Browse > Article
http://dx.doi.org/10.14190/JRCR.2022.10.1.124

Relationship Analysis between Half Cell Potential and Open Circuit Potential Considering Temperature Condition  

Yoon, Yong-Sik (Department of Civil and Environmental Engineering, Hannam University)
Kwon, Seung-Jun (Department of Civil and Environmental Engineering, Hannam University)
Publication Information
Journal of the Korean Recycled Construction Resources Institute / v.10, no.1, 2022 , pp. 124-132 More about this Journal
Abstract
The corrosion potential in concrete varies greatly with exposure and concrete mix conditions. In this study, RC (Reinforcement Concrete) samples were prepared considering cover depth, chloride concentration, and W/C(water to cement) ratio as variables, and HCP(Half Cell Potential) was measured, which evaluated comparative potential between embedded steel and concrete surface. In addition, OCP(Open Circuit Potential) was measured using buried steel and CE(Counter Electrode). Agar and NaOH solution were used as ion exchange materials and Hg/HgO was used for RE(Reference Electrode), which was more sensitive to temperature than HCP. Among the influencing factors, the exposure period and chloride concentration had a relatively greater effect than cover depth and w/c ratio. Additionally, the entire measured HCP and OCP showed a clearly linear relationship with increasing cover depth and w/c ratio. Through multiple regression analysis, the relationship between HCP and OCP was quantified, and an improved correlation was obtained with temperature effect.
Keywords
HCP; OCP; Cover depth; Chloride concentration; Temperature; Water to cement ratio;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Maierhofer, C., Arndt, R., Rollig, M., Rieck, C., Walther, A., Scheel, H., Hillemeier, B. (2006). Application of impulse-thermography for nondestructive assessment of concrete structures, Cement and Concrete Composites, 28(4), 393-401.   DOI
2 Permeh, S., Lau, K., Lasa, I., Paredes, M. (2015). "Material and corrosion evaluation of defficient PT grout with enhanced sulfate concentrations," NACE Corrosion 2015, NACE CORROSION, Houston, TX, USA, 5828.
3 Shao, X.M., Feldman, J.L. (2007). Micro-agar salt bridge in patch-clamp electrode holder stabilizes electrode potentials, Journal of Neuroscience Methods, 159(1), 108-115.   DOI
4 Tsai, Y.H., Wang, J., Chien, W.T., Wei, C.Y., Wang, X., Hsieh, S.H. (2019). A BIM-based approach for predicting corrosion under insulation, Automation in Construction, 107, 102923.   DOI
5 Li, F., Yuan, Y., Li, C.Q. (2011). Corrosion propagation of prestressing steel strands in concrete subject to chloride attack, Construction and Building Materials, 25(10), 3878-3885.   DOI
6 Lee, S.K., Zielske, J. (2014). An FHWA special study: post-tensioning tendon grout chloride thresholds, Federal Highway Administration, FHWA-HRT-14-039.
7 Kim, Y.Y., Kim, J.M., Bang, J.W., Kwon, S.J. (2014). Effect of cover depth, w/c ratio, and crack width on half cell potential in cracked concrete exposed to salt sprayed condition, Construction and Building Materials, 54(15), 636-645.   DOI
8 KIBSE. (2020). Investigation and Monitoring Academic Service for Inner Ring Road PSC Box Girder Bridge Tendon - Final Report, Korean Institute of Bridge and Structural Engineers, Seoul [in Korean].
9 Baek, S.H., Xue, W., Feng, M.Q., Kwon, S.J. (2012). Nondestructive corrosion detection in RC through integrated heat induction and IR thermography, Journal of Non Destructive Evaluation, 31(2), 181-190.
