• Title/Summary/Keyword: W code

Search Result 741, Processing Time 0.029 seconds

Quantification of Realistic Discharge Coefficients for the Critical Flow Model of RELAP5/MOD3/KAERl (RELAP5 / MOD3/ KAERI의 임계유동모델을 위한 실제적 배출계수의 정량화)

  • Kwon, T.S.;Chung, B.D.;Lee, W.J.;Lee, N.H.;Huh, J.Y.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.701-709
    • /
    • 1995
  • The realistic discharge coefficient for the critical How model of RELAP5/AOD3/KAERI are determined for the subcooled and too-phase critical flow by assessments of nine MARVIKEN Critical flew Test(CFT). The selected test runs include a high initial subcooling and large nozzle aspect rat-io(L/D). The code assessment results show that RELAP5/MOD3/KAERI over-predicts the subcooled critical flow and under-predicts the two-phase critical flow. Using these result, the realistic discharge coefficients of critical flow models are quantified by an iterative method. The realistic discharge coefficients are determined to be 0.89 for the subcooled critical How and 1.07 for the two-phase critical flow, and the associated standard deviations are 0.0349 and 0.1189, respectively. The results obtained from this study can be applied to calculate the realistic system response of Large Break Loss of Coolant Accident and to evaluate the realistic Emergency Core Cooling System performance.

  • PDF

A report of sixteen unrecorded haloarchaea species in Korea, isolated from a solar saltern

  • Chi Young Hwang;Eui-Sang Cho;Dong-Hyun Jung;Ki-Eun Lee;In-Tae Cha;Won-Jae Chi;Myung-Ji Seo
    • Journal of Species Research
    • /
    • v.12 no.spc2
    • /
    • pp.45-53
    • /
    • 2023
  • In July 2018, solar saltern samples were collected from Siheung, Gyeonggi-do Province to obtain unrecorded haloarchaea in Korea. The samples were suspended in a 20% NaCl (w/v) solution, and serial dilution was performed in fresh DB Characterization media No. 2. The strains isolated in this study showed at least 98.7% sequence similarity or more compared to the previously reported. Finally, 16 haloarchaeal strains, which were not reported in Korea but validly published under the International Code of Nomenclature of Prokaryotes (ICNP), were obtained from a solar saltern in Siheung. These 16 isolates were allocated to the orders Halobacteriales and Haloferacales. The 10 Halobacteriales strains were classified into the family Halobacteriaceae and Haloarculaceae. Each family belonged to three genera, respectively. The other six Haloferacales belonged to the families Haloferacaceae and Halorubraceae. Each family belonged to genus genus, respectively. Collectively, the unrecorded haloarchaeal strains belonged to two orders, four families, and eight genera. During the research, the possibility of discovering previously unknown species in domestic solar saltern was established. Gram-staining, cell morphology, physiological and basic biochemical parameters, and phylogenetic analysis were all performed in this study and are described in detail for each strain.

Shear performance of reinforced concrete beams with rubber as form of fiber from waste tire

  • Ali Serdar Ecemis;Emrah Madenci;Memduh Karalar;Sabry Fayed;Sabry Fayed;Yasin Onuralp Ozkilic
    • Steel and Composite Structures
    • /
    • v.51 no.3
    • /
    • pp.337-349
    • /
    • 2024
  • The growing quantity of tires and building trash piling up in landfills poses a serious threat to the stability of the ecosystem. Researchers are exploring ways to reduce and use such byproducts of the construction industry in an effort to promote greener building practices. Thus, using recycled crumb rubber from scrap tires in concrete manufacturing is important for the industry's long-term viability. This study examines the proportion of waste rubber in fiber form, specifically at weight percentages of 5%, 10%, and 15%. Moreover, the study examines the shear behavior of reinforced concrete beams. A total of twelve RC beam specimens, each sized 100 mm by 150 mm by 1000 mm (w × d × L), were constructed and positioned to the test. Various mixtures were designed with different levels of scrap tire rubber content (0%, 5%, 10%, and 15%) and Stirrup Vol. Ratio (2.10, 2.80, and 3.53) in reinforced concrete beams. The findings indicate that the inclusion of scrap rubber in concrete leads to a decrease in both the mechanical characteristics and weight of the material. This is mostly attributed to the lower strength and stiffness of the rubberized concrete. Furthermore, estimations generated by a variety of design codes were examined alongside the obtained data. In order to make a comparison between the estimates provided by the different codes such as ACI 318-14, CEB-FIB and Iranian national building codes, a calculation was done to determine the ratio of the experimental shear strength to the anticipated shear strength for each code.

