• Title/Summary/Keyword: Volume difference

Search Result 2,541, Processing Time 0.035 seconds

Measurement of Maxillary Sinus Volume Using Computed Tomography (전산화단층사진술을 이용한 상악동 체적의 측정)

  • Park Chang-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.63-70
    • /
    • 2000
  • Purpose: To propose a standard value for the maxillary sinus volume of a normal Korean adult by measuring the width and height of the sinus and analyzing their correlation and the difference of the sinus size respectively between sexes, and on the right and left sides. Materials and Methods: Fifty-two (95 maxillary sinuses) out of 20 years or over aged patients who had taken CT in the Department of Dental Radiology, Yonsei University, Dental Hospital, between February 1997 and July 1999 who were no specific symptom, prominent bony septa, pathosis, clinical asymmetry and history of surgery in the maxillary sinus were retrospectively analyzed. Results: The mean transverse width, antero-posterior width, height and volume of the normal Korean adult's maxillary sinuses were 28.33 mm, 39.69 mm, 46.60 mm and 21.90 cm³, respectively. There was a significant sex difference in the sinus volume (p>0.05). In the mean antero-posterior width, height and volume of the sinus, no significant difference was observed between both sides. All four measurements showed a significant correlation between both sides (p>0.0001). The widths and height of the sinus all showed a significant correlation with the sinus volume (p>0.0001). Conclusion : In the Korean normal adult's maxillary sinus, males tended to be larger than females. Except for the transverse width, all of the measurements showed no significant difference between the right and left side, but significant correlations in the four measurements between both sides were observed. Thus, the overgrowth or undergrowth in the unilateral maxillary sinus may suggest a certain pathosis or developmental abnormalities in the maxillary sinus.

  • PDF

Comparing Difference of Volume of Psychiatric Treatments between the Patient with Health Insurance and Those with Medical Assistance - For Inpatients of Korean Psychiatric Hospitals - (건강보험과 의료급여 환자간의 정신요법 진료량 차이 비교 - 정신병원 입원환자를 대상으로 -)

  • Lee, Dae-Hee;Park, Eun-Cheol;Nam, Chung-Mo;Lee, Sang-Gyu;Lee, Dong-Han;Yu, Seung-Hum
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.1
    • /
    • pp.33-38
    • /
    • 2003
  • Objectives : To assess the difference in the volume of psychiatric treatments provided to health insurance inpatients, compared with those on medical assistance(the medical aid program) Korean psychiatric hospitals, and to determine factors which affect the volume of the services. Methods : 21 psychiatrists, from 3 Korean psychiatric hospitals recorded the frequencies psychiatric treatments provided to inpatients in one week (February 18-24, 2002). The records of 329 patients were analyzed through t-tests, and random effectmixed model analyses to define the difference between the two groups, and to find other factors affecting the volume of service. Results : A significant difference in the volume of psychiatric treatments provided was observed between the health insurance and medical assistance groups. The variation in the volume of service between hospitals was prominent, and other factors (gender, agegroup, length of stay and mental disorder)were also found to be significant. The patients on medical assistance received only 70% of the psychiatric treatments of those on health insurance. Conclusions : More effort is required to improve the methods of payment to increase the level of fee scheduling for medical assistance. Further studies on the mechanisms causing these differences in the volume of service are required.

Numerical Simulation of Multiphase Flows with Material Interface due to Density Difference by Interface Capturing Method (경계면 포착법에 의한 밀도차이에 따른 물질경계면을 갖는 다상유동 수치해석)

  • Myon, Hyon-Kook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.443-453
    • /
    • 2009
  • The Rayleigh-Taylor instability, the bubble rising in both partially and fully filled containers and the droplet splash are simulated by an in-house solution code(PowerCFD), which are typical benchmark problems among multiphase flows with material interface due to density difference. The present method(code) employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with interface capturing method(CICSAM) in a volume of fluid(VOF) scheme for phase interface capturing. The present results are compared with other numerical solutions found in the literature. It is found that the present method simulates efficiently and accurately complex free surface flows such as multiphase flows with material interface due to both density difference and instability.

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.

Numerical Simulation of Two-Dimensional Multiphase Flows due to Density Difference by Interface Capturing Method (경계면포착법에 의한 밀도차에 따른 다상유동 수치해석)

  • Myong, Hyon-Kook
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.572-575
    • /
    • 2008
  • Two-dimensional multiphase flows due to density difference such as the Rayleigh-Taylor instability problem and the droplet splash are simulated by an in-house solution code(PowerCFD). This code employs an unstructured cell-centered method based on a conservative pressure-based finite-volume method with interface capturing method in a volume of fluid(VOF) scheme for phase interface capturing. The present results are compared with other numerical solutions found in the literature. It is found that the present code simulates complex free surface flows such as multiphase flows due to density difference efficiently and accurately.

  • PDF

Interchange 주변토양의 중금속 농도 분포

  • 이주광;강혜진;강희만;이찬영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.271-274
    • /
    • 2002
  • Heavy metal concentrations of roadside soils around interchanges were found to decrease as Zn)Cu>Pb and be lower than the legal guideline levels. The concentrations of Cu, Pb and Zn in roadside soils around Kyeong-bu highway interchanges were 1.3 to 1.5 times higher those around Yeong-dong highway interchanges. Difference of heavy metal concentrations in soils seems to be caused by difference of traffic volume between Kyeong-bu and Yeong-dong highway interchanges. This means that contamination of interchange roadside soils mainly depends on traffic volume.

