• Title/Summary/Keyword: Wall Voltage

Search Result 206, Processing Time 0.028 seconds

Determination of Optimal Electrotransformation Conditions for Various Lactobacillus spp. (다양한 Lactobacillus 균주에 대한 electrotransformation 최적 조건 탐색)

  • Lee, Yoo-Won;Im, Sung-Hoon;Xin, Chun-Feng;So, Jae-Seong
    • KSBB Journal
    • /
    • v.24 no.2
    • /
    • pp.182-188
    • /
    • 2009
  • Lactobacillus spp., primary members of probiotics, have significant benefits for health and well-being of human. In this study Lactobacillus strains representing six species (L. paracasei KLB58, L. fermentum MS79 and KLB282, L. plantarum KLB213, L. gasseri KLB238, and L. reuteri KLB270) isolated from Korean adults were electrotransformed with plasmid pNCKH104. To determine optimal electrotransformation conditions, various conditions including cell wall weakening agent, electroporation buffer, electric field strength and time constant were tested for each strain. Overall, high transformation efficiency of approximately 2.5 ${\times}$ $10^3$ ${\sim}$ 5.5 ${\times}$ $10^4$ CFU/${\mu}g$ DNA was obtained where conditions of 0.5 M sucrose electroporation buffer, 1.8 kV pulse voltage and 5 ms time constant were applied. The common conditions developed in this study will make transformation of various Lactobacillus spp. easier than previous procedures.

The Usefulness of Bone Scan in Electric Burns (전기화상에서 골스캔의 유용성)

  • Kim, Tae-Hyung;So, Yong-Seon;Kweon, Ki-Hyeon;Han, Sang-Woong;Kim, Seok-Hwan;Kim, Jong-Soon;Han, Seung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.130-138
    • /
    • 1996
  • Bone scan is known to be an effective tool for observing the state of soft tissues and bones of electric burn patients. It is also used for observing the progress of patients after debridement or skin graft as well as deforming to amputate specific body parts. To evaluate bone scan's role in electric burn, we analyzed bone scan 37 patients with electric burn. Among the 37 patients, 8 of 37 were injured in low voltage and 29 of them in high voltage. 27 patients received the electrical input through the hand, 6 through the scalp, 2 through the shoulder, 1 through the left chest wall and 1 through the left inguinal area. Among 29 patients received high voltage, 22 patients had the electrical output through the foot, 3 through the hand, 2 through the shoulder, 1 through the buttock and 1 through the left chest wall. Bone scans revealed cellulitis in 37 patients with 47 sites, osteomyelitis in 15 patients with 15 sites & bone defects in 4 patients with 4 sites. In 4 patients with skin graft or skin flap, follow up bone scan showed improvements of bony uptake in preoperatively bony defect area and all of them were healed without complication. There were 2 cases in which uptake increased in the myocardium, 1 in the liver and 6 in the kidney, however, serum calcium level, EKG, cardiac enzyme, liver and renal function tests were normal. In conclusion, bone scans are helpful in the assessment of injury sites after electrical insult and in differential diagnosis of cellulitis and osteomyelitis. It is also useful tool of assessment after skin graft or skin flap, however, it should be further evaluated about internal organ damage.

  • PDF

Growth of $CuGaSe_2$ single crystal thin film for solar cell development and its solar cell application (태양 전지용 $CuGaSe_2$ 단결정 박막 성장과 태양전지로의 응용)

  • Yun, Suk-Jin;Hong, Kwang-Joon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.6
    • /
    • pp.252-259
    • /
    • 2005
  • Single crystal $CuGaSe_2$ layers were grown on thoroughly etched semi-insulating CaAs(100) substrate at $450^{\circ}C$ with hot wall epitaxy (HWE) system by evaporating $CuGaSe_2$ source at $610^{\circ}C$. The crystalline structure of the single crystal thin films was investigated by the photoluminescence (PL) and double crystal X-ray diffraction (DCXD). The carrier density and mobility of single crystal $CuGaSe_2$ thin films measured with Hall effect by Van der Pauw method are $4.87{\times}10^{17}cm^{-3}$ and $129cm^2/V{\cdot}s$ at 293 K, respectively. The temperature dependence of the energy band gap of the $CuGaSe_2$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=1.7998eV-(8.7489{\times}10^{-4}eV/K)T^2/(T+335K)$. The voltage, current density of maxiumun power, fill factor, and conversion, efficiency of $n-CdS/p-CuGaSe_2$, heterojunction solar cells under $80mW/cm^2$ illumination were found to be 0.41 V, $21.8mA/cm^2$, 0.75 and 11.17%, respectively.

Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles (환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I))

  • Oh, Pil Jae;Park, Tae Soon;Lee, Min Kie;Kim, Kyung Hwa
    • Analytical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.262-269
    • /
    • 1996
  • The muiltiwire proportional counter for the measurement of low-level and environmental $\alpha$ particles emitting nuclides was developed. External dimension of the devloped multiwire proportional counter is $350{\times}290{\times}30mm$ and the sensitivity area is $250{\times}200mm$. The wall material of the detector was selected the stainless steel to prevent the deformation by external impact and to obtain minimum background. The anode and cathode wires were used the stainless steel material of diameter $50{\mu}m$. The spacing of each wires are 10.0mm, 5.0mm and the numbers of total wire are 21, 42 lines, respectively. The multiwire proportional counter was designed that the measurement source is placed within the detector to prevent the wall absorption effect and the efficiency variation by various source heights. The characteristics of the developed detector have been investigated to obtain the plateau, operating voltage, background, counting efficiency, position sensitivity and energy resolution etc. For the $^{241}Am$ nuclide, the calculated LLD(Lower Limit of Detection) is 5.0mBq/L which is lower than 40mBq/L of recommended LLD value by ISO(International Organization for Standardization).

  • PDF

A New Driving Method Generating Self-Erasing Discharge to Improve Luminous Efficiency in AC PDP (AC PDP에서 휘도효율을 향상시키기 위하여 자기소거 방전을 발생시키는 새로운 구동방법)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.168-172
    • /
    • 2014
  • A new sustain driving method is proposed to improve luminous efficiency by the generation of the self-erasing discharge during a sustain period in AC plasma display panel. As one subfield time in the conventional AC PDP is divided into the reset, address, and sustain period. Among them, as the square sustain waveform is alternately applied to the X and Y electrodes on the front plate during the sustain period, the plasma discharge for displaying the image is continuously produced. Meanwhile, in the conventional driving method, the address waveform applied to the A electrode on the rear plate is only driving during an address period and grounded during a sustain period. In this experiment, the negative pulse is applied to the A electrode at the latter part of the sustain pulse for improving the luminous efficiency producing the self-erasing discharge during the sustain period. The negative pulse on the A electrode can change from the space to the wall charge and induce the additional discharge by the accumulated wall charge when the voltages of three electrodes are grounded. As a result, the luminous efficiency will be measured with changes in the voltage level of the A electrode and the new driving method can be improved to the luminous efficiency about 32 % compared with the conventional driving method.

Liquid Crystal Driving of Transparent Electrode-Alignment Layer Multifunctional Thin Film by Nano-Wrinkle Imprinting of PEDOT:PSS/MWNT Nanocomposite (PEDOT:PSS/MWNT 나노복합체의 나노주름 임프린팅을 통한 투명전극-배향막 복합 기능 박막의 액정 구동)

  • Jong In Jang;Hae-Chang Jeong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.1
    • /
    • pp.8-17
    • /
    • 2023
  • In conventional liquid crystal display(LCD) manufacturing process, Indium Tin Oxide(ITO) as transparent electrode and rubbing process of polyimide as alignment layer are essential process to apply electric field and align liquid crystal molecules. However, there are some limits that deposition of ITO requires high vacuum state, and rubbing process might damage the device with tribolectric discharge. In this paper, we made nanocomposite with PEDOT:PSS and MWNT to replace ITO and constructed alignment layer by nano imprint lithography with nano wrinkle pattern, to replace rubbing process. These replacement made that only one PEDOT:PSS/MWNT film can function as two layers of ITO and polyimide alignment layer, which means simplification of process. Transferred nano wrinkle patterns functioned well as alignment layer, and we found out lowered threshold voltage and shortened response time as MWNT content increase, which is related to increment of electric conductivity of the film. Through this study, it may able to contribute to process simplification, reducing process cost, and suggesting a solution to disadvantage of rubbing process.