Thermal Property and Fire Resistance of Cellulose Insulation (섬유질 단열재의 열적 특성 및 내화성능)

  • Kwon, Young-Cheol;Seo, Seong Yeon;Kim, Sung Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2005
  • Cellulose insulation is primarily manufactured from recycled newsprint and treated with fire retardants for the fire resistance. Thanks to the fire retardants, it is not combustible and flammable. In addition to that, Its thermal resistance is much better than that of fiberglass or rock wool. It is made from waste paper and easily decayed when it is demolished, and it has small embodied energy. So it is very environment-friendly building material. For broader use of cellulose insulation in buildings in Korea, it is necessary to test its physical performance to compare the results with the requirements on the Korean Building Code. To this end, apparent thermal conductivity (ka) measurements of Korean-made loose-fill cellulose insulations were recently completed using equipment that was built and operated in accordance with ASTM C 518 and the fire resistance was tested in accordance with ASTM C 1485. Korean loose-fill cellulose has thermal conductivity about 5% greater than the corresponding U.S. product at the same density. This is likely due to differences in the recycled material being used. Both spray-applied and loose-fill cellulose insulation lose about 1.5% of their thermal resistivity for $5.5^{\circ}C$ increase in temperature. The fire resistance of cellulose insulation is increased in linear proportion to the increase of the rate of fire retardant. Thanks to the high fire resistance, cellulose insulation can be used as a substitution of Styrofoam or Urethane foam which is combustible. The thermal conductivity of cellulose insulation was $0.037-0.043W/m{\cdot}K$ at the mean specimen temperature from $4-43^{\circ}C$. It corresponds to the thermal resistance of "Na Grade" according to the Korean Building Code. The effect of chemical content on thermal conductivity was negligible for all but the chemical-free specimen which had the highest value for the thermal conductivity over the temperature range tested. The thermal resistance of cellulose insulation is better than that of fiberglass or rock wool, and its fire resistance is higher than that of Styrofoam or Urethane foam. Therefore it can be substituted for those above considering its physical performance. Cellulose insulation is no more expensive than Styrofoam or rock wool, so it is recommended to use it more widely in Korea.

Monitoring and Risk Assessment of Lead and Cadmium in Various Agricultural Products Collected from the Korean Market

  • Chang, Eun Jung;Park, Sung Hee;Lee, Kyung Jin;Choe, Jee su;Kim, Mee hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.4
    • /
    • pp.240-247
    • /
    • 2018
  • This study was carried out to determine the levels of lead and cadmium as found in nine agricultural products (n = 578) sold in Korea, and to estimate the risk to human health that is summarily associated with their intake. The concentrations of Pb and Cd were measured using an ICP-MS after microwave digestion in this study. The average contents of Pb and Cd were measured as 0.014 and 0.017 mg/kg for barley, 0.006 and 0.005 mg/kg for mung bean, 0.008 and 0.007 mg/kg for kidney bean, 0.010 and 0.004 mg/kg for green bean, 0.008 and 0.001 mg/kg for pineapple, 0.016 and 0.002 mg/kg for apricot, 0.015 and 0.002 mg/kg for Japanese apricot, 0.021 and 0.002 mg/kg for plum and 0.019 and 0.003 mg/kg for jujube, respectively. The levels of Pb and Cd in the study samples were less than the maximum residual levels established by the European Union (EU), CODEX, and the Korea Food Code. As we have seen, the daily dietary exposures of Pb and Cd from these agricultural products for the general population were noted as 0.067% of PTWI ($25{\mu}g/kg$ b.w./week) and 0.28% of PTMI ($25{\mu}g/kg$ b.w./month), respectively. In line with the study conclusions, these results suggest that the current dietary intakes of Pb and Cd from these agricultural products in Korea have no appreciable risk effects on health for humans as noted in this experiment.

