• Title/Summary/Keyword: Water exchange ratio

Search Result 187, Processing Time 0.023 seconds

Isolation and Characterization of Acidic Polysaccharides Activating Complement System from the Hot Water Extracts of Pteridium aquilinum var. latiusculum (고사리 열수 추출물로부터 보체계 활성화 산성 다당의 분리 및 특성)

  • O, Byeong-Mi;Gwon, Mi-Hyang;Na, Gyeong-Su
    • The Korean Journal of Food And Nutrition
    • /
    • v.7 no.3
    • /
    • pp.159-168
    • /
    • 1994
  • From the hot water extract of bracken(Pteridium aquilinum var. latiusculum), a Korean win edible plant, anti-complementary acidic polysaccharides were Isolated. Crude polysaccharide fraction(HPA-1) was obtain ed by methanol reflux, ethanol precipitation, dialysis, and lyophilization. HPA-1 contained 81.80% of total sugar, 30.40% of uronic acid, and 15.60cA of protein. HPA 1 was purified consecutively by cetavlon fractionation and chromatography including ion exchange nth DEAE-Sepharose CL 6B and gel permeation with Sephadex G-100 and Sepharose CL-6B. HPA-2- IVa and HPA-Va-2 were nearly homogeneous on HPLC and had 500,000 and 560,000 daltons of molecular weights, respectively. HPA-2-Wa consisted of fucose, galacturonic acid, and glucuronic acid at the molar ratio of 1.40 : 0.97 : 1.88. HPA-2-Va 2 was composed of rhamnose, galactose, and galacturonic acid at the molar ratio of 1.00 : 1.38 : 1.39. The polysaccharides were found to activate the C3 component both In the presence and In the absence of Ca2+ through the crossed-immunoelectrophoresis suggesting that those Involved in both classical and alternative complement pathway.

  • PDF

Studies on the Preparation of Anion Exchange Membrane through Blending of the Poly(ethylenimine) and the Poly(vinyl alcohol) (폴리비닐알코올과 폴리에틸렌이민과의 혼합을 통한 음이온교환막의 제조 연구)

  • Kim, Sung-Pyo;Kim, Baek-Kyun;Lee, Hak-Min;Rhim, Ji-Won;Jeong, Sung-Il
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.335-341
    • /
    • 2010
  • This study focuses on the investigation of the anion exchange membrane through blending poly(ethylenimine) (PEI) and poly(vinyl alcohol) (PVA) varying the mixing ratio. To characterize the resulting membranes, the water content, contact angle, FT-IR, thermal gravimetric analysis, ion exchange capacity, ion conductivity and elastic modulus were measured. The PVA / PEI = 90 / 10 membrane showed the ion conductivity, $5.16{\times}10^{-2}S/cm$ and simultaneously the contact angle, $78.3^{\circ}$. According to TGA measurement, the resulting membranes seemed durable at room temperature. Through the modulus test, the mechanical properties increased with increasing PVA content and apparently the membranes looked very robust.

Preparation and Characterization of Poly(Arylene Ether) Having Heterocyclic Quaternary Ammonium Functional Groups for Anion Exchange Membranes (음이온교환막용 헤테로고리형 4차 암모늄 작용기를 갖는 폴리(아릴렌 이써)의 제조 및 특성 분석)

  • LEE, SANG HYEOK;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.372-382
    • /
    • 2022
  • In this study, anion exchange membranes were prepared by synthesizing the main chain into a poly(arylene ether) (PAE) structure, and the structures capable of improving the physical and chemical stability of the membrane by introducing a heterocyclic quaternary ammonium functional groups were studied. The chemical structure and thermal properties of the prepared polymer were confirmed by 1H-NMR, FT-IR, TGA, and DSC, and surface analysis was performed through AFM measurement. Additionally, dimensional stability and chemical properties was studied by measuring water uptake and swelling ratio, IEC and ionic conductivity. At 90℃, the quaternized poly(arylene ether) (QPAE)/1-methylpiperidine (MP) membrane exhibited the highest ionic conductivity of 27.2 mS cm-1, while the QPAE/1-methylimidazole (MI) membrane and QPAE/1-methylmorpholine (MM) membrane exhibited values of 14.5 mS cm-1 and 11.5 mS cm-1, respectively. In addition, the prepared anion exchange membrane exhibited high chemical stability in alkaline solution.

Simultaneous Improvement of Dimensional Stability and Ionic Conductivity of QPAE/TiO2-x Composite Membranes According to TiO2 Content Control for Anion Exchange Membrane Fuel Cells (음이온교환막 연료전지를 위한 TiO2 함량 조절에 따른 QPAE/TiO2-x 복합막의 치수안정성 및 이온전도도 동시 개선 연구)

  • KIM, SANG HEE;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.19-27
    • /
    • 2022
  • A series of QPAE/TiO2-x (x = 1, 4, 7 and 10 wt%) organic/inorganic composite membranes were prepared as electrolyte membranes for alkaline anion exchange membrane fuel cells by controlling the content of inorganic filler with quaternized poly(arylene ether) (QPAE) random copolymer. Among the prepared QPAE/TiO2-x organic/inorganic composite membranes, the highest ionic conductivity was 26.6 mS cm-1 at 30℃ in QPAE/TiO2-7 composite membrane, which was improvement over the ionic conductivity value of 6.4 mS cm-1 (at 30℃) of the pristine QPAE membrane. Furthermore, the water uptake, swelling ratio, ionic exchange capacity, and thermal property of QPAE/TiO2-x composite membranes were improved compared to the pristine QPAE membrane. The results of these studies suggest that the fabricated QPAE/TiO2-x composite membranes have good prospects for alkaline anion exchange membrane fuel cell applications.

