• Title/Summary/Keyword: Water load

Search Result 2,494, Processing Time 0.108 seconds

Numerical Computations of Impact Forces Acting on Breakwater Plate of Bow Deck of Container Carrier (전산유체역학을 이용한 컨테이너 선수갑판 쇄파판에 작용하는 충격하중 계산)

  • Lee, Seohyun;Lew, Jaemoon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.3
    • /
    • pp.198-205
    • /
    • 2015
  • In this study, numerical studies using a Computational Fluid Dynamics(CFD) method were carried out to estimate the green water load acting on the breakwater plate of bow deck of container carrier, KCS. For the green load water load analysis, a full load condition was considered. The relative motions at bow deck were calculated from the seakeepig analysis. Statistical analysis were carried out to estimate the long term response of the relative motions with the North Atlantic wave scatter diagram. The equivalent design wave was determined from the RAO of the relative motions at bow and the long term responses. CFD geometry modeling with three different locations and simulations for the green water loads were carried out in the equivalent design waves. A commercial CFD program, STAR-CCM+ Ver. 8.04, was used and the green water pressures on the breakwater plate were calculated successfully. The CFD analysis for green water loads can be used as a useful design tool for the evaluation of the breakwater plate of the container vessel.

Mechanical Load Performance Measurements of a Low Temperature Differential Stirling Engine with Water-Sprayed Heat Transfer according to Supply Water Flow Rates and Temperatures (스프레이 열전달을 이용한 저온도차 스털링 엔진의 고온수 공급 유량 및 온도에 따른 기계 부하성능 실험)

  • Sim, Kyuho;Jeong, Min-Seong;Lee, Yoon-Pyo;Jang, Seon-Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.1
    • /
    • pp.29-36
    • /
    • 2015
  • Recently, Stirling engines are emerging as a key device for power conversion of renewable energy or waste energy. This study develops a LTDSE(Low Temperature Differential Stirling Engine) using a water spray for higher heat transfer and performs load performance tests for various flow rates and temperatures of hot water spray for variable engine loads emulated by a mechanical friction device. Internal temperature and pressure, working frequency and inlet and outlet temperature of the supply water are measured. As a result, the increases in flow rate and temperature of hot water respectively enhance the power output, efficiency and the working frequency, while the increasing engine load leads to decreases in working frequency but increases in the pressure amplitude. Eventually, it is revealed there exists a maximum shaft power of the test engine.

Determination of Antibiotic Residues: II. Extraction and Clean-up Methods for Liquid Samples_A Review (시료 중 잔류 항생제 분석 방법: II. 액상 시료 전처리 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.628-648
    • /
    • 2016
  • Increased attention has been paid to the presence of veterinary antibiotics in various environmental matrices due to their toxicological behavior in the ecosystem and development of antibiotic-resistant strains of pathogenic bacteria. In the this review, 37 target antimicrobials were selected based on annual sales of antibiotics for livestock in South Korea 2014. Also, extraction and clean-up methods for the determination of the antibiotic residues in liquid samples including water, milk, and honey were comprehensively reviewed in the literature. Solid-phase extraction (SPE) was commonly used as a pre-treatment method for the samples. Most of the analytes were extracted in acidic conditions (2.5~4.0) except for aminoglycosides, which were extracted in neutral conditions (7.0~8.0). ${\beta}-Lactams$ showed the highest recoveries in neutral pH due to their degradation characteristics in acidic media. Starta-X, Oasis HLB, and Oasis MCX were frequently applied as an SPE cartridge and Oasis HLB showed the highest recoveries for the majority of antibiotic classes. The homogenized honey and milk were extracted by mixing with acids for deproteinization. Solids and other interfering substances in the extract were eliminated by centrifugation followed by membrane filtration or SPE before injection into HPLC.

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Applicability of Water Quality Indicators as Target Pollutants for Total Maximum Daily Loads (수질오염총량관리를 위한 대상물질 적용성 분석)

  • Park, Jun Dae;Oh, Seung Young;Park, Jae Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.531-539
    • /
    • 2013
  • In order to apply a water quality indicator as a certain target pollutant, the indicator should have the representability of an index for the management of Total Maximum Daily Loads (TMDLs). Scientific groundwork and treatment technologies also should be provided for the application of the indicator. This study analyzed the applicability of major water quality indicators for target pollutants. The results showed that four water quality indicators of TOC, T-N, SS & T-Coli can be considered as target pollutants besides existing BOD and T-P. These indicators can be applied with the preparations such as essential basic data, pollution load estimation framework as well as legal criteria setting when the need is raised. As the importance of TOC, which is considered as a replacement of BOD, is emphasized, technical and institutional terms are being prepared in order to determine TOC as another target pollutant in the near future. It could be considered to combine TOC with BOD for the time being during the $3^{rd}$ stage of TMDLs in view of the present conditions for the management of TOC. TOC can be the most effective index for the organic matter and help to be managed more systematically in the waterbodies where rivers and lakes are mutually connected.

