• Title/Summary/Keyword: Wireless Communication Module

Search Result 480, Processing Time 0.038 seconds

The development of module for measurement and wireless communication of SpO2/PPG signals (혈중산소포화도/맥파 신호 측정 및 무선 전송을 위한 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.981-986
    • /
    • 2011
  • In this paper, the module for measuring SpO2 and PPG(Photo Plethysmo Graphy) signal of human body and the module for wireless communication of these bio-signals to PC were developed. The program was developed to display transmitted SpO2 and PPG signal by various type data and graph without information loss during a emergency transfer. This system can be utilized as appropriate for remote medical care and a new market is expected, to be created according to revision of medical law.

Development of communication module for the wireless transmission of oxygen saturation(SpO2) and display software (산소 포화도의 무선 전송을 위한 통신모듈 및 디스플레이 소프트웨어 개발)

  • Han, Young-Oh
    • Journal of Digital Contents Society
    • /
    • v.11 no.2
    • /
    • pp.277-282
    • /
    • 2010
  • In this paper, the wireless transmission module is developed to transmit oxygen saturation(SpO2) signal, acquired from bio-signal measuring module, to PC. This wireless transmission module is designed with closed type protocol instead of open type protocol such as a zigbee or a bluetooth, considering of the security of personal medical informations. The display software is also developed to display transmitted SpO2 signals by various type data and graph without information loss for a emergency transfer.

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

A multiple PLC wireless communication module using master-slave control concept (Mastey-Slave 개념을 이용한 PLC용 다대다 통신 모듈 개발)

  • 박종석;현웅근;김이곤
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.48-48
    • /
    • 2000
  • We developed a wireless communication system for multiple instrumentation system. The developed system has a function of remote instrumentation and PLC(Programmable Logic Controller) control. The system consists of CC(Control and Communication) protocol, wireless media access and physical media system. For multiple wireless communication, we propose a hub polling protocol based on master-slave control concept. To show the validity of the developed system, several experiments are illustrated.

  • PDF

Development of Wire/Wireless Communication Modules using Environmental Sensor Modules for LNG Storage Tanks (LNG 저장탱크용 환경 센서 모듈을 이용한 유무선 통신 모듈 개발)

  • Park, Byong Jin;Kim, Min Sung
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.4
    • /
    • pp.53-61
    • /
    • 2022
  • Accidents are steadily occurring due to machine defects and carelessness during LNG storage operations. In previous studies, an environmental sensor module capable of measuring pressure, temperature, gas concentration, and flow to detect danger in advance was developed and the response speed according to the amount of leaked gas was measured. This paper proposes the development of a wired and wireless communication module that transmits data measured by the environmental sensor module to embedded devices connected to wired and wireless networks of SPI, UART, and LTE. First, a data communication module capable of interworking with an environmental sensor is designed. Design a protocol between devices in the Local Control Part and wired and wireless protocols in the Local Control Part and Remote Control Part. Ethernet, WiFi, and LTE communication modules were designed, and UART and SPI channels that can be linked with embedded controllers were designed. As a result, it was confirmed through a UI (User Interface) that each embedded device transmits data measured by the environmental sensor module while simultaneously communicating on a wired and wireless basis.

System of gas sensor for conbinating wire and wireless using Internet of Things (IOT기술을 이용한 유무선 통합 가스검출 시스템 구현)

  • Bang, Yong-Ki;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.297-304
    • /
    • 2015
  • This study concerns the integrated gas sensor system of wire and wireless communication by using IoT(Internet of Things) technology. First, communication part is that it delivers the detection information, which transferred by wire or wireless communication and required control procedure based on a wireless module that receives the gas leakage information from wired or wireless detector, to administrator or user's terminal. Second, receiver part is that it shows the location and information, which received from the wired detector formed by a detecting sensor's node as linking with the communication part, and transfers these to the communication part. Third, wireless detector formed as a communication module of a detecting sensor node is that it detects gas leakage and transfers the information through wireless as a packet.Fourth, wired detector communicated with the receiver part and formed as a communication module of a detecting sensor node is that it detects gas leakage, transfers and shows the information as a packet. Fifth, administrator's terminal is that it receives gas leakage information by the communication part, transfers the signal by remote-control, and shut off a gas valve as responding the information. Sixth, database is that it is connected with the communication part; it sets and stores the default values for detecting smoke, CO., and temperature; it transfers this information to the communication part or sends a gas detecting signal to user's terminal. Seventh, user's terminal is that it receives each location's default value which stored and set at the database; it manages emergency situation as shutting off a gas valve through remote control by corresponding each location's gas leakage information, which transferred from the detector to the communication part by wireless.It is possible to process a high quality data regarding flammable or toxic gas by transferring the data, which measured by a sensor module of detector, to the communication part through wire and wireless. And, it allows a user to find the location by a smart phone where gas leaks. Eventually, it minimizes human life or property loss by having stability on gas leakage as well as corresponding each location's information quickly.

