• Title/Summary/Keyword: Wall Voltage

검색결과 206건 처리시간 0.024초

소형 변압기 안전성 실태 분석 및 고찰 (The Safety Survey Analysis and Consideration of Small Transformer)

  • 김성삼
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.

마이크로 채널 내 유도-전하 전기삼투에 의한 혼합 (Mixing in a Microchannel by using Induced-charge Electro-osmosis)

  • 전영훈;허영근;정원혁;수레수 알라파티;서용권
    • 한국가시화정보학회지
    • /
    • 제8권4호
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents an experimental study on the performance of a micro-mixer using AC electro-osmotic flow. The microchannel is made of PDMS for the side and top walls and glass patterned with ITO for the bottom wall. We first investigated the effect of the applied potential as well as the frequency on the slip velocity. We have found that the slip velocity is roughly proportional to the applied voltage in line with the Helmholtz-Smoluchowski equation and there is an optimum frequency at which the slip velocity becomes maximized. To find the optimum parameters for mixing device we tested our device for various design parameters. It turned out that the best mixing effect is obtained approximately when the electrode angle is $30^{\circ}$, electrode width $200\;{\mu}m$, and the frequency of power supply 700 Hz.

Hall 이력곡선 분해에 의한 Co/Pd 다층박막에서의 Antiferromagnetism 및 Exchange Anisotropy 분석 (A Study on the Antiferromagnetism and Exchange Anisotropy for Co/Pd Multilayered Thin Films by the Analysis of the Hall Effect)

  • 정진덕;이행기;김상록;이성래
    • 한국자기학회지
    • /
    • 제3권4호
    • /
    • pp.269-276
    • /
    • 1993
  • Co/Pd 다층박막에서 두 sublayer의 층수비($n_{Co}/n_{Pd}$ = 1/4, 2/4, 3/4, 5/4), 기판온도 ($실온,\;100,\;150,\;200\;^{\circ}C$)를 달리하는 시료를 열진공 증착방법으로 제작하고 이에 대한 Hall 이력곡선을 측정하였다. 이때 나타나는 다야한 형태의 이력곡선을 Co와 Pd sublayer의 자화에 의한 transverse Hall effect 항과 magnetoresistivity 항이 중첩된 것으로 보고 이를 최적 fiting 방법으로 분해하였다. 이 결과 시료 전체의 계면 영역에 걸쳐 강자성과 반강자성인 두 자화상태가 공존하며 이들의 exchange anisotropy의 크기와 반강자성 물질에 의한 강자성 물질의 자벽 고착 효과에 따라 uniaxal 또는 unidirectional easy axis 형의 Hall 이력곡선을 형성하는 것으로 나타났다.

  • PDF

Spectrum analysis of acoustic Barkhausen noise on neutron irradiated material

  • Sim Cheul-Muu;Park Seung-Sik;Park Duck-Gum;Lee Chang-Hee
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.231-234
    • /
    • 2000
  • In relation to a non-destructive evaluation of irradiation damage of micro-structure of interstitial, void and dislocation, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of reactor pressure vessel was irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$ $(E\ge1MeV)$ at $288^{\circ}C.$The saturation magnetization of neutron irradiated metal did not change. Neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by neutron irradiation. The spectrum of Barkhausen noise was analyzed with an applied frequency of 4Hz and 8Hz, and a sampling time of 50 $\mu$ sec and 20 $\mu$ sec. The harmonic frequency of Joule effect shows 4Hz, 8Hz, 12Hz and 16Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared for the irradiated specimen. Harmonic frequency of induced voltage of sinusoidal magnetic field And Spectrum of Barkhausen noise on material is determined.

