• Title/Summary/Keyword: WMA

Search Result 46, Processing Time 0.023 seconds

Design of a New Audio Watermarking System Based on Human Auditory System (청각시스템을 기반으로 한 새로운 오디오 워터마킹 시스템 설계)

  • Shin, Dong-Hwan;Shin Seung-Won;Kim, Jong-Weon;Choi, Jong-Uk;Kim, Duck-Young;Kim, Sung-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.7
    • /
    • pp.308-316
    • /
    • 2002
  • In this paper, we propose a robust digital copyright-protection technique based on the concept of human auditory system. First, we propose a watermarking technique that accepts the various attacks such as, time scaling, pitch shift, add noise and a lot of lossy compression such as MP3, AAC WMA. Second, we implement audio PD(portable device) for copyright protection using proposed method. The proposed watermarking technique is developed using digital filtering technique. Being designed according to critical band of HAS(human auditory system), the digital filers embed watermark without nearly affecting audio quality. Before processing of digital filtering, wavelet transform decomposes the input audio signal into several signals that are composed of specific frequencies. Then, we embed watermark in the decomposed signal (0kHz~11kHz) by designed band-stop digital filer. Watermarking detection algorithm is implemented on audio PD(portable device). Proposed watermarking technology embeds 2bits information per 15 seconds. If PD detects watermark '11', which means illegal song. PD displays "Illegal Song" message on LCD, skips the song and plays the next song, The implemented detection algorithm in PD requires 19 MHz computational power, 7.9kBytes ROM and 10kBytes RAM. The suggested technique satisfies SDMI(secure digital music initiative) requirements of platform3 based on ARM9E core.

A Plan for Building up the Rational Defense Acquisition System (합리적 국방획득체계 구축을 위한 방안)

  • Kim, Jong-Ha
    • Journal of the military operations research society of Korea
    • /
    • v.35 no.2
    • /
    • pp.15-31
    • /
    • 2009
  • This paper examines several inefficient problems generated from a management process of defense acquisition system, and suggests several alternatives to remedy the current acquisition-related problems. This might help MND to reform the current DAPA's acquisition system. The offered elements are to, first, redefine function of mid-term plan & budget allocation between MND and DAPA, second, devise economic acquisition management and force development to build integrated management system of requirement-acquisition-operation & maintenance, third, build Workforce Management Act(WMA) and Professional Education System(PES) for strengthening expertise and institutionalizing manpower rotation of requirements & acquisition-related fields, fourth, implement weapon systems' Total Life Cycle Systems Management(TLCSM) and improve developmental & operational test and evaluation. These are essential elements in minimizing confusion & conflict emanating from surrounding acquisition program among MND-DAPA-Each Services.

An Evaluation of Field Performance of Environmentally Friendly Asphalt Pavement (친환경 아스팔트 도로포장의 현장 공용성 분석)

  • Kim, Nakseok
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.22-29
    • /
    • 2013
  • Warm mix asphalt(WMA), which is produced at lower temperatures than hot mix asphalt, has advantages in reductions of fuel consumption and greenhouse-gas emission. In this study, field tests such as skid resistance, rutting(permanent deformation), and roughness were conducted for analysis of long-term field performance of modified warm mix asphalt pavement. Skid resistance after 20 months represents the result similar to initial performance results but rutting and roughness decreased somewhat depending on the period of performance. Measurement results of permanent deformation and roughness could be acceptable because measured pavement location is bus lane that a lot of buses pass and stop. There were no cracks after 11 months, but some minor cracks were observed after 20 months. These results were influenced by increased crack resistance due to fiber addition.

Evaluation of Fundamental Properties of Warm-mix Recycled Asphalt Concretes (준고온 재생 아스팔트 콘크리트의 기본특성 평가)

  • Kim, Nam-Ho;Kim, Jin-C.;Hong, Jun-P.;Kim, Kwang-W
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.111-120
    • /
    • 2010
  • This study evaluated strength properties of recycled asphalt concretes using warm-mix technology. Granite with maximum size of 13mm and penetration grade of 80-100 virgin binder were used for mixing in recycled mixtures. Mix design was performed using 20% and 30% RAP(coarse : fine= 6 : 4) contents. GPC, penetration, absolute viscosity and kinematic viscosity were measured for determining ratio of two warm-mix additives (Evotherm and Sasobit). Low-density polyethylene(LD) used as asphalt modifier for improving stiffness of recycled WMA mixtures in this study. Therefore, a total of 11 mixtures were prepared in this study; 8 warm-mix recycled mixtures(2 RAP contents${\times}$2 warm-mix additives${\times}$2 modifiers), 2 hot-mix recycled mixtures and 1 HMA virgin mixture(control). Deformation strength, indirect tensile strength, moisture sensitivity, permanent deformation by wheel tracking tests were measured out for evaluating fundamental properties of recycled asphalt concretes using warm-mix technology.