An asynchronous near-field multiple wireless remote measurement and control system (비동기 근거리 다대다 무선원격 계측-제어 시스템 개발)

  • Hyun, Woong-Keun;Choi, Hyun-Suck
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2225-2227
    • /
    • 2001
  • A wireless communication module for multiple nearfiled measurement and control module was developed. The function of the developed system are dual communication, concurrent multiple communication, PLC control, and A/D, D/A converting. The multiple communication approach is based on master-slave with sub-polling scanning concept.

  • PDF

Implementation of Real-Time Channel Module for Applying Wireless Communication Environments (무선 통신 환경 적용이 가능한 실시간 채널 모듈 구현)

  • Park, Chan Ju;Kim, Woojoong;Jang, Byung-Jun;Yoon, Hyungoo;Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.438-444
    • /
    • 2016
  • In this paper, A real-time channel module which can apply the wireless propagation channel was developed using USRP and Lab-VIEW. When the proposed channel module is used in conjunction with the implemented HW(hardware) simulators for cognitive radio and frequency interference analysis and so on, it can increase the reliability about wireless propagation environments. In addition, the proposed module overcomes the limit of existing HW simulator that data transfer rate is limitative in communication system through the design of the inner parts. Along with this, it is possible to apply channel parameters necessary to estimate the easier communication performance. Also, this has the advantage that it can be flexibly applied in implementing the communication channel with the upcoming new scenarios. The proposed module can estimate the communication performance via constellation and BER using the implemented module.

Implementation of Wireless Charger with the Function of Auto-Shutdown for fully Implantable Middle Ear Hearing Devices (완전 이식형 인공중이를 위한 자동 충전종료형 무선 충전장치의 구현)

  • Lee, Jang-Woo;Lim, Hyung-Gyu;Jung, Eui-Sung;Han, Ji-Hun;Lee, Seung-Hyun;Park, Il-Yong;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.539-548
    • /
    • 2007
  • In the paper, a wireless charger with the function of auto-shutdown for fully implantale middle ear hearing devices (F-IMEHD) has been designed. The wireless charger can communicate with an implant module to be turned off automatically shutdown after an internal rechargeable battery has been fully-charged by electromagnetic coupling using two coils. For the communication with an implant module, the wireless charger uses the load shift keying (LSK) method. But, the variation of the mutual inductance due to the different distance between two coils can cause the communication error in receiving the fully-charged signal from an implant module. To solve the problem, the implemented wireless charger has a variable reference generator for LSK communication. The wireless charger generates proper level of the reference voltage for a comparator using an ADC (analog-to-digital converter) and a DAC (digital-to-analog converter). Through the result of experiment, it has been confirmed that the presented wireless charger can detect signals from implantable module. And wireless charger can stop generating electromagnetic flux after an implanted battery has been fully charged in spite of variable coil distance according to different skin thickness.

A Study on Implementation of Zigbee Module based on CC520 (CC2520 기반의 지그비 모듈 구현에 대한 연구)

  • Moon, Yong-Seon;Bae, Young-Chul;Roh, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.664-671
    • /
    • 2010
  • In this paper, we developed a Zigbee module based on CC2520 which is possible to construct the mesh network and also support to Zigbee Pro standard as a preceding research of autonomous moving of mobile robot using Zigbee. After manufacturing the Zigbee module, we selected antenna to fit Zigbee wireless frequency band using network analyze as means performance improvement. We also carry out an impedance matching of Zigbee module, extend the possible distance of two-way wireless communication and ensure the safety of communication.