• Title/Summary/Keyword: Waste quality

Search Result 1,137, Processing Time 0.028 seconds

Assessment of Practical Use of Recycling Oil from the Pyrolysis of Mixed Waste Plastics (혼합폐플라스틱의 열분해를 통한 회수오일의 이용가능성 평가)

  • Phae Chae-Gun;Kim Young-shin;Jo Chang-Ho
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.159-166
    • /
    • 2005
  • In Korea, although the generation of waste plastic has been increasing, the rate of recycling is considerably low and moreover, there is no suitable method for the treatment of waste plastics. However, pyrolysis, which is appropriate for the treatment of highly polymerized compounds, such as plastics, has recently gained much interest. In this study, a property of the products from the pyrolysis of mixed waste plastics, with a possible practical use for the recycling oil produced, were assessed. First of all, in order to investigate the pyrolysis characteristic of waste plastics, TGA (Thermogravimetric analysis) and DCS (Differential Scanning Calorimetry) were performed on a number of different plastics, including PP, LDPE, HDPE, PET and PS, as well as others. According to the result, it appeared that PP was the most efficiently pyrolyzed by changing the temperature, followed by LDPE, HDPE, PET, PS and the other plastics, in that order. From the results, the optimum conditions f3r pyrolysis were set up, and the different waste plastics pyrolyzed. The recycling oil produced from the flammable gases generated during the pyrolysis was com-pared with fuel oil by an analysis using the petroleum quality inspection method on KS(Korea industrial Standard). The results of the analysis showed the recycling oil was of a similar standard to fuel oil, with the exception of the ignition point, with a quality somewhere between that of paraffin oil and diesel fuel. With respect to these results, the quality of the recycling oil produced by the pyrolysis of waste plastics was suf-ficient for use as fuel oil.

The assessment of self cleaning velocity and optimal flushing velocity in water distribution system (상수관망의 자가세척 유속과 적정 플러싱 유속 평가)

  • Bae, Cheol-Ho;Choi, Doo Yong;Kim, Ju-Hwan;Kim, Do-Hwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.

Real time detection algorithm against illegal waste dumping into river based on time series intervention model (시계열 간섭 모형을 이용한 불법 오물 투기 실시간 탐지 알고리즘 연구)

  • Moon, Ji-Eun;Moon, Song-Kyu;Kim, Tae-Yoon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.5
    • /
    • pp.883-890
    • /
    • 2010
  • Illegal waste dumping is one of the major problems that the government agency monitoring water quality has to face. One solution to this problem is to find an efficient way of managing and supervising the water quality under various kinds of conditions. In this article we establish WQMA (water quality monitoring algorithm) based on the time series intervention model. It turns out thatWQMA is quite successful in detecting illegal waste dumping.

An Experimental Study of the Recycled Cement Manufacturing Method for Improving the Material Quality (재생시멘트의 품질향상을 위한 제조방법에 관한 연구)

  • Oh, Sang-Gyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.2
    • /
    • pp.143-149
    • /
    • 2004
  • The recycle of domestic waste concrete is, however, still in an early stage, and it has been only partially being used for the road fillers. As a counter-plan of activating recycled concrete, we have confirmed the hydration possibility of the waste concrete powder from the experiment on recycling the aggregate powder since 2000. Though that study, we have known that the strength is increasing when the baking time is longer, and baking temperature maintain in $700^{\circ}C$. Also, the quality is lowered because of the fine aggregate powder which has a bad influence on flowability & compression strength by adhesion of mortar on the aggregate face. Therefore, mortar and interfacial separation of aggregate are large in proper quality for concrete recycling is expected that affect. The purpose of this study is to investigate effective aggregate separation and to determine the most suitable production method controlling the duration of baking time for recycled cement from the compressive strength, X-ray diffraction and ingredient analysis test.

Comprehensive Review of the Evolution and Key Amendments in the 16th Regulation on Quality Certification and Management of Recycled Aggregate (순환골재 품질인증 및 관리에 관한 규칙 16차 개정연혁 및 개정내용에 대한 고찰)

  • Jeon, Soo-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.739-750
    • /
    • 2023
  • The quality certification for recycled aggregate is governed by the Construction Waste Recycling Promotion Act, overseen by the Ministry of Environment. The specific criteria for this certification are detailed in the Regulations on Quality Certification and Management of Recycled Aggregate, a mandate of the Ministry of Land, Infrastructure, and Transport. These regulations were initially enacted on April 10, 2006, and have undergone a total of 16 revisions to date, the most recent being on December 23, 2021. This paper delves into the revision history of these pivotal regulations pertaining to quality certification over the past 17 years, with a particular focus on the latest revision, which encompasses significant changes, including those in follow-up management. This analysis aims to aid stakeholders in the recycled aggregate sector, including 402 certified companies, in comprehensively understanding the government's strategic direction for quality certification and to encourage the recycling of construction waste by bolstering the quality certification process.