Integrated Eco-Engineering Design for Sustainable Management of Fecal Sludge and Domestic Wastewater

  • Koottatep, Thammarat;Polprasert, Chongrak;Laugesen, Carsten H.
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • Constructed wetlands and other aquatic systems have been successfully used for waste and wastewater treatment in either temperate or tropical regions. To treat waste or wastewater in a sustainable manner, the integrated eco-engineering designs are explained in this paper with 2 case studies: (i) a combination of vertical-flow constructed wetland (CW) with plant irrigation systemfor fecal sludge management and (ii) integrated CW units with landscaping at full-scale application for domestic wastewater treatment. The pilot-scale study of fecal sludge management employed 3 vertical-flow CW units, each with a dimension of $5{\times}5{\times}0.65m$ (width ${\times}$ length ${\times}$ media depth) and planted with cattails (Typha augustifolia). At the solid loading rate of 250 kg total solids (TS)/$m^2.yr$ and a 6-day percolate impoundment, the CW system could achieve chemical oxygen demand (COD), TS and total Kjeldahl nitrogen (TKN) removal efficiencies in the range of 80 - 96%. The accumulated sludge layers of about 80 - 90 cm was found at the CW bed surface after operating the CW units for 7 years, but no clogging problem has been observed. The CW percolate was applied to 16 irrigation Sunflower plant (Helianthus annuus) plots, each with a dimension of $4.5{\times}4.5m$ ($width{\times}length$). In the study, the CW percolate were fed to the treatment plots at the application rate of 7.5 mm/day but the percolate was mixed with tap water at different ratio of 20%, 80% and 100%. Based on a 1-year data of 3-crop plantation were experimented, the contents of Zn, Mn and Cu in soil of the experimental plots were found to increase with increasing in CW percolate ratios. The highest plant biomass yield and oil content of 1,000 kg/ha and 35%, respectively, were obtained from the plots fed with 20% or 50% of the CW percolate, whereas no accumulation of heavy metals in the plant tissues (i.e. leaves, stems and flowers) of the sunflower is found. In addition to the pilot-scale and field experiments, a case study of the integrated CW systems for wastewater treatment at Phi Phi Island (a Tsunami-hit area), Krabi province, Thailand is illustrated. The $5,200-m^2$ CW systems on Phi Phi Island are not only for treatment of $400m^3/day$ wastewater from hotels, households or other domestic activities, but also incorporating public consultation in the design processes, resulting in introducing the aesthetic landscaping as well as reusing of the treated effluent for irrigating green areas on the Island.

  • PDF

Regional frequency analysis using spatial data extension method : I. An empirical investigation of regional flood frequency analysis (공간확장자료를 이용한 지역빈도분석 : I. 지역홍수빈도분석의 실증적 검토)

  • Kim, Nam Won;Lee, Jeong Eun;Lee, Jeongwoo;Jung, Yong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.439-450
    • /
    • 2016
  • For the design of infrastructures controlling the flood events at ungauged basins, this study tries to find the regional flood frequencies using peak flow data generated by the spatial extension of flood records. The Chungju Dam watershed is selected to validate the possibility of regional flood frequency analysis using the spatially extended flood data. Firstly, based on the index flood method, the flood event data from the spatial extension method is evaluated for 22 mid/smaller sub-basins at the Chungju Dam watershed. The homogeneity of the Chungju dam watershed was assessed in terms of the different size of watershed conditions such as accumulated and individual sub-basins. Based on the result of homogeneity analysis, this watershed is heterogeneous with respect to individual sub-basins because of the heterogeneity of rainfall distribution. To decide the regional probability distribution, goodness-of fit measure and weighted moving averages method from flood frequency analysis were adopted. Finally, GEV distribution was selected as a representative distribution and regional quantile were estimated. This research is one step further method to estimate regional flood frequency for ungauged basins.