• Title/Summary/Keyword: W(110)

Search Result 646, Processing Time 0.033 seconds

Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well (지하수정호 결합 복합지열시스템의 시범운영 효과분석)

  • Song, Jae-Yong;Kim, Ki-Joon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.28 no.3
    • /
    • pp.475-488
    • /
    • 2018
  • This study evaluates geothermal system efficiency in terms of input power and heat exchange volume on the heat-source and load sides, by applying a combined open-closed type loop system comprising a geothermal system and a groundwater well to a cultivation site. In addition, this study analyzes the effects of heating and cooling for a complex geothermal system, by evaluating the temperatures of an external site and a cultivation site during operation. During cooling operations the heat exchange volume on the heat source side, average 90.0kW/h for an open type system with an input of 235L/minute groundwater, and 40.1kW/h for a closed type system with an input of 85L/minute circulating water, for a total average heat exchange volume of 130.1kW/h. The actual heat exchange volume delivered on the load side averages 110.4kW/h. The average EER by analysis of the geothermal system's cooling efficiency is 5.63. During heating operation analysis, the heat exchange volume on the heat source side, average 60.4kW/h in an open type system with an input of 266L/minute groundwater, and 22.4kW/h in closed type system with an input of 86L/minute circulating water, for a total average heat exchange volume of 82.9kW/h. The actual heat exchange volume delivered on the load side averages 112.0kW/h in our analysis. The average COP determined by analysis of the geothermal system's heating efficiency is 3.92. Aa a result of the tradeoff between the outside temperature and the inside temperature of the production facility and comparing the facility design with a combined well and open-closed loops geothermal(CWG) system, we determine that the 30RT-volume CWG system temperature are lower by $3.4^{\circ}C$, $6.8^{\circ}C$, $10.1^{\circ}C$ and $13.4^{\circ}C$ for ouside temperature is of $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$, respectively. Based on these results, a summer cooling effect of about $10^{\circ}C$ is expected relative to a facility without a CWG system as the outside temperature is generally ${\geq}30^{\circ}C$. Our results suggest that a complex geothermal system provides improvement under a variety of conditions even when heating conditions in winter are considered. Thus It is expected that the heating-cooling tradeoffs of complex geothermal system are improved by using water screen.

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

Characteristics of Joint Systems and Their Relationship with Groundwater System in the Nakdong River Mid-basin (낙동강 중류 유역의 단열계 특성 및 지하수계와의 관련성)

  • Kim, Deuk-Ho;Lee, Jong-Hyun;Park, Kyu-Tae;Kim, Seong-Chang;Choi, Yu-Mi;Seo, Yu-Ri;Noh, Gyung-Myung;Hamm, Se-Yeong
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.483-492
    • /
    • 2008
  • The characteristics of joint system (joint orientation and density) were studied for Cretaceous sedimentary rocks in the Nakdong River mid-basin (Haman-Gun, Changnyeong-Gun, and Uiryeong-Gun areas), and were related with faults, river system, and groundwater usage in the study area. The joint system was classified into JI ($N90^{\circ}-110^{\circ}E$), J2 ($N0^{\circ}-35^{\circ}E$), and J3 ($(N0^{\circ}-35^{\circ}W$), and was dominant along N-S and E-W directions. The N-S trending joint system is dominant in Haman Formation in the eastern and western parts of the study area, while the E-W trending joint system is prevalent in Chilgok Formation in the central part. The joint system may be associated with the faults located in the eastern and western parts in the study area which are elongated to NNE-SSW direction. Additionally, the joint density is higher along the Nakdong River, indicating close relationship between E-W trending joints and the river. Daily groundwater discharge versus joint density shows weak positive relationship, and specific capacity versus joint density appears negatively related. This indicates that groundwater occurrence does not greatly rely on joint density.