Interaction of Imipramine and $K^+$ Channel Blockers on Detrusor Muscle Strips Isolated from Canine Urinary Bladder (개의 적출방광 평활근에서 Imipramine과 $K^+$ 통로 봉쇄제와의 상호작용)

  • Huh, Joun-Young;Choi, Eun-Mee;Choi, Hyoung-Chul;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.2
    • /
    • pp.195-206
    • /
    • 1995
  • The study was undertaken to examine the possibility of the involvement of $K^+$ channels in the mechanism of relaxant-action of imipramine on the isolated canine detrusor muscle strips. Canine urinary bladder were isolated, and smooth muscle strips of 15 mm long and 2 mm wide from the mid-portion of anterior wall were made in the Tyrode solution of $0{\sim}4^{\circ}C$. The strips were prepared for isometric myography in Biancani's isolated muscle chamber containing 1 ml of Tyrode solution, which was maintained with pH 7.4 by aeration with $95%\;O_2/5%CO_2\;at\;37^{\circ}C$. RP 52891, a non-specific $K^+$ channel opener, concentration-dependently suppressed the spontaneous phasic contractions of the detrusor strips. Imipramine, a tricyclic antidepressant, also reduced the spontaneous contractions in a concentration-dependent manner. RP 52891 was more potent than imipramine(p<0.05), and Imipramine was more efficient than RP 52891(p<0.05).Procaine, a voltage-dependent $K^+$ channel blocker, glibenclamide, an ATP-dependent $K^+$ channel blocker, and apamin, a calcium-dependent $K^+$ channel blocker antagonized the relaxant effect of RP 52891, but not of imipramine. Imipramine reduced the electric field stimulation (EFS) -induced contractions concentration-dependently. None of the $K^+$ channel blockers employed for this study, procaine, glibenclamide or apamin antagonized the inhibitory action of imipramine on the EFS-induced contraction. These results suggest that in canine detrusor, the $K^+$ channels of the characteristics of voltage-dependent, ATP-dependent and/or calcium-dependent are exist, and the inhibitory action of imipramine on the contractility of the detrusor is independent from the $K^+$ channels.

  • PDF

Efficient Multicasting Mechanism for Mobile Computing Environment Machine learning Model to estimate Nitrogen Ion State using Traingng Data from Plasma Sheath Monitoring Sensor (Plasma Sheath Monitoring Sensor 데이터를 활용한 질소이온 상태예측 모형의 기계학습)

  • Jung, Hee-jin;Ryu, Jinseung;Jeong, Minjoong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.27-30
    • /
    • 2022
  • The plasma process, which has many advantages in terms of efficiency and environment compared to conventional process methods, is widely used in semiconductor manufacturing. Plasma Sheath is a dark region observed between the plasma bulk and the chamber wall surrounding it or the electrode. The Plasma Sheath Monitoring Sensor (PSMS) measures the difference in voltage between the plasma and the electrode and the RF power applied to the electrode in real time. The PSMS data, therefore, are expected to have a high correlation with the state of plasma in the plasma chamber. In this study, a model for predicting the state of nitrogen ions in the plasma chamber is training by a deep learning machine learning techniques using PSMS data. For the data used in the study, PSMS data measured in an experiment with different power and pressure settings were used as training data, and the ratio, flux, and density of nitrogen ions measured in plasma bulk and Si substrate were used as labels. The results of this study are expected to be the basis of artificial intelligence technology for the optimization of plasma processes and real-time precise control in the future.

  • PDF

A Study on the Bubble Deformation and Departure Under DC Electric Field (직류전기장에 의한 기포의 변형과 이탈에 관한 연구)

  • 권영철;김무환;강인석;김석준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

Reduction of Acoustic Resonance Phenomena in Pulse Start MetalHalide Lamp (MH200W) (고효율 펄스스타트 메탈핼라이드램프(MH200W)의 음향공명현상감소)

  • 김기정
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.8-14
    • /
    • 2001
  • MetalHalid lamps have good efficiency, good color rendition and good focusing capability. But the shortcoming of metalhalid lamps is blown as acoustic resonance phenomena in the arc tube. Such acoustic resonance produce annoying fluctuations in the intensity and distribution of the emitted light, they can raise the voltage to the point where the arc is extinguished and they can move the arc close enough to the wall to cause local overheating and tube cracking. The objective of this research is to reduce acoustic resonance in the arc tube of the Pulse Start MetaIHaide lamp(MH200[W]). To reduce the acoustic resonance phenomena the electronic ballast was designed for high frequency operation with the constant frequency sinusoidal wave of 89[kHz] in the 84.6[kHz]∼94.2[kHz] range. Experimental results show that the acoustic resonance phenomena are not in the arc tube of Pulse Start MetalHalide lamp (MH200[W]) .

  • PDF