The Development of Air-kerma Strength Calculation Algorithm in Terms of the Absorbed Dose to Water for HDR Ir-192 Source (기준점에서의 물 흡수선량을 이용한 Ir-192 선원의 공기커마 세기 계산을 위한 알고리즘 개발)

  • Huh, Hyun-Do;Kim, Woo-Chul;Loh, John-Jk;Lee, Suk;Lee, Sang-Hoon;Cho, Sam-Ju;Shin, Dong-Oh;Choi, Jin-Ho;Kwon, Soo-Il;Kim, Seong-Hoon
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.232-237
    • /
    • 2006
  • The aim of this study was to develop the calculation algorithm of source strength of Ir-192 source In terms of the absorbed dose to water instead of an apparent activity (Ci). For this work the Multi Purpose Brachytherapy Phantom(MPBP) was developed, which was designed to locate the source and the chamber precisely at a specific position Inside the water phantom. The reference point of measurement was set at the 5 cm distance along the transverse axis of the source. For a brachytherapy source calibration, the absorbed dose to water calibration factor ($N_{D.W.Q}$) of an lonization chamber were determined and then apply standard protocols of absorbed dose to water. The calibration factor ($N_{D.W.Q}$) of the ion chamber (TM30013, PTW, Germany) was determined using the EGSnrcCPP Monte Carlo Code. The calculated calibration factor ($N_{D.W.Q}$) was 5.28 cGy/nC. The calculated factor was then used to determine the absorbed dose to water from which the air kerma strength for an Ir-192 source can be easily derived at the reference point (5 cm). The calculated air kerma strength showed discrepancies of -0.6% to +1.8% relative to the air kerma strength provided by the vendor, In this work we demonstrated that the air kerma strength ($S_k$) could be determined from the absorbed dose to water calibration factor for Ir-192 source. In audition, this source calibration method could be applied directly to the dose Calculation formalism of AAPM report TG-43.

  • PDF

INTERACTION OF SUPERNOVA REMNANTS WITH STELLAR-WIND BUBBLES (초신성 잔해와 항성풍 공동간의 상호 작용)

  • Lee, Jae-Kwan;Koo, Bon-Chul
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.111-143
    • /
    • 1997
  • We have developed a spherical FCT code in order to simulate the interaction of supernova remnants with stellar wind bubbles. We assume that the density profile of the supernova ejecta follows the Chevalier mode1(1982) where the outer portion has a power-law density distribution($\rho{\propto}\gamma^{-n}$) and the SN ejecta has a kinetic energy of $10^{51}$ ergs. The structure of wind bubble has been calculated with the stellar mass loss rate $\dot{M}=5\times10^{-6}M_{\odot}/yr$ and the wind velocity $\upsilon=2\times10^3$ km/s We have simulated seven models with different initial conditions In the first two models we computed the evolution of SNRs with n=7 and n=14 in the uniform medium The numerical results agree with the Chevalier's similarity solution at early times. When all of the power-law portion of the ejecta is swept up by the reverse shock, the evolution slowly converges to the Sedov-Taylor stage. There is not much difference between the two cases with different n's The other five models simulate SNRs produced inside wind bubbles. In model III, we consider the SN ejecta of 1.4 $M_{\odot}$ and the radius of bubble ~2.76 pc so that ratio of the mass $\alpha(=M_{W.S}/M_{ej}$ is 2. We follow the complex hydrodynamic flows produced by the interaction of SN shocks with stellar shocks and with the contact discontinuities, In the model III, the time scale for the SN shock to cross the wind shell $\tau_{cross}$ is similar to the time scale for the reverse shock to sweep the power-law density profile $\tau_{bend}$. Hence the SN shock crosses the wind shell. At late times SN shock produces another shell in the ambient medium so that we have a SNR with double shell structure. From the numerical results of the remaining models, we have found that when $\tau_{cross}/\tau_{bend}\leq2$, or equivalently when $\alpha\leq50$, the SNRs produced inside wind bubbles have double shell structure. Otherwise, either the SN shock does not cross the wind shell or even if it crosses at one time, the reverse shock reflected at the center accelerates the wind shell to merge into the SN shock Our results confirm the conclusion of Tenorio-Tagle et a1(1990).