10 Chung, L., Kim, J.H.J., Yi, S.T. (2008). Bond strength prediction for reinforced concrete members with highly corroded reinforcing bars, Cement and Concrete Composites, 30(7), 603-611.   DOI
11 Karthick, S.P., Muralidharan, S., Saraswathy, V., Thangavel, K. (2014). Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures, Sensor and Actuators B: Chemical, 192, 303-309.   DOI
12 Broomfield, J.P. (1997). Corrosion of Steel in Concrete: Understanding, Investigation and Repair, E&FN, London, 1-15.
13 Ishida, T., Iqbal, P.O., Anh, H.T.L. (2009). Modeling of chloride diffusivity coupled with non-linear binding capacity in sound and cracked concrete, Cement and Concrete Research, 39(10), 913-923.   DOI
14 Kwon, S.J., Na, U.J., Park, S.S., Jung, S.H. (2009). Service life prediction of concrete wharves with early-aged crack: probabilistic approach for chloride diffusion, Structural Safety, 31(1), 75-83.   DOI
15 Karthick, S.P,, Kwon, S.J., Lee, H.S., Muralidharan, S., Saraswathy, V., Natarajan, R. (2017). Fabrication and evaluation of a highly durable and reliable chloride monitoring sensor for civil infrastructure, RSC advances, 7(50), 31252-31263.   DOI
16 Park, S.S., So, B.T. (2016). A study on correlation between accelerated corrosion test and long-term exposure test according to the temperature condition, Journal of Recycled Construction Resources, 4(2), 203-208 [in Korean].
17 Yang, K.H., Lim, H.S., Kwon, S.J., Kim, J.H. (2020). Repair cost estimation techniques for reinforced concrete structures located at the seashore: Considering various probabilistic service life functions and actual mix proportions, Construction and Building Materials, 256, 119469.   DOI
18 Lee, S.S., Kwon, S.J. (2021). Characteristics of OCP of reinforced concrete using socket-type electrodes during periodic salt damage test, Journal of the Korea Institute for Structural Maintenance and Inspection, 25(4), 28-36 [in Korean].   DOI
19 Matsumura, T., Shirai, K., Saegusa, T. (2008). Verification method for durability of reinforced concrete structures subjected to salt attack under high temperature conditions, Nuclear Engineering and Design, 238(5), 1181-1188.   DOI
20 Maekawa, K., Ishida, T., Kishi, T. (2009). Multi-Scale Modeling of Structural Performance, Taylor Fr, London, 322-325.
21 Song, H.W., Saraswathy, V. (2006). Studies on the corrosion resistance of reinforced steel in concrete with ground granulated blast-furnace slag-an overview, Journal of Hazardous Materials, 138(2), 226-233.   DOI
22 Win, P.P., Watanabe, M., Machida, A. (2004). Penetration profile of chloride ion in cracked reinforced concrete, Cement and Concrete Research, 34(7), 1073-1079.   DOI
23 Alonso, C., Andrade, C., Gonzalez, J.A. (1988). Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types, Cement and Concrete Research, 18(5), 687-698.   DOI
24 Adams, R.D., Cawley, P. (1989). Defect types and non destructive testing techniques for composites and bonded joints, Construction and Building Materials, 3(4), 170-183.   DOI
25 Andrade, C., Alonso, C. (1996). Corrosion rate monitoring in the laboratory and on-site, Construction and Building Materials, 10(5), 315-328.   DOI
26 So, H.S., Choi, S.H., Seo, C.S., Seo, K.S., So, S.Y. (2014). Influence of temperature on chloride ion diffusion of concrete, Journal of the Korea Concrete Institute, 26(1), 71-78 [in Korean].   DOI
27 Thomas, M.D., Bamforth, P.B. (1999). Modelling chloride diffusion in concrete: effect of fly ash and slag, Cement and Concrete Research, 29(4), 487-495.   DOI
28 Yoon, Y.S., Ryu, H.S., Lim, H.S., Koh, K.T., Kim, J.S., Kwon, S.J. (2018). Effect of grout conditions and tendon location on corrosion pattern in PS tendon in grout, Construction and Building Materials, 186, 1005-1015.   DOI
29 Duffo, G.S., Farina, S.B., Giordano, C.M. (2009). Characterization of solid embeddable reference electrodes for corrosion monitoring in reinforced concrete structures, Electrochimica Acta, 54(3), 1010-1020.   DOI
30 Dhir, R.K., Jones, M.R., Elghaly, A.E. (1993). PFA concrete: exposure temperature effects on chloride diffusion, Cement and Concrete Research, 23(5), 1105-1114.   DOI