Molecular Simulation Study on Influence of Water Film Thickness on Lubrication Characteristics (물 분자막의 두께와 윤활특성의 상관관계에 대한 분자시뮬레이션 연구)

  • Kim, Hyun-Joon;Heo, Segon
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.199-204
    • /
    • 2022
  • This paper presents a numerical investigation of the influence of water molecule thickness on frictional behavior at the nanoscale using molecular dynamics simulation. Three different models, comprising water thin films of various thicknesses, were built, and indentation and sliding simulations were performed using the models. Various normal loads were applied by indenting the Si tip on the water film for the sliding simulation to evaluate the interplay between the water thin film thickness and the normal load. The results of the simulations showed that the friction force generally increased with respect to the normal load and thickness of the water thin film. The friction coefficient varied with respect to the normal load and the water film thickness. The friction coefficient was the smallest under a moderate normal force and increased with decreasing or increasing normal loads. As the water film became thicker, the contact area between the tip and water film became larger. Under well-lubricated conditions, the friction force was proportional to the contact area regardless of the water film thickness. As the normal force increased above a critical condition, the water molecules beneath the Si tip spread out; thus, the film could not provide lubrication. Consequently, the substrate was permanently deformed by direct contact with the Si tip, while the friction force and friction coefficient significantly increased. The results suggest that a thin water film can effectively reduce friction under relatively low normal load and contact pressure conditions. In addition, the contact area between the contacting surfaces dominates the friction force.

Water quality management of Doam lake around the pasture area (목장지대 주변에 위치한 도암호의 수질관리)

  • Cho, Jae-Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.41-47
    • /
    • 1998
  • Doam Lake is located around the pasture area and Yongpyung Resort. Because of the waste load of domestic animals, nutrient concentration of the stream is high. In this study, waste load of Doam Lake watershed is calculated, and QUAL2E model is applied to the upper part of the Songcheon to calculate the input boundary concentration of Doam Lake. And WASP5 model is applied for the water quality modeling of Doam lake. The results indicate that advanced treatment of domestic animal wastes is necessary for the lake water quality management.

  • PDF

Characteristics of Runoff ratio and Pollutant Loading in Rural Watersheds (농촌유역에서의 유달부하량 및 유달율의 특성)

  • 양영민;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.533-540
    • /
    • 1998
  • In this study, to propose the methods predicting water qualities in rural areas, the methods which were based on the runoff ratio, the relationships between the pollutant load(L) and the water runoff(Q), and the relationships between the runoff ratio and the water runoff in Bokha stream watersheds were examined. As a result, we had acquired reliable the values of runoff ratio and the reasonable equations between the pollutant load(L) and the water runoff(Q) in Bokha stream watersheds. And it was noticed that the runoff ratio had tendency of varying directly proportional to the water runoff.

  • PDF

Analysis of the Difference of Flow Duration Curve according to the Cumulative Variation of the Daily Average Flow in Unit Watershed for TPLCs (총량관리 단위유역 일평균유량의 시계열 누적 변화에 따른 유량지속곡선 차이 분석)

  • Hwang, Ha-sun;Rhee, Han-pil;Seo, Ji-yeon;Choi, Yu-jin;Park, Ji- hyung;Shin, Dong-seok;Lee, Sung-jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.6
    • /
    • pp.97-109
    • /
    • 2018
  • The LDC (Load Duration Curve) method can analyze river water quality changes according to flow rate and seasonal conditions. It is also possible to visually recognize whether the target water quality is exceeded or the size of the reduction load. For this reason, it is used for the optimal reduction of TPLCs and analysis of the cause of water pollution. At this time, the flow duration curve should be representative of the water body hydrologic curve, but if not, the uncertainty of the interpretation becomes big because the damaged flow condition is changed. The purpose of this study is to estimate the daily mean flow of the unit watershed using the HSPF model and to analyze the difference of the flow duration curves according to the cumulative daily mean flow rate using the NSE technique. The results show that it is desirable to construct the flow duration curve by using the daily average flow rate of at least 5 years although there is a difference by unit watershed. However, this is the result of the water bodies at the end of Han River basin watershed, so further study on various water bodies will be necessary in the future.

Research on the Development Management Basin and Goal for 3th T.W.Q on the Boundary between Metropolitan Cities/Dos Specified in Nakdong River Basin (낙동강수계 3단계 광역시·도 경계지점 목표수질 설정을 위한 관리권역 및 관리목표 설정 방법 연구)

  • Hwang, Ha Sun;Park, Ji Hyung;Kim, Yong Seok;Rhew, Doug Hee;Choi, Yu Jin;Lee, Sung Jun
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.569-575
    • /
    • 2015
  • The current Total Pollution Load Control (TPLC) sets the Target Water Quality (TWQ) by utilizing the delivery ratio, unit loads, and water quality modeling, it also allocates the watershed's permitted discharge load. Currently, common target pollutants of every unit watershed in TPLC are BOD and T-P. This study has reviewed the 1th and 2th of TWQ setting process for the Nakdong River 3th TWQ setting in Total Pollution Load Control (TPLC). As a result of review, 1th and 2th were divided into one management basin (mulgeum) for setting management goals. However, 3th was divided into six management basins (mulgeum, gnagjeong, geumho river, nam river, miryang river, end of nakdong river). The principle of management goal setting were to achieve the objective criteria of Medium Areas for the linkage of the water environment management policy. And Anti-Degredation (principle of preventing deterioration) were applied to the 3th TWQ. Also, additional indicators were considered in accordance with the reduction scenarios for the final management goals.