• 제목/요약/키워드: Voltage-mode control

검색결과 888건 처리시간 0.024초

R-L부하를 가진 구형파 VSI의 전압크기 제어 (Voltage Amplitude Control of Square-Wave VSIs with an R-L Load)

  • 김경원;홍순찬;유종걸;김상균;박채운
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.479-482
    • /
    • 2001
  • This paper proposes a modified $\alpha$ conduction mode for controlling the output voltage magnitude of three-phase square-wave VSIs with an R-L load. From the viewpoint of both power capacity and switching losses, three-phase square-wave inverters are now used in most high power systems. When the square-wave VSI is driven with $\alpha$ conduction mode to control the magnitude of output voltages, interval over than half period is operated with $180^{\circ}$ conduction mode and the other interval with $120^{\circ}$ conduction mode. In $120^{\circ}$ conduction mode operation, two output terminals are connected to DC supply and the third one remains open. The potential of this open terminal will depend on the load characteristics and is unpredictable except the case of pure resistive loads. To cope this problem, we propose the modified α conduction mode.

  • PDF

멀티비트 플라잉 커패시터의 전압제어를 이용한 3-레벨 벅 변환기 (Three Level Buck Converter Utilizing Multi-bit Flying Capacitor Voltage Control)

  • 소진우;윤광섭
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1006-1011
    • /
    • 2018
  • 본 논문은 멀티비트 플라잉 커패시터의 전압제어를 이용한 3-레벨 벅 변환기를 제안한다. 기존의 3-레벨 벅 변환기는 플라잉 커패시터 전압을 제어하지 못하여 동작이 불안정하거나 플라잉 커패시터 전압을 제어하는 회로가 PWM방식에 적용되지 못하는 문제가 있었다. 또한 부하전류에 증가할 때 인덕터 전압에 오차가 발생하였다. 본 논문에서 제안하는 구조는 입력이 4개인 차동증폭기와 공통모드 피드백 회로를 이용하여 PWM모드에서 플라잉 커패시터 전압을 제어할 수 있다. 또한 3비트 플라잉 커패시터 전압 제어회로를 제안하여 부하전류에 따른 3-레벨 벅 변환기의 동작을 최적화할 수 있으며 슈미트 트리거 회로를 이용한 삼각파 생성 회로를 제안하였다. 제안하는 3-레벨 벅 변환기는 $0.18{\mu}m$ CMOS 공정으로 설계되었으며 2.7~3.6V의 공급 전압 범위와 0.7V~2.4V의 출력 전압 범위를 갖는다. 동작 주파수는 2MHz, 부하전류 범위는 30mA~500mA이며 출력 전압 리플은 최대 32.5mV로 측정되었다. 측정 결과 130mA의 부하전류에서 약 85%의 최대 전력변환 효율을 보인다.

계통 연계 기능을 갖는 연료전지 철도차량 보조전원장치의 삼중 루프 전류 제어기 설계 (Design of Triple Loop Current Control for Auxiliary Power Unit of Fuel Cell Train having Grid Connected Inverter Function)

  • 권일섭;백승우;김학원;조관열
    • 전력전자학회논문지
    • /
    • 제25권4호
    • /
    • pp.293-302
    • /
    • 2020
  • This study proposes a triple-loop current control method for the auxiliary power unit of fuel cell trains. The auxiliary power unit of fuel cell trains has a grid-connected function when power is supplied to the utility grid. Moreover, the auxiliary power unit of trains has a 1500 V DC link voltage; thus, PWM frequency cannot be increased to a high frequency. Owing to this low PWM frequency condition, creating a triple-loop design is difficult. In this study, a triple-loop controller is developed for a capacitor voltage controller in standalone mode that operates as an auxiliary power supply for trains and for a grid current controller in grid control mode with an inner capacitor voltage controller. The voltage controller employs an inductor current controller inner loop. To overcome low PWM frequency, a design method for the bandwidth of the capacitor voltage controller considering the bandwidth of the inner inductor current controller is described. The effectiveness of the proposed method is proven using PSIM simulation.