  • PDF

Thrust Performances of a Very Low-Power Micro-Arcjet

  • Hotaka Ashiya;Tsuyoshi Noda;Hideyuki Horisawa;Kim, Itsuro ura
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.611-616
    • /
    • 2004
  • In this study, microfabrication of a micro-arcjet nozzle with Fifth-harmonic generation Nd:YAG pulses (wavelength 213 nm) and its thrust performance tests were conducted. A micro-arcjet nozzle was machined in a 1.2 mm thick quartz plate. Sizes of the nozzle were 0.44 mm in width of the nozzle exit and constrictor diameter of 0.1 mm. For an anode, a thin film of Au (~100 nm thick) was deposited by DC discharge PVD in vacuum on divergent part of the nozzle. As for a cathode, an Au film was also coated on inner wall surface. In operational tests, a stable discharge was observed for mass flow of 1.0mg/sec, discharge current of 6 ㎃, discharge voltage of 600 V, or 3.6 W input power (specific power of 3.6 MW/kg). In this case, plenum pressure of the discharge chamber was 80 ㎪. With 3.6 W input power, thrust obtained was 1.4 mN giving specific impulse of 138 sec with thrust efficiency of 24 %.

  • PDF

원통형 스퍼터링 장치로 제작한 Ti 및 Al 박막구조 (Structure of Ti and Al Films Prepared by Cylindrical Sputtering System)

  • 오창섭;한창석
    • 한국재료학회지
    • /
    • 제24권7호
    • /
    • pp.344-350
    • /
    • 2014
  • Metal films (i.e., Ti, Al and SUH310S) were prepared in a magnetron sputtering apparatus, and their cross-sectional structures were investigated using scanning electron microscopy. The apparatus used consisted of a cylindrical metal target which was electrically grounded, and two anode rings attached to the top and to the bottom of the target. A wire was placed along the center-line of the cylindrical target to provide a substrate. When the electrical potential of the substrate was varied, the metal-film formation rate depended on both the discharge voltage and the electrical potential of the substrate. As we made the magnetic field stronger, the plasma which appeared near the target collected on the plasma wall surface and thereby decreased the bias current. The bias current on the conducting wire was different from that for cation collection. The bias current decreased because the collection of cations decreased when we increased the magnetic-coil current. When the substrate was electrically isolated, the films deposited showed a slightly coarse columnar structure with thin voids between adjacent columns. In contrast, in the case of the grounded substrate, the deposited film did not show any clear columns but instead, showed a densely-packed granular structure. No peeling region was observed between the film and substrate, indicating good adhesion.

디지털 전기천공을 이용한 미세조류 내 단백질 전달 연구 (Delivery of Protein into Microalgae by the Digital Electroporation)

  • 임도진
    • Korean Chemical Engineering Research
    • /
    • 제56권1호
    • /
    • pp.79-84
    • /
    • 2018
  • 본 연구에서는 기 개발된 액적 접촉충전 기반의 디지털 전기천공 기술을 이용해 미세조류에 단백질을 전달하는 연구를 수행 하였다. Chlamydomonas reinhardtii 중 세포벽이 존재하는 야생종 cc-125에 적용한 결과, 살아 있는 세포의 핵 내부로 형광 단백질 GFP가 10% 이상의 비교적 높은 효율로 전달될 수 있음을 확인하였다. 또한 인가 전기장의 크기 변화에 따른 단백질 전달 효율을 살펴봄으로써 최적의 단백질 전달 효율을 위한 전기천공 전기장 조건을 도출하였다(960 V/cm). 전달 물질의 크기에 따른 영향 분석을 위해 추가로 수행한 핵산 염색 형광 염료 Yo-Pro-1의 전달 특성 분석 결과, 크기에 따른 차이가 존재함에도 최적의 전달 효율을 나타내는 인가 전기장의 세기 조건은 매우 유사한 경향을 보였다. 마지막으로 본 연구 결과의 의미 및 크리스퍼 유전자 가위 기술의 적용 등 향후 활용방안에 대해서 논의하였다.

시편의 준비 방법 및 접촉저항이 알루미늄 합금의 아노다이징 피막 형성에 미치는 영향 (Effects of Specimen Preparation Method and Contact Resistance on the Formation of Anodizing Films on Aluminum Alloys)

  • 문성모
    • 한국표면공학회지
    • /
    • 제53권1호
    • /
    • pp.29-35
    • /
    • 2020
  • In this study, five different specimen preparation methods were introduced and their advantages and disadvantages were presented. One of them, an epoxy mounting method has advantages of constant exposure area, ease of surface preparation without touching the specimen surface during polishing or cleaning, use of small amount of material and ease of specimen reuse by polishing or etching. However, in order to eliminate unexpected errors resulting from preferable reaction at the specimen/epoxy interface and contact resistance between the specimen and copper conducting line for electrical connection, it is recommended to cover the wall side of the specimen with porous anodic oxide films and to remain the contact resistance lower than 1 ohm. The increased contact resistance between the specimen and Cu conducting line appeared to result in increases of anodizing voltage and solution temperature during anodizing by which thickness and hardness of anodizing film on Al2024 alloy were drastically decreased and color of the films became more brightened.

