건축 옥상 방수 신기술의 동향 (A Trend of New Waterproofing System for Building Roof)

  • 우영제;조병영;신주재;김영근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.549-552
    • /
    • 2003
  • User's demand, as a maintenance for durability of construction and a comfortable life, and an incentive systems for new waterproofing system incite waterproofing company to evolve new waterproofing system that is upgraded waterproofing quality by getting advantages for the existing waterproofing systems. There are seven new waterproofing systems for building roof to be authorized from Ministry of construction & transportation. Those are multi-layers waterproofing system, and five of those are the insulation type. A trend of new waterproofing systems for building roof is multi-layers waterproofing system insulated.

  • PDF

교량 바닥판 조건에 따른 교면방수 시스템의 인장접착 특성 (Tensile Adhesive Chracteristics of Waterproofing System for Concrete Bridge Decks)

  • 이병덕;심재원;박성기;김광우
    • 한국도로학회논문집
    • /
    • 제4권3호
    • /
    • pp.15-23
    • /
    • 2002
  • 방수시스템의 거동은 재료 인자들의 복잡한 상호작용, 설계 상세, 그리고 시공의 질에 따라 결정되고, 방수성은 교면과의 접착성과 방수재의 손상정도에 의해 결정되는 것으로 알려져 있다. 따라서 본 연구는 현재 국내에 유통되고 있는 교면방수재의 종류별로 방수시스템의 성능을 현재 각 시공현장에서 하자의 원인으로 가장 빈번하게 발생되는 요인들을 중심으로 인장접착 특성을 비교하였다. 방수시스템에 대한 인장접착강도 시험 결과, 함수비 10% 이상에서는 무기질탄성계 도막방수재를 제외하고는 접착력이 감소하였으며, 바닥판 콘크리트 강도가 증가할수록 일반적으로 인장접착강도는 증가하였다. 또한 바닥판 콘크리트의 양생방법에 따라 내부의 공극구조 및 평탄성의 차이로 인해 수중양생한 시편이 전반적으로 접착력이 더 큰 것으로 나타났다. 아스팔트 혼합물 포설전 보다 아스팔트 혼합물 포설후 인장접착강도가 증가하는 경향을 나타냈지만 도막식의 경우, 오히려 감소하는 결과가 나타났다. 그리고 방수재 시공시 대기온도가 상승함에 따라 접착력이 저하되어 방수 시스템의 성능에 악영향을 미치는 것으로 나타났다.

  • PDF

바닥판 조건에 따른 교면방수 시스템의 인장접착 특성 (Tensile Adhesive Characteristics of Waterproofing System for Concrete Bridge Decks)

  • 이병덕;박성기;심재원;정해문;김광우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.373-378
    • /
    • 2002
  • The waterproofing system's performance is known to show a determining by complex interaction of material factors, design details, and the qualify of construction, and the waterproofing integrity of waterproofing membranes is determined by the bond to the deck and the amount of damage to the waterproofing membrane. In this research, the basic properties of waterproofing membranes on market and the tensile adhesive characteristics of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. As a results of tensile adhesive strength of waterproofing system, tensile strength is decrease with surface moisture contents except for inorganic-elastomeric liquid waterproofing membrane, and increase with strength of deck slab. Also tensile adhesive strength is generally increase in case of moisture curing of specimen because of pore structure and surface leveling. The after asphalt concrete paving tends to increase more than before those. The results of the liquid waterproofing membranes are upside-down, and the more concrete has strength, the more strength of tensile adhesive increase. The ambient temperature and the rolling temperature of asphalt concrete when application of the waterproofing membrane has considerable influence on the performance of waterproofing system.

  • PDF

건축물 옥상방수층의 누수보수를 위한 방수층재형성 주입기술에 관한 연구 (Study on the injecting technology of waterproofing layer for water leakage repair of roof)

  • 배기선;조일규;장혁수;곽규성
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술.기술논문발표회
    • /
    • pp.23-27
    • /
    • 2002
  • Waterproofing is one of the important factor to improve performance of building elements. But existing repair system for waterproofing have many problems like a damage of waterproof layer due to movement of concrete substrate, blistering effect and moisture condition. So waterproofing layer can not play an important part to improve waterproofing function and performance of building. Therefore, new waterproofing system to solve these problems of existing waterproofing system is developed. In this paper, new waterproofing system in water-leakage repair for remodeling is introduced

  • PDF

계열별 교면 방수시스템의 품질관리 지침(안) 고찰 (Quality Control Recommendation with Waterproofing Membrane Type of Waterproofing System for Concrete Bridge Decks)

