• Title/Summary/Keyword: Winding Resistance

Search Result 161, Processing Time 0.036 seconds

A Study on Saturation Modeling of Synchronous Generator using Operating Data (운용 데이타를 이용한 동기발전기 포화 모델링에 관한 연구)

  • Kim, Kyung-Yul;Yoo, Ill-Do;Seo, Jang-Cheol;Moon, Seung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.106-109
    • /
    • 1995
  • This paper presents a new saturation modeling technique of synchronous generators using the operating data. With the stator voltages, currents and the field current directly measured on the field winding at different steady state operating conditions, it can estimate tile saturated stator mutual inductances, stator resistance and the field-stator equivalent turns ratio. Effects of the measurement noises on tile estimated parameters are also investigated.

  • PDF

Experimental Verification and Prediction of Generating Performance of PMG with Multi-Pole Rotor based on Electromagnetic Analysis and Parameter Estimation considering Skew Effects (스큐를 고려한 다극 영구자석 발전기의 전자기 특성해석/제어정수 도출을 통한 발전특성 예측 및 실험적 검증)

  • Jang, Seok-Myeong;Choi, Jang-Young;Ko, Kyoung-Jin;Park, Ji-Hoon;Lee, Sung-Ho;Kim, Ii-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.752-753
    • /
    • 2008
  • The analytical expressions for magnetic field distributions considering slotting effects, cogging torque and back-emf considering skew effects are established. On the basis of magnetic field solutions, electrical parameters such as back-emf constant and winding inductance are obtained. The predicted results are validated extensively by non-linear finite element (FE) analyses. In particular, test results such as back-emf, cogging torque, inductance and resistance measurements are given to confirm the analyses. Finally, generating performances are investigated by applying estimated parameters to equivalent circuit (EC) of the permanent magnet generator (PMG) and validated extensively by FE calculations and measurements.

  • PDF

A Study on the Improvement of Attraction Force of Solenoid Operated Valves (솔레노이드 밸브의 흡인력 개선을 위한 연구)

  • Lim, Byung-Ju;Park, Chang-Dae;Lee, Tae-Gu;Yun, So-Nam;Chung, Kyung-Yul
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.121-122
    • /
    • 2012
  • In this research, we studied on improvement of the attraction force of solenoid operated valve for normal operation in harsh environment like vessel. Attraction force of the solenoid valves is effected by the B-H characteristics of magnetic material and the size of coil. In order to specify impact of the affection, we performed the B-H characteristics test and attraction force. Test results show that magnetic flux densities of the materials are difference each other more than 2 times in same magnetic intensity, and attraction force of the solenoid valve is 1.7 times difference as changes of resistance and the number of coil winding of solenoid.

  • PDF

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

Nonlinear Analysis of the Rotor Bridge in a Induction Motor with Closed Slots (폐슬롯 구조의 회전자를 가지는 유도전동기 회전자 브릿지부분의 자기포화현상 해석)

  • Lee, Hak-Yong;Hahn, Song-Yop;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.27-29
    • /
    • 1999
  • The starting characteristics of induction motors strongly depend on the leakage reactance and resistance of stator winding and rotor circuits. The magnetic field saturation in the rotor bridge of closed slot rotor makes it very difficult to compute the leakage reactance of rotor bars. This paper describes a comparison between timestep finite element analysis, time-harmonic analysis and experimental results for a test model which can represent the nonlinear behaviour of the rotor bridge.

  • PDF

Determination of Induction Motor equivalent circuit parameters by Inverter Source (인버터 전원에 의한 유도전동기 등가회로 결정)

  • Jeong, Young-Jun;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.160-162
    • /
    • 2001
  • A determining method of the $\Gamma$ type eqivalent circuit parameters of induction motor driven by inverter source is proposed in this paper. The no-load test by rated frequency (60 Hz) and a blocked rotor test by 25% of rated frequency (l5Hz) are performed with inverter source, and the DC resistance of the stator winding is measured. To determine the more accurate parameters, four simultaneous equations obtained from equivalent circuit of the no-load test and blocked rotor test are solved by using initial values which are evaluated from simplified equivalent circuits. The induction motor performances are computed by using these parameters and compared with measured values of the tested motor. Then it is found that the compared results show good agreement between them.

  • PDF

A analysis result on the PT ferroresonance at 154 kV GIS substation (154 kV GIS의 PT 철공진 소손사례와 원인규명)

  • Woo, J.W.;Shim, E.B.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

Series-parallel resonant converter using a contactless power supply for the efficiency improvement (효율 개선을 위한 직${\cdot}$병렬 공진컨버터 적용 비접촉 전원)

  • Kong Y.S.;Lee H.K.;Kim E.S.;Cho J.G.;Kim J.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.45-48
    • /
    • 2004
  • To improve the efficiency characteristics in the resonant converter using the contact-less power supply with the large air-gap and the long primary winding, this paper suggests the three-level series-parallel resonant converter(SPRC). The voltage gain characteristics of the proposed converter have the unit gain in a resonance frequency point of the series and parallel, and input voltage and current in the primary of SPRC are always In phase for the all equivalent load resistance because of the parallel resonant tank of the high impedance. The results are verified on the simulation based on the theoretical analysis and the 4kW experimental prototype.

  • PDF

A Study on the Skewed Stator Slots and Skewed Rotor Magnet Segments of BLDCM (BLDCM에서의 스쿠슬롯과 스큐자극에 대한 고찰)

  • 김광헌;심동준;원종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.643-655
    • /
    • 1991
  • The analysis method on air gap permeance distribution, air gap MMF distribution, air gap flux density distribution, cogging torque and BEMF about the skewed stator slots or the skewed rotor magnet segments for BLDCM, respectively, is studied as a function of the skew ratio. The proposed method describes the differences between the skewed stator slots and teh skewed rotor magnet segments for the air gap permeance distribution, air gap MMF distribution and air gap flux density distribution. The reliability of the method is also confirmed by the waveform of the cogging torque and BEMF through experiments. And the result shows that the effects on the cogging torque and BEMF due to the skewed stator slots or the skewed rotor magnet segments are the same. In case of the skewed stator slots, the effects of the variations of the winding resistance and inductance are also studied.

Analysis of Cogging Torque and Characteristics in Brushless DC Motor (브러시레스 전동기의 코깅토크 해석 및 특성해석)

  • Lee, Ji-Young;Lim, Yang-Soo;Hong, Jung-Pyo;Kim, Gyu-Tak;Sin, Sang-Yun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.629-631
    • /
    • 2000
  • This paper deals with the design of a inner rotor type Brushless DC (BLDC) motor for Electric Power Steering to reduce the cogging torque. The effect of the design parameters on the characteristic and cogging torque is analyzed by Finite Element Method (FEM). The considered design parameters are as follows : the number of pole and slot. dead-zone and skew angle. and teeth shape. The winding resistance of each motor is calculated and the characteristic curve is derived from considering reactance drop voltage for original model.

  • PDF