Polymer Planar-Lightwave-Circuit-Type Variable Optical Attenuator Fabricated by Hot Embossing Process

  • Kim, Jin-Tae;Choi, Choon-Gi;Sung, Hee-Kyung
    • ETRI Journal
    • /
    • v.27 no.1
    • /
    • pp.122-125
    • /
    • 2005
  • A polymer-based planar-lightwave-circuit-type variable optical attenuator (VOA) was fabricated using a hot embossing process. With an optimized one-step embossing process, forty micro-channels for the guidance of light were defined on a polymer thin film with an accuracy of ${\pm}0.5{\mu}m$. The fabricated polymeric thermo-optic VOA shows 30 dB attenuation with 110 mW electrical input power at $1.55{\mu}m$. The rise and fall times are less than 5 ms.

  • PDF

Design of PLL for Low Voltage and High Speed Operation (저전압, 고속동작을 하는 위상 동기 루프(PLL)의 설계)

  • 조용덕;윤영승유상대
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1097-1100
    • /
    • 1998
  • In this paper, the PLL(Phase-Locked Loops) for low voltage and high speed operation is described. In other to obtaining above objects, new CMOS circuit technologies have been used in the each block circuit of PLL. It operates with a lock range from 110 up to 700 MHz and has a peak to peak jitter of 50 ps at operating frequency of 250 MHz. It was fabricated in a $0.6\mu\textrm{m}$ CMOS technology and dissipated 45 mW from a single 3.3V.

  • PDF

Efficiency and Minimaxity of Bayes Sequential Procedures in Simple versus Simple Hypothesis Testing for General Nonregular Models

  • Hyun Sook Oh;Anirban DasGupta
    • Journal of the Korean Statistical Society
    • /
    • v.25 no.1
    • /
    • pp.95-110
    • /
    • 1996
  • We consider the question of efficiency of the Bayes sequential procedure with respect to the optimal fixed sample size Bayes procedure in a simple vs. simple testing problem for data coming from a general nonregular density b(.theta.)h(x)l(x < .theta.). Efficiency is defined in two different ways in these caiculations. Also, the minimax sequential risk (and minimax sequential stratage) is studied as a function of the cost of sampling.

  • PDF

Shock Response Analysis of Guard Robot Considering the Elastic Effect (탄성 효과를 고려한 감시 로봇 모델의 충격 응답 해석)

  • Kim, Jung-Chan;Jeong, W.B.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.107-110
    • /
    • 2006
  • In this paper, shock response analysis considering the elastic effects of guard robot is performed using computer simulations when a machine gun of guard robot fires a shot continuously. The bodies of guard robot are modelled in flexible multi-body. The results of its analysis is compared with results of rigid bodies. The tools of computer simulation is used in Multi-body dynamics program.

  • PDF

Development of Electronic Ballast for 110W T5 Fluorescence Lamp (330W용 UV 램프용 전자식 안정기 개발)

  • Yi, Chin-Woo;Choi, Hyun-Bae;Park, Jae-Kweon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.185-186
    • /
    • 2004
  • UV 램프 시스템은 산업, 환경분야에서 폭넓게 사용되고 있으며, 램프의 용량이 커지는 추세를 보이고 있다. 이에 본 연구에서는 출력이 보다 안정화되고, 대용량에 적합한 고효율 UV램프 구동시스템을 개발하였다.

  • PDF

A Review of Teleommuniations Broadcasting Convergence Trends and Services: Focusing on Digital Multimedia Broadcasting Satellite Services in Korea (통신.방송 융합서비스 주요 동향 및 이슈: 국내 위성 DMB 서비스 도입 현황을 중심으로)

  • Song, Y.W.;Chung, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.19 no.2 s.86
    • /
    • pp.101-110
    • /
    • 2004
  • 본 연구에서는 통신. 방송 융합의 개념과 통신. 방송 융합 서비스의 현황을 알아보고 통신. 방송 융합 서비스관련 국내외의 분류 기준을 살펴보고자 한다. 또한 대표적인 통신. 방송 융합형 서비스인 위성 DMB 서비스를 실제로 연구에 적용하여, 국내 위성 DMB 서비스 관련 정책환경 분석과 더불어 위성 DMB 서비스와 유사서비스와의 비교를 통해 통신. 방송 융합서비스가 보유하고 있는 차별적 성격을 도출하는 한편, 그 시사점을 제시하고자 한다.