• Title/Summary/Keyword: Window transmittance

Search Result 108, Processing Time 0.021 seconds

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

Self-Illuminated Smart Window Based on Polymer-Dispersed Liquid Crystal Mixed with Cu-doped ZnS

  • Kim, Eun Mi;Heo, Gi-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.562-567
    • /
    • 2022
  • Novel self-illuminated smart windows were fabricated consisting of Cu-doped ZnS (ZnS:Cu) powder and polymer-dispersed liquid crystal (PDLC). This smart window shows not only switchable transparency but also self-illumination without any attachable luminous body. Its electro-optical characteristics, transmittance, and luminance were investigated in relation to various applied voltages and composition ratios. The optical transmittance and luminous intensity increased with increasing applied voltages. However, the optical transmittance decreased with increasing ZnS:Cu powder content. One of the self-illuminated smart windows, which was fabricated with 9 wt% of ZnS:Cu, achieved the optical transmittance of 60.5% (at 550 nm) and the luminance of 11.0 cd/m2 at 100 V. This smart window could be used as a normal switchable smart window in daytime and light-emitting signage at night.

A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance (염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구)

  • Oh, Myung-Hwan;Sim, Se-Ra;Lee, Chul-Sung;Chin, Kyung-Il;Yoon, Jong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

The improved transmittance of an IR window by coating a DLC film (DLC 박막 코팅에 의한 IR window의 적외선 투과율 향상에 관한 연구)

  • Uhm, Hyun-Seok;Park, Jin-Seok;Park, Sung-Lae;Kim, Kyu-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1340-1342
    • /
    • 1998
  • The diamond-like carbon(DLC) film, as an antireflection layer, is coated on a commerically used Ge window. DLC films are deposited by using an rf(13.56 MHz) plasma CVD. The optimal value of thickness and refractive index of DLC layer has been determined from the computer simulation. IR-transmittances of DLC-coated Ge windows are estimated by measuring FTIR spectra in the wavelength range of$ 2.5{\sim}25{\mu}m$. By coating the DLC film on one side of the Ge window, the transmittance measured at a wavelength of $10{\mu}m$ is about 60 %, while that of the bare Ge is lower than 50 %. Also, a higher transmittance up to about 90 % is obtained by coating the DLC film on both sides of the window. It may be suggested that the further improvement of the IR-transmittance can be achieved by more precisely controlling the thickness and the refractive index of DLC layer and also by adopting various muliti-layer antireflection structures.

  • PDF

A Study on Reliability of Liquid-Crystal for Smart Window (액정 스마트윈도우의 신뢰성에 대한 연구)

  • Park, Byung-Kyu;Kim, Sun-Geum;Lee, Seung-Woo;Park, Gye-Choon;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.471-474
    • /
    • 2020
  • In recent years, the challenge of higher energy efficiency has emerged as urban buildings have become taller, and the area of window glasses has increased. To address the problem of energy efficiency in buildings, research on smart windows is being actively conducted. In this study, an accelerated experiment for thermal stability was conducted to fabricate a liquid crystal cell applicable to external windows. It was confirmed from the study that the function is maintained even in a high-temperature external environment through the change in transmittance by voltage. Compared with the initial transmittance, after the passage of time, the smart window cell to which the sealant was applied showed a small change in transmittance of 1~2%. This result confirmed the thermal stability of the liquid crystal-based smart window.

Analysis of Window Transmittance Using Horizontal Blind by RADIANCE Program (RADIANCE 프로그램에 의한 창문 블라인드의 투과율 분석 연구)

  • 정근영;최안섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.7-15
    • /
    • 2003
  • The purpose of this simulation study is to determine the window transmittance by RADIANCE lighting simulation tool where the horizontal blind is installed. Parameters such as sky types, seasonal changes, altitude, azimuth, and horizontal blind angle at a 0$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$ were considered. The simulation results present that measured directional transmittances have different values according to each directional property of the horizontal blind. In addition, methodology was described to apply window transmittance data to DayDim program which is a lighting calculation and analysis tool especially for the performance of daylight responsive dimming systems.

Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation (외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량)

  • Rhee, Kyu-Nam;Jung, Gun-Joo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

Trends of Daylight Environment for Office Spaces Based on Smart-Window Installation Settings (스마트 윈도우 설치 속성에 따른 사무공간의 주광 환경 추이)

  • Jae-Hyang Kim;Seung-Hoon Han
    • New & Renewable Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 2023
  • Smart windows are capable of varying their visible light transmittance (VLT) in response to changing environmental conditions. The VLT variability of architectural windows is highly valuable because it enables indoor lighting and energy environments to align with external changes. However, challenges such as high installation costs and assurance of glass visibility have prompted the exploration of alternative solutions, including models incorporating partially applied smart windows., Prior research focused on useful daylight illuminance (UDI) analysis for south-facing office buildings, pointing out suitable areas for smart-window implementation to enhance lighting control. In this study, we broadened this scope by determining optimal smart-window application zones under changing building orientation. Furthermore, we studied the correlation between building orientation and smart-window deployment areas.

A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy (냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.