Thermally Stratified Hot Water Storage (태양열의 성층축열과 주택이용에 관한 연구(성층축열))

  • Pak, Ee-Tong
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.3-12
    • /
    • 1990
  • This paper deals with experimental research to increase thermal storage efficiency of hot water stored in an actual storage tank for solar application. The effect of increased energy input rate due to stratification has been discussed and illustrated through experimental data, which was taken by changing dynamic and geometric parameters. Ranges of the parameters were defined for flow rate, the ratio of diameter to height of the tank and inlet-exit water temperature difference. During the heat storage, when the flow was lower, the temperature difference was larger and the ratio of diameter to height of the tank was higher, the momentum exchange decreased. As for this experiment, when the flow rate was 8 liter/min, the temperature difference was $30^{\circ}C$ and the ratio of diameter to height of the tank was 3, the momentum exchange was minimized resulting in a good thermocline and a stable stratification. In the case of using inlet ports, if the modified Richardson number was less than 0.004, full mixing occured and so unstable stratification occured, which mean that this could not be recommended as storage through thermal stratification. Using a distributor was better than using inlet ports to form a sharp thermocline and to enhance the stratification. It was possible to get storage efficiency of 95% by using the distributor, which was higher than a storage efficiency of 85% obtained by using inlet ports in same operation condition. Furthermore, if the distributor was manufactured so that the mainpipe decreases in diameter toward the dead end to maintain constant static pressure, it might be predicted that further stable stratification and higher storage efficiency are obtainable(ie:more than 95%).

  • PDF

Signal processing method based on energy ratio for detecting leakage of SG using EVFM

  • Xu, Wei;Xu, Ke-Jun;Yan, Xiao-Xue;Yu, Xin-Long;Wu, Jian-Ping;Xiong, Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1677-1688
    • /
    • 2020
  • In the sodium-cooled fast reactor, the steam generator is a heat exchange device between sodium and water, which may cause leakage, resulting in a sodium-water reaction accident, which in turn affects the safe operation of the entire nuclear reactor. To this end, the electromagnetic vortex flowmeter is used to detect leakage of the steam generator and its signal processing method is studied in this paper. The hydraulic experiment was carried out by using water instead of liquid sodium, and the sensor output signal of the electromagnetic vortex flowmeter under different gas injection volumes was collected. The bubble noise signal is reflected by the base line of the sensor output signal. According to the relationship between the proportion of the bubble noise signal in the sensor output signal and the gas injection volume, a signal processing method based on the energy ratio calculation is proposed to detect whether the water contains bubbles. The gas injection experiment of liquid sodium was conducted to verify the effectiveness of the signal processing method in the detection of bubbles in sodium, and the minimum detectable leak rate of water in the steam generator was detected to be 0.2 g/s.

Nitrogen Dynamics and Growing of Shrimp (Fenneropenaeus chinensis) in the High Density Aquaculture Ponds (고밀도 축제식 양식장의 질소역학과 대하 (Fenneropenaeus chinensis) 성장)

  • KANG Yun Ho;YOON Yang Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.1
    • /
    • pp.24-32
    • /
    • 2004
  • A mathematical model is used to investigate nitrogen dynamics in the intensive aquaculture ponds in the western coast of Korea. Parameters associated with water quality, sediments and growing of shrimp (Fenneropenaeus chinensis) are measured to calibrate the model for feeding ponds A and B and storage ponds. The model describes the fate of nitrogen including loadings of ammonia from feeds, phytoplankton assimilation, nitrification, sedimentation, volatilization and discharge. The model obtains good agreements with the measured values of TAN $(NH_4,\;NH_3),\;NO(NO_2,\;NO_3)$ and Chl (chlorophyll a). Impacts of water exchange on TAN and Chl are investigated, showing that the range of 0.01-0.2 (/day) cannot effectively reduce TAN but reduces Chl. Nitrogen in the ponds A is removed by sedimentation $66\%,$ volatilization $8\%,$ discharge of particulate and dissolved $8\%.$ The pond B shows $56\%\;and\;26\%$ of sedimentation and volatilization, respectively, to yield $10\%.$ decrease and 8c/o increase compared to those in the pond A. While the pond A has larger area (1.02:0.66 ha) and same stocking density (0.025 md./L) at the beginning of culture, the pond B obtains higher stocking density (0.0065:0.0091 md./L), longer feeding period (103:121 day) and resultant higher shrimp production (1.15:2.13 t/ha/cycle) at harvest. This is possibly due to the hydraulic characteristics driven by paddlewheels. At low ratio of the low speed area and the pond area, the rate of sedimentation is high, while the rate of gas exchange is low. Thus, the measurement and model analysis suggest that water quality and shrimp production are positively correlated with the hydraulic characteristics in the shrimp ponds.