Protective Effect of Right Ventricular Mitochondrial Damage by Cyclosporine A in Monocrotaline-induced Pulmonary Hypertension

  • Lee, Dong Seok;Jung, Yong Wook
    • Korean Circulation Journal
    • /
    • 제48권12호
    • /
    • pp.1135-1144
    • /
    • 2018
  • Background and Objectives: Mitochondria play a key role in the pathophysiology of heart failure and mitochondrial permeability transition pore (MPTP) play a critical role in cell death and a critical target for cardioprotection. The aim of this study was to evaluate the protective effects of cyclosporine A (CsA), one of MPTP blockers, and morphological changes of mitochondria and MPTP related proteins in monocrotaline (MCT) induced pulmonary arterial hypertension (PAH). Methods: Eight weeks old Sprague-Dawley rats were randomized to control, MCT (60 mg/kg) and MCT plus CsA (10 mg/kg/day) treatment groups. Four weeks later, right ventricular hypertrophy (RVH) and morphological changes of right ventricle (RV) were done. Western blot and reverse transcription polymerase chain reaction (RT-PCR) for MPTP related protein were performed. Results: In electron microscopy, CsA treatment prevented MCT-induced mitochondrial disruption of RV. RVH was significantly increased in MCT group compared to that of the controls but RVH was more increased with CsA treatment. Thickened medial wall thickness of pulmonary arteriole in PAH was not changed after CsA treatment. In western blot, caspase-3 was significantly increased in MCT group, and was attenuated in CsA treatment. There were no significant differences in voltage-dependent anion channel, adenine nucleotide translocator 1 and cyclophilin D expression in western blot and RT-PCR between the 3 groups. Conclusions: CsA reduces MCT induced RV mitochondrial damage. Although, MPTP blocking does not reverse pulmonary pathology, it may reduce RV dysfunction in PAH. The results suggest that it could serve as an adjunctive therapy to PAH treatment.

폴리 염화 비닐(PVC)의 저선량 융합 방사선에너지에 대한 차폐 효과 평가 (Evaluation of the Shielding Effect of Polyvinyl Chloride (PVC) on Low-dose Blending Radiation Energy)

  • 김선칠;조성현
    • 한국융합학회논문지
    • /
    • 제10권12호
    • /
    • pp.129-134
    • /
    • 2019
  • 의료기관에서 많이 사용되는 방사선 차폐 재료인 납을 대처할 수 있는 플라스틱 제품으로 PVC를 선택하였다. 방사선 차폐 의복 이외에 저선량 영역에서 의료기기 부품, 산업용 차폐 재료로 사용이 가능한지 평가하고자 한다. 상업용 PVC는 밀도가 3.68 g/㎠ 으로 재료의 유연성과 경제성 등 일정 방사선 영역에서는 충분한 차폐 효과를 긍정적으로 기대할 수 있으며, 다양한 형태로 변형이 가능하고, 경량의 차폐벽으로 사용할 수 있다. 의료기관에서 임상 검사 시 사용되는 의료방사선 영역 대에서 3mm PVC 5장을 두께로 조절하여 차폐 성능을 실험하였다. 의료방사선의 관전압 기준으로 실효에너지에 대한 차폐 성능을 평가하였다. PVC는 두께가 두꺼울수록 관전압과 실효에너지가 낮을수록 차폐효과는 크게 나타났으며, 차폐효과는 12mm 두께에 관전압 80kVp에서 70%의 차폐효과가 있었다. 따라서 PVC 재료의 차폐효과는 두께의 의존율이 높게 나타났다. 앞으로는 차폐 성능을 높이면서 얇고 가벼운 친환경 제품을 만들기 위한 지속적인 연구가 필요하다.