• Title/Summary/Keyword: Voltage disturbance

Search Result 248, Processing Time 0.022 seconds

A Word Line Ramping Technique to Suppress the Program Disturbance of NAND Flash Memory

  • Lee, Jin-Wook;Lee, Yeong-Taek;Taehee Cho;Lee, Seungjae;Kim, Dong-Hwan;Wook-Ghee, Hahn;Lim, Young-Ho;Suh, Kang-Deog
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • When the program voltage is applied to a word line, a part of the boosted channel charge in inhibited bit lines is lost due to the coupling between the string select line (SSL) and the adjacent word line. This phenomenon causes the program disturbance in the cells connected to the inhibited bit lines. This program disturbance becomes more serious, as the word line pitch is decreased. To reduce the word line coupling, the rising edge of the word-line voltage waveform was changed from a pulse step into a ramp waveform with a controlled slope. The word-line ramping circuit was composed of a timer, a decoder, a 8 b D/A converter, a comparator, and a high voltage switch pump (HVSP). The ramping voltage was generated by using a stepping waveform. The rising time and the stepping number of the word-line voltage for programming were set to $\mutextrm{m}-$ and 8, respectively,. The ramping circuit was used in a 512Mb NAND flash memory fabricated with a $0.15-\mutextrm{m}$ CMOS technology, reducing the SSL coupling voltage from 1.4V into a value below 0.4V.

  • PDF

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

A Disturbance Observer-Based Robust Controller Against Load Variations in a Single Phase DC/AC Inverter System (단상 DC/AC 인버터 시스템의 부하변동을 고려한 외란 관측기 기반 제어기)

  • Kim, Sung-Jong;Son, Young-Ik;Jeong, Yu-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.110-112
    • /
    • 2007
  • Output voltage waves of a DC/AC inverter system are likely to be distorted if variable loads e.g. motors or rectifiers exist in the output terminal. This paper designs a disturbance observer-based PI controller for a single-phase inverter system that is robust against load changes. In this paper, we regard the output voltage changes due to various loads as disturbances of the control system, Then we design a disturbance observer for estimation of the disturbances caused by the load current and any other error sources (such as parameter uncertainties and model mismatches etc.). In order to test the performance of the proposed control law, simulation studies are carried out for a single-phase inverter system using SimPowerSystems of Matlab Simulink. Compared to a simple PI control, the disturbance observer-based controller shows enhanced performance in transient responses for step load changes.

  • PDF

Performance Improvement of Sensorless Vector Control for Induction Motor Drives Driven By Matrix Converter Using Non-Linearity Compensation and Disturbance Observer (비선형 모델링과 외란 관측기를 이용한 Matrix Converter로 구동되는 유도전동기 센서리스 벡터제어의 성능 개선)

  • Kyo-Beum Lee
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.500-508
    • /
    • 2004
  • This paper presents a new sensorless vector control system for high performance induction motor drives fed by a matrix converter with non-linearity compensation and disturbance observer. The nonlinear voltage distortion that is caused by commutation delay and on-state voltage drop in switching device is corrected by a new matrix converter modeling. The lumped disturbances such as parameter variation and load disturbance of the system are estimated by the radial basis function network (RBFN). An adaptive observer is also employed to bring better responses at the low speed operation. Experimental results are shown to illustrate the performance of the proposed system.

Discrete Time Tracking Control of Motor Based on Disturbance Observer (외란 관측기 기반의 이산시간 전동기 추종제어)

  • Jeon, Yong-Ho;Kang, Jung-Yoog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.511-518
    • /
    • 2021
  • In order to obtain a good tracking performance of the motor, it is necessary to design a controller that can respond to a disturbance by including a disturbance observer. The disturbance observer of the motor is designed to estimate the load torque and the back electromotive voltage based on the first-order low-pass filter. A PI controller and an IP controller were designed to compare the correlation between the disturbance observer and the controller and to obtain improved control performance. To check the performance of the designed observer and the controller, it was applied to a 120 [W] class BLDC motor. As a result, overshoot is reduced, and it can be seen that the steady-state error converges to zero.

Design of a Sense Amplifier Minimizing bit Line Disturbance for a Flash Memory (비트라인 간섭을 최소화한 플래시 메모리용 센스 앰프 설계)

  • Kim, Byong-Rok;So, Kyoung-Rok;You, Young-Gab;Kim, Sung-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2000
  • In this paper, design of sense amplifier for a flash memory minimizing bit line disturbance due to common bit line is presented. There is a disturbance problem at output modes by using common bit line, when the external devices access an internal flash memory. This phenomenon is resulted form hot carrier between floating gates and bit lines by thin oxide thickness. To minimize bit line disturbance, lower it line voltage is required and need sense amplifier to detect data existence in lower bit line voltage. Proposed circuits is operated at lower bit line voltage and we fabricated a embedded flash memory MCU using 0.6u technology.

  • PDF

The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller (전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성)

  • Chung, Yon-Tack;Kim, Won-Chul;Lee, Sa-Young;Chun, Ji-Yong;Kim, Hyeun-Bong;Lee, Keun-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

Reduction of series transformer voltage variation of voltage disturbance generator (전압변동 발생기의 직렬변압기에 의한 전압변동 개선)

  • Nho, E.C.;Lee, Y.H.;Min, B.H.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Choi, N.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.218-220
    • /
    • 2007
  • A new 3-phase voltage disturbance generator is proposed. The voltage drop of the conventional generator in normal mode can be reduced significantly. The output voltage of the proposed generator is constant in normal mode and the efficiency of the series transformer is improved. The proposed generator has good feature of simple structure, cost effective implementation, high reliability, high efficiency, and easy control. The usefulness of the scheme is verified through simulation and experiments.

  • PDF

The Detection of Voltage Sag using Wavelet Transform (웨이브렛 변환을 이용한 Voltage Sag 검출)

  • Kim, Cheol-Hwan;Go, Yeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.9
    • /
    • pp.425-432
    • /
    • 2000
  • Wavelet transform is a new method fro electric power quality analysis. Several types of mother wavelets are compared using voltage sag data. Investigations on the use of some mother wavelets, namely Daubechies, Symlets, Coiflets, Biorthogonal, are carried out. On the basis of extensive investigations, optimal mother wavelets for the detection of voltage sag are chosen. The recommended mother wavelet is 'Daubechies 4(db4)' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. This paper presents a discrete wavelet transform approach for determining the beginning time and end time of voltage sags. The technique is based on utilising the maximum value of d1(at scale 1) coefficients in multiresolution analysis(MRA) based on the discrete wavelet transform. The procedure is fully described, and the results are compared with other methods for determining voltage sag duration, such as the RMS voltage and STFT(Short-Time Fourier Transform) methods. As a result, the voltage sag detection using wavelet transform appears to be a reliable method for detecting and measuring voltage sags in power quality disturbance analysis.

  • PDF

A Voltage Disturbance Generator for the Performance Test of 1-Phase UPS (단상 무정전 전원공급 장치의 성능시험을 위한 전압변동 발생기)

  • Byeon, Woo-Yeol;Nho, Eui-Cheol;Kim, In-Dong;Choi, Nam-Sup;Joung, Gyu-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.146-151
    • /
    • 2005
  • This paper describes a new voltage disturbance generator for the performance test of a 1-phase UPS(Uninterruptible Power Supply). The proposed scheme has the ability of voltage sag, swell, and outage generation. The structure of the proposed generator is simple and cost-effective. The voltage disturbance can be generated with easy control system. The circuit operation and characteristics of the proposed converter are described and the usefulness of the converter is verified through computer simulations and experimental results.