDF

Analysis of efficient ozonizer character using high-frequency Inverter (고주파 인버터를 이용한 고농도 오존발생기 특성 해석)

  • Kim, Y.H.;Hwang, Y.M.;Noh, I.B.;Kim, Y.B.;Woo, S.H.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1006-1008
    • /
    • 2002
  • Recently deep interests and attractions have been paid on the generation of ozone with environment polisy. Especially, which is widely used to remove bad smell and to clear water. This paper presents control and performance of a voltage source IGBT inverter developed for silent corona discharge type ozonizer. And proposed addition circuit for maintain discharge the center of in the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of ozonizer is investigated in the simulation and experimental results.

  • PDF

ESP by using Half-bridge ZCS resonant inverter and Cockroft-Walton circuit (Half-Bridge ZCS resonant inverter 및 Cockroft-Walton회로를 사용한 공기 청정기에 관한 연구)

  • Park, Jong-Woong;Jeong, Jong-Jin;Chung, Hyun-Ju;Joung, Jong-Han;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1951-1953
    • /
    • 2004
  • In this study, we propose a small high voltage power supply which use a half-bridge ZCS resonant and Cockroft-Walton on circuit, for ESP (Electrostatic Precipitator). This power supply transfers energy from ZCS resonant inverter to step-up transformer and the transformer secondary is applied to the Cockroft-Walton circuit for generating high voltage as discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50 % in this ESP.

  • PDF

Electron Density and Electron Temperature in Atmospheric Pressure Microplasma

  • Tran, T.H.;Kim, J.H.;Seong, D.J.;Jeong, J.R.;You, S.J.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.152-152
    • /
    • 2012
  • In this work we measured electron temperature and electron density of a microplasma by optical emission spectroscopy. The plasma is generated from a small discharge gap of a microwave parallel stripline resonator (MPSR) in Helium at atmospheric pressure. The microwave power supplied for this plasma source from 0.5 to 5 watts at a frequency close to 800 MHz. The electron temperature and electron density were estimated through Collisional-radiative model combined with Corona-equilibrium model. The results show that the electron density and temperature of this plasma in the case small discharge gap width are higher than that in larger gap width. The diagnostic techniques and associated challenges will be presented and discussed.

  • PDF