Cellulose Nanocrystals Incorporated Poly(arylene piperidinium) Anion Exchange Mixed Matrix Membranes (셀룰로오스 나노 결정을 도입한 폴리아릴렌 피페리디늄 음이온 교환 복합매질분리막)

  • Da Hye Sim;Young Park;Young-Woo Choi;Jung Tae Park;Jae Hun Lee
    • Membrane Journal
    • /
    • v.34 no.2
    • /
    • pp.154-162
    • /
    • 2024
  • Anion exchange membranes (AEMs) are essential components in water electrolysis systems, serving to physically separate the generated hydrogen and oxygen gases while enabling the selective transport of hydroxide ions between electrodes. Key characteristics sought in AEMs include high ion conductivity and robust chemical and mechanical stability in alkaline. In this study, quaternized Poly(terphenyl piperidinium)/cellulose nanocrystals (qPTP/CNC) mixed matrix membrane was fabricated. The polymer matrix, PTP, was synthesized via super-acid polymerization, known for its excellent ion conductivity and alkaline durability. The qPTP/CNC membrane showed a dense and uniform morphology without significant voids or large aggregates at the polymer-nanoparticle interface. The qPTP/CNC membrane containing 2 wt% CNC demonstrated a high ion exchange capacity of 1.90 mmol/g, coupled with low water uptake (9.09%) and swelling ratio (5.56%). Additionally, the qPTP/CNC membrane showed significantly lower resistance and superior alkaline stability (384 hours at 50℃ in 1 M KOH) compared to the commercial FAA-3-50 membrane. These results highlight the potential of hydrophilic additive CNC in enhancing ion conductivity and alkaline durability of ion exchange membranes.

Relationship Analysis between Half Cell Potential and Open Circuit Potential Considering Temperature Condition (온도 영향을 고려한 RC 구조의 반 전위 및 OCP의 상관성 분석)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.124-132
    • /
    • 2022
  • The corrosion potential in concrete varies greatly with exposure and concrete mix conditions. In this study, RC (Reinforcement Concrete) samples were prepared considering cover depth, chloride concentration, and W/C(water to cement) ratio as variables, and HCP(Half Cell Potential) was measured, which evaluated comparative potential between embedded steel and concrete surface. In addition, OCP(Open Circuit Potential) was measured using buried steel and CE(Counter Electrode). Agar and NaOH solution were used as ion exchange materials and Hg/HgO was used for RE(Reference Electrode), which was more sensitive to temperature than HCP. Among the influencing factors, the exposure period and chloride concentration had a relatively greater effect than cover depth and w/c ratio. Additionally, the entire measured HCP and OCP showed a clearly linear relationship with increasing cover depth and w/c ratio. Through multiple regression analysis, the relationship between HCP and OCP was quantified, and an improved correlation was obtained with temperature effect.

Characteristics of Persistent of Hexachlorocyclohexane(HCH) in Ambient Air-Soil-Water-Sediment for a Emerging Persistent Organic Pollutants(POPs) (신규 잔류성 유기오염물질(Emerging Persistent Organic Pollutants E-POPs) 핵사클로로시클로핵산(HCH)의 대기-토양-물-저질에서의 잔류특성)

  • Hwang, Sung-Min;Lee, Seok-Hyung;Park, No-Jin;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1343-1354
    • /
    • 2010
  • The purpose of the study was to analyze the persistence of HCH in atmosphere, soil, sediment and water of the western and southern regions of Korea. The samples from the western region were collected from Anmyeon Island, and the samples from the southern region were collected from Kimhae and Busan. The concentration of HCH isomers in atmosphere showed the pattern of $\alpha$-HCH>$\gamma$-HCH>$\beta$-HCH. The regions with high HCH concentration in the atmosphere are the regions that have been highly exposed to HCH used in the past, and the areas that have been influenced by the long range transport. The HCH that persists in the soil, water and sediment evaporates into the atmosphere, showing the characteristics of Air-Surface exchange. When the regional concentration distributions are compared, the concentration of HCH was higher in the atmosphere of a plain and the cities near the plain, than the urban areas. In this study, the ratio of $\alpha/\beta$-HCH was used as an indicator for estimating the source of Technical HCH and Lindane. According to the result, the contribution of Lindane was high in Kimhae plain and Kimhae urban areas. However, in Busan, the contribution of Technical HCH was higher than Lindane. In case of Anmyeon Island, the western region of Korea had high contribution from Tehcnical HCH. In soil and sediment, $\beta$-HCH was dominant. In water, $\gamma$-HCH was dominant among other isomers. Such results are due to $\gamma$-HCH inLindane. Furthermore, the source of $\gamma$-HCH in urban areas is assumed to be the use of medicine, medical supplies and other living supplies. Based on the results of this study, the management of HCH, a newly list up emerging POPs, should be strengthened by further research on sources, fate, persistency, accumulation and exposures and etc. to the risk assessments.