  • PDF

Improvement of Residual Delay Compensation Algorithm of KJJVC (한일상관기의 잔차 지연 보정 알고리즘의 개선)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Oh, Chung-Sik;Jung, Jin-Seung;Chung, Dong-Kyu;Oyama, Tomoaki;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kawakami, Kazuyuki;Ozeki, Kensuke;Onuki, Hirohumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.2
    • /
    • pp.136-146
    • /
    • 2013
  • In this paper, the residual delay compensation algorithm is proposed for FX-type KJJVC. In case of initial version as that design algorithm of KJJVC, the integer calculation and the cos/sin table for the phase compensation coefficient were introduced in order to speed up of calculation. The mismatch between data timing and residual delay phase and also between bit-jump and residual delay phase were found and fixed. In final design of KJJVC residual delay compensation algorithm, the initialization problem on the rotation memory of residual delay compensation was found when the residual delay compensated value was applied to FFT-segment, and this problem is also fixed by modifying the FPGA code. Using the proposed residual delay compensation algorithm, the band shape of cross power spectrum becomes flat, which means there is no significant loss over the whole bandwidth. To verify the effectiveness of proposed residual delay compensation algorithm, we conducted the correlation experiments for real observation data using the simulator and KJJVC. We confirmed that the designed residual delay compensation algorithm is well applied in KJJVC, and the signal to noise ratio increases by about 8%.

A Sensitivity Analysis of Design Parameters of an Underground Radioactive Waste Repository Using a Backpropagation Neural Network (Backpropagation 인공신경망을 이용한 지하 방사성폐기물 처분장 설계 인자의 민감도 분석)

  • Kwon, S.;Cho, W.J.
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.203-212
    • /
    • 2009
  • The prediction of near field behavior around an underground high-level radioactive waste repository is important for the repository design as well as the safety assessment. In this study, a sensitivity analysis for seven parameters consisted of design parameters and material properties was carried out using a three-dimensional finite difference code. From the sensitivity analysis, it was found that the effects of borehole spacing, tunnel spacing, cooling time and rock thermal conductivity were more significant than the other parameters. For getting a statistical distribution of buffer and rock temperatures around the repository, an artificial neural network, backpropagation, was applied. The reliability of the trained neural network was tested with the cases with randomly chosen input parameters. When the parameter variation is within ${\pm}10%$, the prediction from the network was found to be reliable with about a 1% error. It was possible to calculate the temperature distribution for many cases quickly with the trained neural network. The buffer and rock temperatures showed a normal distribution with means of $98^{\circ}C$ and $83.9^{\circ}C$ standard deviations of $3.82^{\circ}C$ and $3.67^{\circ}C$, respectively. Using the neural network, it was also possible to estimate the required change in design parameters for reducing the buffer and rock temperatures for $1^{\circ}C$.

Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent (연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석)

  • Park, Min jung;Choi, Duck kyu;Son, Jin kwan;Yoon, Sung-Wook;Kim, Hee tae;Lee, Seung-Kee;Kang, Dong hyeon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • The objectives of this study were to investigate the standard and roof vent type of multi-span greenhouse and to analyze the characteristics of natural ventilation of multi-span greenhouse with different roof vent using computational fluid dynamics (CFD) code. The vent area proportion of surveyed farms averaged 10%, it was analyzed that the vent design for natural ventilation is insufficient. The results of natural ventilation efficiency of multi-span greenhouse according to roof vent type showed that the temperature of the position in which the crops grew was the lowest in the conical roof vent type and the highest in the half conical roof vent type. For the natural ventilation effect, the conical roof vent type was the best one, but the structural stability should be evaluated in light of wind load.