Single-Phase Improved Auxiliary Resonant Snubber Inverter that Reduces the Auxiliary Current and THD

  • Zhang, Hailin;Kou, Baoquan;Zhang, He;Zhang, Lu
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.1991-2004
    • /
    • 2016
  • An LC filter is required to reduce the output current ripple in the auxiliary resonant snubber inverter (ARSI) for high-performance applications. However, if the traditional control method is used in the ARSI with LC filter, then unnecessary current flows in the auxiliary circuit. In addressing this problem, a novel load-adaptive control that fully uses the filter inductor current ripple to realize the soft-switching of the main switches is proposed. Compared with the traditional control implemented in the ARSI with LC filter, the proposed control can reduce the required auxiliary current, contributing to higher efficiency and DC-link voltage utilization. In this study, the detailed circuit operation in the light load mode (LLM) and the heavy load mode (HLM) considering the inductor current ripple is described. The characteristics of the improved ARSI are expressed mathematically. A prototype with 200 kHz switching frequency, 80 V DC voltage, and 8 A maximum output current was developed to verify the effectiveness of the improved ARSI. The proposed ARSI was found to successfully operate in the LLM and HLM, achieving zero-voltage switching (ZVS) of the main switches and zero-current switching (ZCS) of the auxiliary switches from zero load to full load. The DC-link voltage utilization of the proposed control is 0.758, which is 0.022 higher than that of the traditional control. The peak efficiency is 91.75% at 8 A output current for the proposed control, higher than 89.73% for the traditional control. Meanwhile, the carrier harmonics is reduced from -44 dB to -66 dB through the addition of the LC filter.

주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계 (Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter)

  • 이태헌;김종구;소진우;윤광섭
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.864-870
    • /
    • 2017
  • 본 논문은 넓은 부하 전류를 요구하는 휴대 기기에서 사용될 목적으로 주파수 전압 변환을 이용하여 모드 제어 가능한 듀얼 모드 벅 변환기를 설명한다. 기존의 히스테스테릭 벅 변환기의 문제인 저 부하에서의 PLL 보상 및 효율 저하를 제안하는 듀얼 벅 변환기의 개선된 PFM 모드를 통해 해결한다. 또한 기존의 듀얼 모드 벅 변환기의 주요 회로인 모드 제어기에서의 부하 변화 감지의 어려움과 느린 모드 전환 속도를 제안하는 모드 제어기로 개선 시킨다. 제안하는 모드 제어기는 최소 1.5us의 모드 전환 시간을 가진다. 제안하는 DC-DC 벅 변환기는 $0.18{\mu}m$ CMOS 공정에서 설계하였으며 칩 면적은 $1.38mm{\times}1.37mm$이다. 기생 소자를 포함한 인덕터와 커패시터를 고려한 후 모의실험 결과는 1~500mA의 부하 전류 범위에서 입력 전압을 2.7~3.3V를 가지며 PFM 모드는 65mV이내, 히스테리틱 모드에서는 고정된 스위칭 주파수 상태에서 16mV의 출력 리플 전압을 가지는 1.2V의 출력 전압을 생성한다. 제안하는 듀얼 모드 벅 변환기의 최대 효율은 80mA에서 95%를 나타내며 해당 전체 부하 범위에서 85% 이상의 효율을 지닌다.

Improvement of One-Cycle Controller Response with a Current Mode Controller

  • Ruzbehani, Mohsen;Zhou, Luowei;Mirzaei, Nasser
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.21-26
    • /
    • 2010
  • The most important feature of the one-cycle control method is its excellent ability in line disturbance rejection. However, when it is used as a controller in dc-dc converters, it has an undesirable transient response. The voltage overshoot at the transient time, which usually exists in one-cycle controlled converters, is unwanted in many applications and it is sometimes hazardous. In this paper, it is shown that the combination of a one-cycle controller with a current mode controller, can improve the transient response and consequently the overshoot can be controlled. Therefore, the combined controller has the excellent line disturbance rejection of a one-cycle controller and the output current limiting capability of current mode controllers. Because in this scheme a one-cycle controller is the master controller, the problem of instability of current mode control, will not happen. By simulation and a practical prototype, the capability of the method is shown.