  • 이병덕;박성기;심재원;정해문;김광우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.367-372
    • /
    • 2002
  • The waterproofing systems of concrete bridge deck are installed under the complex circumstances, such as traffic loading, weather, and the condition of the deck concrete. For assuring the effectiveness of waterproofing system, the materials and the construction method and timing ought to be suitably selected with the procedures of waterproofing and the system has to ensure the economical performances. First of all, we discussed whether the quality and performance criteria for highway bridge deck are resonable or not through the investigation of domestic and foreign criteria. The basic properties of waterproofing membranes on market and the performance of waterproofing systems of concrete bridge deck have also been investigated in the view of the damages frequently reported from job site. In this way, the causes and measures of damages, the guidelines of design, construction, quality control, and maintenance, the test methods and criteria of membranes and waterproofing system, are proposed.

  • PDF

절연용 통기완충 시트와 폴리우레탄 도막 방수재를 복합 적층한 탈기 시스템에 관한 연구 (A Study on the Air-Vent System of Complex Layer Applied Poly-Urethane Waterproofing Material and Air-Permeability Buffer Sheet)

  • 오상근;박봉규;고장렬;박윤철;김수련
    • 한국건축시공학회지
    • /
    • 제2권1호
    • /
    • pp.139-146
    • /
    • 2002
  • This study deals with the characterizing and the application like as insulation materials in the joint part in concrete surface layer and waterproofing sheet especially for roof slabs. Using steel materials and butil-rubber tape to band waterproofing sheet and concrete surface together before this waterproofing system will be applied. It can be expected to both the curability and the watertightness by coating poly-urethane 2 or 3 times with sheet surface. Therefore this waterproofing system can be possible to protect water without the damage when vapor is going out from concrete and without air pockets because of the difference temperature inside and out. This system particularly consists of air bents and elastic waterproofing sheet considering the physical damage while water can cause purely physical damage. This system is one of the most efficient ways of waterproofing system without air pocket.

건식방수공법의 현장적용 사례 연구 (A Study of the field application on fully Dry-process Waterproofing system)

  • 윤광필;문소현;장진호;장성주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.197-202
    • /
    • 2005
  • This study started to confirm and prove for the applicability of the dry-process waterproofing system to cover the defects of the wet-process waterproofing system according to weather circumstance, foundation condition and maintenance, etc. This process has triple combined waterproofing system using asphalt sheet, metal sheet, engineering plastic film. It is not influenced by the concrete's crack as the foundation of the roof according to the movement of the building because the waterproofing system is designed for maintaining good quality by absorbing the stress of contraction and expansion that is occurred by the variation of temperature. Ali components used in this process can be recycled environmentally. The superiority of this process proved and reconfirmed through with the investigation of about 130 fields, around 30,000nf for two years.

  • PDF

알루미늄 판막과 유리섬유를 합지한 구리방근시트와 폐타이어 용융액상 도막방수재를 이용한 옥상녹화 복합방수공법 (Compound waterproofing method of green roof using copper barrier sheet and recycled tire melting liquid waterproofing material that reinforced treatments are valve and glass fiber mesh.)

  • 김영찬;조일규;최성민;김영찬
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.173-178
    • /
    • 2008
  • This is green roof bottom system which composed by aluminum valve and glass fiber together as major reinforcement, so the cooper sheet can have root proof, and using recycled tire gel-type membrane waterproofing system which dost not contains VOCs. The copper sheet reduce the plants' root growing, so it helpes to maintain the waterproofing layer and stability of root proofing. Gel type membrane waterproofing system can do waterproofing, stress dispersion, and reducing leakage expansion. So those two materials can help each other to make green roof bottom layer would have the stability and durability.

  • PDF

지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법 (Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint)

  • 오규환;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF

콘크리트 수조에 적용되는 폴리우레아 방수방식 공법의 내구성 향상을 위한 시험 평가 방법에 관한 연구 (A Study on Performance Test Method of Polyurea Waterproofing System Applied to the Concrete Water Tank)

  • 도광구;송제영;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.12-13
    • /
    • 2020
  • Construction projects and buildings are becoming taller and larger, and the size of water tanks of production facilities and high-rise buildings is also gradually increasing. Most large water tanks apply a waterproofing layer to the water tank type concrete structure. The application of polyurea coating materials, which are excellent in water resistance, chemical resistance, physical performance, rapid hardening, and workability is gradually increasing as waterproofing and anticorrosion layer for water tank. As a result, defects such as water leakage and damage to the waterproofing layer are continuously occurring, causing production disruption, setback to users. Therefore, it is required to review suitability through performance verification of the waterproofing and anticorrosion system.

  • PDF