Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation

외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량

  • 이규남 (부경대학교 건축공학과) ;
  • 정근주 (부경대학교 건축공학과)
  • Received : 2017.08.24
  • Accepted : 2017.10.13
  • Published : 2017.12.26

Abstract

In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

Keywords

Acknowledgement

Supported by : 국토교통부, 부경대학교

References

  1. Cappelletti, F., Gasparella, A., Romagnoni, P., & Baggio, P. (2011). Analysis of the influence of installation thermal bridges on windows performance: The case of clay block walls. Energy and Buildings, 43(6), 1435-1442. https://doi.org/10.1016/j.enbuild.2011.02.004
  2. Chu, S., Kim, J., & Lee, M. (2014). A Study on the Thermal-bridge-free Construction Details of the Thermal Envelope for a Passive House using Heat Transfer Simulation, Journal of the Architectural Institute of Korea, Planning and Design Section, 30(5), 85-96.
  3. Chvatal, K. M. S., & Corvacho, H. (2009). The impact of increasing the building envelope insulation upon the risk of overheating in summer and an increased energy consumption. Journal of Building Performance Simulation, 2(4), 267-282. https://doi.org/10.1080/19401490903095865
  4. DoE, US. (2010). Energyplus engineering reference. The reference to energyplus calculations.
  5. Feist, W. (2003). Hochwarmedammende Fenstersysteme: Untersuchung und Optimierung im eingebauten Zustand. Technical report, Teilbericht Passivehaus Institut, Darmstadt.
  6. Fletcher, M. J., Johnston, D. K., Glew, D. W., & Parker, J. M. (2017). An empirical evaluation of temporal overheating in an assisted living Passivhaus dwelling in the UK. Building and Environment, 121, 106-118. https://doi.org/10.1016/j.buildenv.2017.05.024
  7. Gosselin, L., & Dussault, J. M. (2017). Correlations for glazing properties and representation of glazing types with continuous variables for daylight and energy simulations. Solar Energy, 141, 159-165. https://doi.org/10.1016/j.solener.2016.11.031
  8. Hong, S. & Yoon, D. (2011). A $CO_2$ Sensor based Demand Controlled Ventilation Strategies with Multi-zone Analysis in the Apartment House. Journal of the Architectural Institute of Korea, Planning and Design Section, 27(9), 341-348.
  9. International Standard Organization (ISO) (2017). ISO 10211:2007, Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations. International Standard Organization: Geneva, Switzerland.
  10. MOLIT (Ministry of Land, Infrastructure and Transportation). (2017). Building Design Standards for Energy Saving: The Notification of Ministry of Land, Infrastructure and Transportation; Korean Government: Seoul, Korea.
  11. Mun, S., Shin, S., & Yoon, Y. (2011). The Change of U-value with the Linear Thermal Transmittance of Window System, Proceedings of KIAEBS annual conference, 85-89
  12. Rhee, K., Yu, J., Song, S., & Jung, G. (2016). Design of Windows for Condensation Prevention considering the Thermal Performance of Thermally Improved Spacers, Journal of the Architectural Institute of Korea, Planning and Design Section, 32(4), 107-114.
  13. Song, S., Park, S., Koo, B., Lim, J., & Ryu, S. (2013). Performance Evaluation of EIFS Using Vacuum Insulation Panels for Passive and Zero-Energy Apartment Buildings, Journal of the Architectural Institute of Korea, Planning and Design Section, 29(9), 219-228.
  14. Song, S., Kim, Y., & Song, J. (2011). Development of Design Details for Externally Insulated Apartment Buildings, Journal of the Architectural Institute of Korea, Planning and Design Section, 27(10), 239-250.
  15. Stazi, F., Veglio, A., Di Perna, C., & Munafo, P. (2013). Experimental comparison between 3 different traditional wall constructions and dynamic simulations to identify optimal thermal insulation strategies. Energy and Buildings, 60, 429-441. https://doi.org/10.1016/j.enbuild.2013.01.032