• 제목/요약/키워드: Windows area

검색결과 406건 처리시간 0.025초

공동주택의 배치유형에 따른 창호 시스템의 채광특성 (Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses)

  • 김곤;노지웅
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

도시지역 비점오염원 관리를 위한 SWMM의 적용 -포항시를 대상으로- (Application of SWMM for Management of the Non-point Source in Urban Area -Case Study on the Pohang City-)

  • 이재용;장성호;박진식
    • 한국환경보건학회지
    • /
    • 제34권3호
    • /
    • pp.247-254
    • /
    • 2008
  • Non-point source pollution that originates from surface applied chemicals in either liquid or solid form is a part of urban activities and it appears in the surface runoff caused by rainfall. This study investigates the characteristics of non point source pollution in relation to storm events and the first washing effect in the Study area, which is comprised of different land use types. Then, a Best Management Practices (BMP) model, for urban areas, is applied with the Storm water Management Model (SWMM) Windows Interface which was developed by the EPA in the USA. During the storm event analysis of the hydrographic and pollutographic data showed that the peak of pollutants concentration was within the peak flow, 30 to 60 minute into the storm event in the Study area. The results of simulation using SWMM Windows Interface, Structure Techniques as applied in the study were highly efficient for removal of pollutants. Predicted removal efficiency was 26.0% for SS, 22.1 for BOD, 24.1% for COD, 20.6% for T-N, and 21.6% for T-P, respectively.

전통주거건축 공간구성에 따른 안방창호 구성에 관한 연구 - 전라남도 지역 중상류 주택을 중심으로 - (A Study on the Windows and Doors of the Main Room by Space Organization of the Traditional Residental Architecture - Focus on the Upper Middle Class in Jeonlanamdo -)

  • 조성우;이재홍;문출성;천득염
    • 한국주거학회논문집
    • /
    • 제25권3호
    • /
    • pp.1-12
    • /
    • 2014
  • Korean traditional house has inherented construction characteristics that contain human requirements with the adaptation to nature's order. As for traditional buildings, there are a lot of facilities like palaces, Buddhist temples, Confucianism architectures, government facilities, etc. Among them, housing construction is not only closely connected to our lives, but also plays an important role to connect our lives from the past to present. The master room in a traditional korean house is responsible for playing a center role of the residential life which implies the traditional values responsible for multi-functions and it is also the sphere of the living space. Therefore, this thesis considers the residential environmental adjustment method and the behaviors centered around the main buildings of Jeonnam Province. And also investigates the main reason for windows and doors formation. From this, we would like to further evaluate the master room life, and the inner space constructions following the spacial and organizational analysis of windows and doors. We would like to analyze the space organization methods, environmental adjustment methods and the usages of traditional buildings. Using the modern interpretation as basis, we would like to use the foundation materials to reflect single family housing plans.

초단열 슈퍼윈도우의 건물에너지효율등급 적용 연구 (A study on the Insulation Performance of the Super Window applied to building energy efficiency rating)

  • 장철용;김치훈;안병립
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.205-210
    • /
    • 2009
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. According to the flow of energy is lost from the building, will be achieved through the walls and roof and windows. Among these, the window through the loss of about 45% of the entire building is big enough to rate. In addition, the building regulation U-value Limitation of window is $3.3W/m^2$ K in southern regions, while U-value Limitation of wall is $0.35{\sim}0.58W/m^2$ K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1)Thermal performance of insulated Super Window measured as $1.44W/m^2$ $^{\circ}C$ 2)Required energy for heating was cut down about 5.3% from 266.99 $MJ/m^2$ yr to 252.85 $MJ/m^2$ yr 3)Super Window's reduction rates increased 4.1% from 31.48% to 35.58% when it is compared to normal windows. 4)Building energy efficiency rating elevated from 2nd rating to 1st rating.

  • PDF

Design and Walking Control of the Humanoid Robot, KHR-2(KAIST Humanoid Robot-2)

  • Kim, Jung-Yup;Park, Ill-Woo;Oh, Jun-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1539-1543
    • /
    • 2004
  • This paper describes platform overview, system integration and dynamic walking control of the humanoid robot, KHR-2 (KAIST Humanoid Robot - 2). We have developed KHR-2 since 2003. KHR-2 has totally 41 DOF (Degree Of Freedom). Each arm including a hand has 11 DOF and each leg has 6 DOF. Head and trunk also has 6 DOF and 1 DOF respectively. In head, two CCD cameras are used for eye. In order to control all joints, distributed control architecture is adopted to reduce the computation burden of the main controller and to expand the devices easily. The main controller attached its back communicates with sub-controllers in real-time by using CAN (Controller Area Network) protocol. We used Windows XP as its OS (Operating System) for fast development of main control program and easy extension of peripheral devices. And RTX, HAL(Hardware Abstraction Layer) extension program, is used to realize the real-time control in Windows XP environment. We present about real-time control of KHR-2 in Windows XP with RTX and basic walking control algorithm. Details of the KHR-2 are described in this paper.

