튜브 경사각이 풀핵비등열전달에 미치는 영향 (Effects of Tube Inclination Angle on Nucleate Pool Boiling Heat Transfer)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.116-124
    • /
    • 2002
  • An experimental parametric study of a tubular heat exchanger has been carried out far the saturated water at atmospheric pressure to determine effects of tube inclination on pool boiling heat transfer. For the analysis, seven inclination angles(0°, 15°, 30°, 45°, 60°, 75°, and 90°) and two tube diameters(12.7 and 19.1 mm) were tested. According to the results, inclination angles result in very much change on pool boiling heat transfer. As the inclination angle is around horizontal or vertical, maximum or minimum heat transfer is expected, respectively. For the same wall superheat(about 5.5K) the ratio between two heat fluxes fur $\theta$ =15° and 75° has the value of more than five when the tube diameter is 12.7 mm and heat flux is increasing.

튜브 경사각이 포화풀핵비등 열전달에 미치는 영향 (Effects of Tube Inclination on Saturated Nucleate Pool Boiling Heat Transfer)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제32권5호
    • /
    • pp.327-334
    • /
    • 2008
  • Effects of tube inclination on pool boiling heat transfer have been studied for the saturated water at atmospheric pressure. For the analysis, seven inclination angles varying from the horizontal to the vertical and two tube diameters(25.4 and 30.0 mm) are tested. According to the results, inclination angles result in much change on heat transfer. For the same wall superheat(about $5.3^{\circ}C$) the ratio between two heat fluxes for the $45^{\circ}$ inclined and the vertical has the value of more than five when the tube diameter is 25.4mm. As the inclination angle is increasing from the horizontal to the vertical direction heat transfer is gradually increasing because of the increase in liquid agitation. However the detailed tendency depends on the ratio between the tube length and the diameter.

수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube)

  • 황규대;박노성;강병하
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

액체중을 상승하는 공기포의 괸벽영향 (Effect of Wall Proximity on Air Bubbles Rising in Liquid)

  • Kang, Joon Mo
    • 대한기계학회논문집
    • /
    • 제1권1호
    • /
    • pp.17-25
    • /
    • 1977
  • 관벽의 영향을 무시할 수 있는 요기내의 액체중을 상승하는 단일공기포의 상승속도, 형산, 경로를 명확히 하고 원주형관, 정방형관, 평행평판간의 액체중을 상승하는 단일기포의 상승속도에 미치는 관벽영향을 구하였다. 원주형관을 상승하는 공기포는 dimensionless plot로 실험치를 통 적으로 표현할 수가 있었으며 관벽영향을 받지않고 관중을 상승할 수 있는 공기포에 대한 최저의 관경을 결정할 수가 있었다.

수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석 (Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection)

  • 김무근;노승탁
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.142-155
    • /
    • 1992
  • 본 연구에서는 실제 빙축열 시스템의 해석을 위한 기초 모델로서 수직원관 주 위의 응고과정에 대하여 밀도차와 자연대류 효과 및 최대 밀도점을 나타내는 밀도-온 도 관계식을 도입한 수치해석과 실험을 통하여 여러가지 매개변수들이 상변화에 미치 는 영향을 알아 보았다.

이력현상이 물의 풀비등에 미치는 영향 (Hysteresis Effects in Pool Boiling of Water)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1037-1045
    • /
    • 2001
  • The effect of hysteresis in saturated pool boiling of water from stainless-steel surfaces has been investigated experimentally. Several sets of test sections of different surface conditions, geometries, orientations, diameters, lengths, and water types were tested at atmospheric pressure. The experimental results show that hysteresis effects in pool boiling heat transfer are not significant, but some appreciable trends are observed in accordance with parameters change. At higher heat flux regions, the curve for heat flux decrease is shifted to the left side of the curve for heat flux increase. To clarify hysteresis in pool boiling and to give some improvement on published correlations, four empirical correlations are obtained in terms of tube diameter, surface roughness, and tube wall superheat.

Pool Boiling Heat Transfer in Annuli with Closed Bottom

  • Kang, Myeong-Gie;Han, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.165-175
    • /
    • 2002
  • Effects of gap sizes (3.9-44.3 mm) of vertical annuli on nucleate pool boiling heat transfer of water at atmospheric pressure have been obtained experimentally. Through the study, tubes of the closed bottom have been investigated and results are compared with those of a single unconfined tube. According to the results, the annular condition gives much increase in heat transfer coefficient at moderate heat fluxes. The increase is much enhanced 3s the gap size decreases. At the same tube wall superheat (about 3.1 K) the heat transfer coefficient for the least gap size (i.e., 3.9 mm) is more than three times greater than that of the unconfined tube. However, deterioration of heat transfer occurs at high heat flux for confined boiling.

보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究 (A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler)

  • 김종보;한승탁
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.699-705
    • /
    • 1985
  • 본 논문에서는 자연 및 강제순환 모두를 실험 했으며 사용한 리브붙이 관은 관의 두께와 직경, 리브수, 리브 피치(Pitch), 높이 및 폭등을 사용 하려는 열교환기 나 보일러에 합당하도록 설계, 선정하면, 그 적용 범위는 매우 넓다고 생각돼 연구 검 토 하고자 한다.

피동 원자로건물 냉각계통 실험에 관한 수치적 연구 (Numerical Investigation on Experiment for Passive Containment Cooling System)

  • 하희운;서정수
    • 한국안전학회지
    • /
    • 제35권3호
    • /
    • pp.96-104
    • /
    • 2020
  • The numerical simulations were conducted to investigate the thermal-fluid phenomena occurred inside the experimental apparatus during a PCCS, used to remove heat released in accidents from a containment of light water nuclear power plant, operation. Numerical simulations of the flow and heat transfer caused by wall condensation inside the containment simulation vessel (CSV), which equipped with 18 vertical heat exchanger tubes, were conducted using the commercial computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the wall condensation model were used for turbulence closure and wall condensation, respectively. The simulation using the actual size of the apparatus. However, rather than simulating the whole experimental apparatus in consideration of the experimental cases, calculation resources, and calculation time, the simulation model was prepared only in CSV. Selective simulation was conducted to verify the effects of non-condensable gas(NC gas) concentration, CSV internal pressure, and wall sub-cooling conditions. First, as a result of the internal flow of CSV, it was observed that downward flow due to condensation occurred surface of the vertical tube and upward flow occurred in the distant place. Natural convection occurred actively around the heat exchanger tube. Due to this rising and falling internal flow, natural circulation occurred actively around the heat exchanger tubes. Next, in order to check the performance of built-in condensation model using according to the non-condensable gas concentration, CSV internal flow and wall sub-cooling, the heat flux values were compared with the experimental results. On average, the results were underestimated with and error of about 25%. In addition, the influence of CSV internal pressure and wall sub-cooling was small, but when the condensate was highly generated due to the low non-condensable gas concentration, the error was large compared to the experimental values. This is considered to be due to the nature of the condensation model of the CFX code. However, in spite of the limitations of CFD, it is valid to use the built-in condensation model of CFD for PCCS performance prediction from a conservative perspective.