적응 슬라이딩 관측기를 이용한 매입형 영구자석 동기전동기의 센서리스 속도제어 (Sensorless Speed Control of IPMSM using an Adaptive Sliding mode Observer)

  • 강형석;김원석;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.271-279
    • /
    • 2006
  • In this paper, a new speed sensorless control based on an adaptive sliding mode observer is proposed lot the interior permanent magnet synchronous motor(IPMSM) drives. With using voltage equation only, the adaptive sliding mode observer was investigated. Since the parameter of the dynamic equation such as machine inertia or viscosity friction coefficient are not well known and these values can be easily changed during normal operation, there are many restrictions in the actual implementation. The proposed adaptive sliding mode observer applied to overcome the problem caused by using the dynamic equation. Furthermore, the Lyapunov function is used to prove the system stability included speed estimate and speed control. The effectiveness of the proposed algorithm is confirmed by the experiments.

Analysis of Parameter Effects on the Small-Signal Dynamics of Buck Converters with Average Current Mode Control

  • Li, Ruqi;O'Brien, Tony;Lee, John;Beecroft, John;Hwang, Kenny
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.399-409
    • /
    • 2012
  • In DC-DC Buck converters with average current mode control, the current loop compensator provides additional design freedom to enhance the converter current loop performance. On the other hand, the current loop circuit elements append substantial amount of complexity to not only the inner current loop but also the outer voltage loop, which makes it demanding to quantify circuit and operating parameter effects on the small-signal dynamics of such converters. Despite the difficulty, it is shown in this paper that parameter effects can be analyzed satisfactorily by using an existing small-signal model in conjunction with a newly proposed simplified alternative. As a result of the study, new insight into average current mode control is uncovered and discussed quantitatively. Measurable experimental results on a prototype averaged-current-mode-controlled Buck converter are provided to facilitate the analytical study with good correlation.

유전자 알고리즘을 이용한 정밀 스테이지의 슬라이딩모드 제어기 설계에 관한 연구 (The Design of Sliding Mode Controller for Precision Stage using Genetic Algolithm)

  • 조백희;성활경
    • 한국생산제조학회지
    • /
    • 제19권1호
    • /
    • pp.101-107
    • /
    • 2010
  • This paper presents motion control of the precision stage composed of the piezoelectric actuator and flexible hinges. The stage shows approximately 27% overshoot when the stage was applied to 30V square wave input voltage. Also, the stage shows nonlinear response characteristics including hysteresis. This paper proposes feedback control technique to suppress the phenomenon of hysteresis and overshoot using the sliding mode control scheme with the integrator. Also, this paper suggests the method that searches important parameters of sliding mode control and observer using Genetic Algorithm. To demonstrate the effectiveness of the proposed control algorithm, experimental validations are performed.

Sliding Mode Current Controller Design for Power LEDs

  • Kim, Eung-Seok;Kim, Cherl-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.104-110
    • /
    • 2011
  • High-brightness LED control is required for stable operation, thus the driver and control system must be designed to deliver a constant current to optimize reliability and ensure consistent luminous flux. In this paper, the sliding mode current controller is designed to adjust the illumination density of power LEDs. The controller design model of power LEDs, including its driving circuit, is proposed to realize the dimming control of power LEDs. A buck converter is introduced to drive the power LEDs and reduce the input voltage to a lower level. The sliding mode software controller is implemented to adjust the dimming of power LEDs. The proposed strategy for driving power LEDs is investigated and comparatively studied by experiments.