  • PDF

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 (A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

MFMIS 게이트 구조에서의 메모리 윈도우 특성 (Characteristics of Memory Windows of MFMIS Gate Structures)

  • 박전웅;김익수;심선일;염민수;김용태;성만영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.319-322
    • /
    • 2003
  • To match the charge induced by the insulators $CeO_2$ with the remanent polarization of ferro electric SBT thin films, areas of Pt/SBT/Pt (MFM) and those of $Pt/CeO_2/Si$ (MIS) capacitors were ind ependently designed. The area $S_M$ of MIS capacitors to the area $S_F$ of MFM capacitors were varied from 1 to 10, 15, and 20. Top electrode Pt and SBT layers were etched with for various area ratios of $S_M\;/\;S_F$. Bottom electrode Pt and $CeO_2$ layers were respectively deposited by do and rf sputtering in-situ process. SBT thin film were prepared by the metal orgnic decomposition (MOD) technique. $Pt(100nm)/SBT(350nm)/Pt(300nm)/CeO_2(40nm)/p-Si$ (MFMIS) gate structures have been fabricated with the various $S_M\;/\;S_F$ ratios using inductively coupled plasma reactive ion etching (ICP-RIE). The leakage current density of MFMIS gate structures were improved to $6.32{\times}10^{-7}\;A/cm^2$ at the applied gate voltage of 10 V. It is shown that in the memory window increase with the area ratio $S_M\;/\;S_F$ of the MFMIS structures and a larger memory window of 3 V can be obtained for a voltage sweep of ${\pm}9\;V$ for MFMIS structures with an area ratio $S_M\;/\;S_F\;=\;6$ than that of 0.9 V of MFS at the same applied voltage. The maximum memory windows of MFMIS structures were 2.28 V, 3.35 V, and 3.7 V with the are a ratios 1, 2, and 6 at the applied gate voltage of 11 V, respectively. It is concluded that ferroelectric gate capacitors of MFMIS are good candidates for nondestructive readout-nonvolatile memories.

  • PDF

일사차단용 설비를 이용한 냉방 에너지 절약 방안 (Cooling Energy Saving System using Solar Heat Protection Dvices)

  • 정기범;최상곤
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.108-115
    • /
    • 2010
  • Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows.?In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.

루프 환기구에 따른 보일러빌딩 내부 환기성능에 관한 수치적 연구 (Numerical Study on the Ventilation Performance in the Boiler Building with and without Roof Openings)

  • 최훈기;유근종;이상헌
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.342-349
    • /
    • 2016
  • Objectives: The objective of this paper is to find flow and heat transfer characteristics numerically in boiler buildings for three different ventilation window configurations. Methods: Turbulent natural convection flow in boiler buildings with a constant heating wall temperature was analyzed numerically. Governing equations were solved with standard finite-volume method using the SIMPLE algorithm. Conclusions: Flow and heat transfer characteristics are found for three different ventilation types. In the lower area under furnace, velocity and temperature distributions show similar patterns among the three different ventilation types. In the upper area over furnace, however, air flow is well mixed with lower peak temperatures for types B and C, which have roof ventilation windows, compared to type A which has side wall louvers only. Also, type B, with a single large roof window, shows better ventilation effect than does type C with its distribution roof windows.

모델 변환 기법을 활용한 윈도우즈 모바일 어플리케이션 개발 (Development of Windows Mobile Applications using Model Transformation Techniques)

  • 김우열;손현승;김재승;김영철
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제16권11호
    • /
    • pp.1091-1095
    • /
    • 2010
  • 기존의 스마트폰용 소프트웨어 개발은 플랫폼에 종속적으로 만들어 지기 때문에 플랫폼별로 개발해야한다. 애플은 코코아플랫폼, 구글은 안드로이드, 마이크로소프트는 윈도우 모바일 퉁 각 벤더마다 고유의 플랫폼으로 개발한다. 본 논문에서는 한 번의 개발을 통해 이종의 소프트웨어 개발할 수 있도록 모델변환기법을 적용한다. 이 방법은 독립 모델과 종속 모델을 분리하고 이 둘의 차이를 변환언어를 통해 자동 변환하는 기법이다. 모델 변환 기법 수행을 위해서는 모델, 메타모델, 모델변환언어가 요구된다. 본 논문에서는 스마트폰에 적용하기 위해서 모델은 UML, 메타모델은 UML 메타모델, 모델변환언어는 ATL을 사용하였다. 적용사례로 윈도우 모바일 플랫폼환경에서 모델변환을 이용하여 개발하는 방법을 보여준다. 본 논문의 플랫폼 독립모델을 사용하고 모델 변환 규칙을 재정의 하면 아이폰, 안드로이드 등의 이종의 플랫폼으로 변환이 가능하다.