Assessment on Stabilization of Open-dumping Landfill Based on Leachate - A Case Study of Salmi Landfill - (침출수 특성 분석을 통한 사용종료 비위생매립지 안정화 평가 - 살미매립지 사례연구 -)

  • Hong, Sang-Pyo;Kim, Kwang-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.5
    • /
    • pp.299-308
    • /
    • 2006
  • To utilize a closed municipal solid waste landfill site in environmentally secure conditions, it is necessary to verify the stabilization level of landfill leachate. To assess leachate stabilization of an open-dumping municipal solid waste landfill site (Salmi Landfill) which is located at the vicinity of Chungju Reservoir which flows into Paldang Reservoir utilized as Seoul Metropolitan water supplies, the landfill history and surrounding characteristics of the landfill site were surveyed. In this investigation, waste, leachate, groundwater and surfacewater samples from this landfill were physically and chemically analyzed, and the analysis results were evaluated by 'The Criteria of Landfill Waste Stabilization (CLWS)', 'Discharge Criteria of Landfill Leachate', 'The Criteria of Domestic Use in Groundwater Quality', and 'The Criteria of Domestic Use in Surfacewater Quality' that promulgated by Korean Ministry of Environment. From the analysis results on the Salmi open-dumping landfill, C/N ratio was 18.9 and $BOD/COD_{Cr}$ ratios in leachate were higher than 1/10. Based on the CLWS, this results seemed to imply that the process of leachate stabilization at this landfill was still proceeding.

Operating Characteristics of Composting Facility during Composting of Food Waste and Co-composting of Food Waste and Sewage Sludge (음식물쓰레기 단독 퇴비화 및 음식물쓰레기와 하수 슬러지의 혼합 퇴비화에 따른 퇴비화시설의 운전특성)

  • 남궁완;이노섭;박준석;인병훈;허준무;박종안
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.86-92
    • /
    • 2002
  • This study was performed to assets the operating characteristics of food waste composting and co-composting (food waste + sewage sludge) at a compelling facility. The facility was being operated successfully without being affected by kind of composting feed materials. Partial anaerobic condition was detected during food waste composting and co-com-posting, but these two composting systems were proven to be operated successfully under aerobic condition from the monitoring results of $O_2$, volatile solids reduction rate, temperature, and other parameters. The conductivity and chloride concentrations of compost were gradually increased during two composting periods, but the conductivity and chloride concentrations of co-compelling indicated lower values than those of food waste composting at final point(40 m). As a result, co-composting was turned out to be more desirable than food waste composting, considering salt problem. High correlations ($R^2$= 0.9265 for food waste composting and $R^2$= 0.9685 for co-composting) between CEC and volatile organic matter were found. Quality of composts produced from two composting process satisfied Korean heavy metal standard.

Physicochemical Characteristics of Waste Catalyst and Their In-Process Products from Recycling (폐촉매 및 재활용 중간생성물의 물리화학적 특성 평가)

  • Park, Joon-Seok;Jeun, Byung-Do;Kim, Joung-Dae
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.2
    • /
    • pp.150-158
    • /
    • 2011
  • This research was conducted to estimate the physicochemical characteristics of waste catalyst and its in-process product from recycling and to suggest fundamental data for religious systems such as quality standards. Mo and V contents were increased from the waste catalyst to calcinated material and oxidized material. In the results of a heavy metals leaching test, Pb was not detected in any catalyst, calcinated and oxidized materials. Cu was not detected in the catalyst. However, it was detected in ${\leq}$1.16 mg/l for calcinated material and in 1.34~13.73 mg/l for $MoO_3$ oxidezed material. Concentrations in recycling in-process products (calcinated and oxidized materials) were higher than those of waste catalyst. Oil content of catalyst waste ranged from 0.01-14.03 wt%. Oil contents of calcinated and oxidized materials were greatly decreased compared to the catalyst waste. Carbon and sulfur contents as chemical poisoning material of catalyst waste ranged from 0.33-76.08 wt% and 5.00-22.00 wt%, respectively. The carbon contents of calcinated and oxidized materials showed below 20 wt%. The sulfur content showed below 8wt% for calcinated material and below 0.22 wt% for oxidized material.

An Experimental Study on the Properties of Lightweight Foamed Concrete According to the Replacement Ratio and Particle Size of Waste Concrete Powder (폐콘크리트 미분말 대체율 변화와 입도 변화에 따른 경량기포콘크리트의 특성에 관한 실험적 연구)

  • Lee, Dae Geun;Han, Sang Il;Park, Hyo Jin;Kang, Cheol;Kang, Ki Woong;Kim, Jin Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.121-125
    • /
    • 2009
  • The recycling of waste concrete is increasing for the environment protection and the shortage of aggregate according to the large scale construction project in Korea. The more manufacturing high quality recycled aggregate is produced, the more waste concrete powder generated from the manufacture process of recycled aggregate, and the consideration about the recycling of waste concrete powder is need. Waste concrete powder was used for the partial replacement of silica powder, which is a main raw material for the manufacture of autoclave foamed concrete. According to the results of research, the slurry density, flow, compressive strength mainly depend on the replacement ratio of particle size and waste concrete powder. At the SEM analysis, the more high-waste concrete powder was the less there are generated tobermorite. But we conclude that it is possible to replace WCP as silica source in the manufacture of the lightweight foamed concrete.

  • PDF