References
- Chun, M. H. and Kang, M. G., 1998, 'Effects of Heat Exchanger Tube Parameters on Nucleate Pool Boiling Heat Transfer,' ASME, J. of Heat Transfer, Vol. 120, pp. 468-476 https://doi.org/10.1115/1.2824272
- Kang, M. G., 2000, 'Effect of Tube Inclination on Pool Boiling Heat Transfer,' ASME, J. of Heat Transfer, Vol. 122, Issue 1, pp. 188-192 https://doi.org/10.1115/1.521456
- Corletti, M. M. and Hochreiter, L. E., 1991, 'Advanced Light Water Reactor Passive Residual Heat Removal Heat Exchanger Test,' Proc. of the 1st JSME/ASME Joint International Conference on Nuclear Engineering, Tokyo, Japan, pp. 381-387
- 강명기, 2000, 튜브 설치방향이 풀비등 열전달에 미치는 영향, 대한기계학회 논문집 B권, 제24권, 제1호, pp. 143-151
- Kang, M. G., 1998, 'Experimental Investigation of Tube Length Effect on Nucleate Pool Boiling Heat Transfer,' Annals of Nuclear Energy, Vol. 25, No. 4-5, pp. 295 - 304 https://doi.org/10.1016/S0306-4549(97)00056-X
- Jakob, M. and Hawkins, G. A., 1957, Elements of Heat Transfer, 3rd. ed., Wiley International Edition, pp. 206-210
- van Stralen, S. J. D. and Sluyter, W. M. 1969, 'Investigations on the Critical Heat Flux of Pure Liquids and Mixtures under Various Conditions,' Int. J Heat Mass Transfer, Vol. 12, pp. 1353 -1384 https://doi.org/10.1016/0017-9310(69)90022-2
- Nishikawa, K., Fujita, Y., Uchida, S., and Ohta, H., 1984, 'Effect of Surface Configuration on Nucleate Boiling Heat Transfer,' Int. J Heat Mass Transfer, Vol. 27, No.9, pp. 1559-1571 https://doi.org/10.1016/0017-9310(84)90268-0
- Jung, D. S., Venant, 1. E. S., and Sousa, A. C. M., 1987, 'Effects of Enhanced Surfaces and Surface Orientations on Nucleate and Film Boiling Heat Transfer in R-11,' Int. J Heat Mass Transfer, Vol. 30, No. 12, pp. 2627-2639 https://doi.org/10.1016/0017-9310(87)90144-X
- Fujita, Y., Ohta, H., Uchida, S., and Nishikawa, K., 1988, ''Nucleate Boiling Heat Transfer and Critical Heat Flux in Narrow Space between Rectabgular Spaces,' Int. J of Heat Mass Transfer, Vol. 31, No.2, pp. 229-239 https://doi.org/10.1016/0017-9310(88)90004-X
- Chyu, M. C. and Mghamis, A. M., 1991, 'Nucleate Boiling on Two Cylinders in Line Contact,' Int. J Heat Mass Transfer, Vol. 34, No.7, pp. 1783-1790 https://doi.org/10.1016/0017-9310(91)90153-6
- Howard, A. H. and Mudawar, I., 1999, 'Orientation Effects on Pool Boiling Critical Heat Flux(CHF) and Modeling of CHF for Near-Vertical Surfaces,' Int. J Heat Mass Transfer, Vol. 42, pp. 1665-1688 https://doi.org/10.1016/S0017-9310(98)00233-6
- Githinji, P. M. and Sabersky, R. H., 1963, 'Some Effects of the Orientation of the Heating Surface in Nucleate Boiling,' ASME, J of Heat Transfer, Vol. 85, p. 379 https://doi.org/10.1115/1.3686129
- Cornwell, K. and Houston, S. D., 1994, ''Nucleate Pool Boiling on Horizontal Tubes: a Convection-Based Correlation,' Int. J Heat Mass Transfer, Vol. 37, Suppl. 1, pp. 303-309 https://doi.org/10.1016/0017-9310(94)90031-0