  • PDF

A comparison of preplan MRI and preplan CT-based prostate volume with intraoperative ultrasound-based prostate volume in real-time permanent brachytherapy

  • Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Chang, Sei-Kyung;Ko, Seung-Young;Kim, Sung-Jun;Park, Dong-Soo;Shin, Hyun-Soo
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • Purpose: The present study compared the difference between intraoperative transrectal ultrasound (iTRUS)-based prostate volume and preplan computed tomography (CT), preplan magnetic resonance imaging (MRI)-based prostate volume to estimate the number of seeds needed for appropriate dose coverage in permanent brachytherapy for prostate cancer. Materials and Methods: Between March 2007 and March 2011, among 112 patients who underwent permanent brachytherapy with $^{125}I$, 60 image scans of 56 patients who underwent preplan CT (pCT) or preplan MRI (pMRI) within 2 months before brachytherapy were retrospectively reviewed. Twenty-four cases among 30 cases with pCT and 26 cases among 30 cases with pMRI received neoadjuvant hormone therapy (NHT). In 34 cases, NHT started after acquisition of preplan image. The median duration of NHT after preplan image acquisition was 17 and 21 days for cases with pCT and pMRI, respectively. The prostate volume calculated by different modalities was compared. And retrospective planning with iTRUS image was performed to estimate the number of $^{125}I$ seed required to obtain recommended dose distribution according to prostate volume. Results: The mean difference in prostate volume was 9.05 mL between the pCT and iTRUS and 6.84 mL between the pMRI and iTRUS. The prostate volume was roughly overestimated by 1.36 times with pCT and by 1.33 times with pMRI. For 34 cases which received NHT after image acquisition, the prostate volume was roughly overestimated by 1.45 times with pCT and by 1.37 times with pMRI. A statistically significant difference was found between preplan image-based volume and iTRUS-based volume (p<0.001). The median number of wasted seeds is approximately 13, when the pCT or pMRI volume was accepted without modification to assess the required number of seeds for brachytherapy. Conclusion: pCT-based volume and pMRI-based volume tended to overestimate prostate volume in comparison to iTRUS-based volume. To reduce wasted seeds and cost of the brachytherapy, we should take the volume discrepancy into account when we estimate the number of $^{125}I$ seeds for permanent brachytherapy.

Hippocampal Volume and Memory Function in Patients with Posttraumatic Stress Disorder (외상후 스트레스 장애 환자에서 해마용적과 기억기능)

  • Chung, Moon-Yong;Chung, Hwa-Yong;Ryu, Hyun;Chung, Hae-Gyung;Choi, Jin-Hee
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.131-139
    • /
    • 2001
  • This study was conducted to evaluate the effect of PTSD on memory function and hippocampal volume, and to identify major variables correlated to hippocampal volume and memory function. Thirty four Vietnam veterans were collected for this study, among whom eighteen were PTSD patients and sixteen were combat control subjects. The author used Impact of Event Scale(IES), Combat Exposure Scale(CES), Hamilton Depression Rating Scale(HDRS) and Beck Depression Inventory (BDI). Korea Memory Assessment Scale(K-MAS) was assessed for memory function. Magnetic resonance imaging(MRI) was used to measure hippocampal volume. There were significant differences between PTSD and Non-PTSD veterans in IES, HDRS and BDI. Significant difference was found in verbal memory and total memory of K-MAS between PTSD and Non-PTSD veterans. There was significant difference in hippocampal volume between PTSD and Non-PTSD veterans. Short term memory, verbal memory and total memory were positively correlated to hippocampal volume. Hippocampal volume was negatively correlated to IES, HDRS, and BDI. These results suggest that PTSD severity be associated with hippocampal atrophy and memory dysfunction. Reduced or smaller hippocampal volume may be preexisting risk factor for stress exposure or the development of PTSD on combat exposure.

  • PDF

Improvement of Representative Value through Comparison of the Reliability of point detector : focusing on traffic volume (지점검지기 신뢰도 비교를 통한 대표치 생성 개선방안 : 구간 교통량을 중심으로)

  • Choi, Yoon-Hyuk;Lee, Yoon-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.5
    • /
    • pp.22-35
    • /
    • 2013
  • With the increase in image detectors, concerns about the reliability of traffic information are increasing. In this paper, we propose a method to generate reliable traffic volume using analysis of the point detector data as a representative value. Therefore, targeting expressway, we analyzed the difference in traffic volume collected by loop and image detector, and verified statistically using t-test, and finally analyzed the error rate compare to the real traffic volume. Analysis revealed that there was a statistically difference the traffic date collected by the loop detector and the image detector, in the same period, the same time, respectively. In addition, the difference between the actual traffic volume and traffic that have been collected in a loop detector was the lowest Therefore, creating a traffic volume of representative value, we proposed a method to use loop detector than the average traffic volume collected by each detector. It shows that it is more important to use one high-quality data rather than various low-quality data to produce a representative value.

Direct Simulations of Aerodynamic Sounds by the Finite Difference and Finite Volume Lattice Boltzmann Methods

  • Tsutahara, Michihisa;Tamura, Akinori;Motizuki, Kazumasa;Kondo, Takamasa
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.22-25
    • /
    • 2006
  • Direct simulations of aerodynamic sound, especially sound emitted by rapidly rotating elliptic cylinder by the finite difference lattice Boltzmann method (FDLBM). Effect of pile-fabrics for noise reduction is also studied by the finite volume LBM (FVLBM) using an unstructured grid. Second order time integration and third order upwind scheme are shown to be enough for these simulations. Sound sources are detected to be doublets for both cases. For the elliptic cylinder, the doublet is generated in the interaction between the vortex and the edge. For the circular cylinders, they are generated synchronizing with the Karman vortex street, and it is also shown that the pile-fabrics covering the surface of the cylinder reduces the strength of the source.

  • PDF