리액터 기동 유도발전기의 동작 특성 해석 (Operating Characteristic Analysis of the Induction Generator by the Reactor Starting)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제63권3호
    • /
    • pp.138-142
    • /
    • 2014
  • In general, the voltage stability of induction generator is lower than synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used little by little in small hydroelectric power station rather than 1000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to increase the penetration of the induction generator, it is necessary to present a method of reducing inrush current. In this study, we suggested that it is possible to present a reactor startup method, by applying the parameter to reduce the voltage drop.

A DVR Control for Compensating Unbalanced Voltage Dips of a DFIG System using Zero Sequence Components

  • Thinh, Quach Ngoc;Ko, Ji-Han;Kim, Dong-Wan;Kim, Eel-Hwan
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.62-68
    • /
    • 2013
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generators based on doubly-fed induction generator (DFIG) that is operated under unbalanced voltage dip conditions. The compensating voltages of the DVR depend on the voltage dips and on the influence of the zero sequence component. The zero sequence component results in high insulation costs and asymmetry in terminal voltages. This paper proposes the use of a proportional-resonant controller in stationary reference frames for controlling zero sequence components in the DVR to protect the DFIG during unbalanced voltage dips. To enhance the proposed control method, a comparison is carried out between two cases: with and without using the control of a zero sequence component. Simulation results are presented to verify the effectiveness of the proposed control method by using the Psim simulation program.

전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법 (High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults)

  • 최형진;송승호;정승기;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

소수력에 적용한 동기발전기와 유도발전기의 운전 특성 비교 (A comparison of the operating characteristics of the synchronous generator and induction generator applied to the small hydroelectric power plant)

  • 김종겸;김영국
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.55-60
    • /
    • 2014
  • In general, A synchronous generator is higher than the voltage stability of the induction generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So, coverage rate of the induction generator is gradually increasing in small hydroelectric power station rather than 1000kW recently. In order to increase the penetration of induction generator, pre-analysis of the operation of the generator is needed. In this study, we analyzed for the problems that occur when synchronous generator and induction generator of 1500kW is connected to the distribution system.

유기전해질에 따른 EDLC의 전기화학적 특성 (Electrochemical Characteristics of EDLC with various Organic Electrolytes)

  • 양천모;이중기;조원일;조병원;임병오
    • 전기화학회지
    • /
    • 제4권3호
    • /
    • pp.113-117
    • /
    • 2001
  • 탄소계 전극을 사용하는 EDLC(Electric Double Layer Capacitor)용의 축전용량과 충방전속도는 전해질의 종류, 충방전 조건 그리고 탄소계 물질의 물리화학적 성질에 따라 크게 달라질 수 있다. 이에 본 연구에서는 dip coating method에 의해 제조된 EDLC용 활성탄소 전극에서 유기 전해질의 종류를 달리하여 충방전 실험과 전기화학적인 실험을 시행하였다. 또한 충전전류밀도와 방전전류밀도의 변화에 따른 비축전 용량의 변화를 조사하였고, 최적 유기전해질의 조건에서 leakage current 특성, 자가방전 특성 그리고 시간전압곡선을 기존의 $1M-Et_4NBF_4/PC$와 비교하였다 활성탄, 소전극으로 비표면적이 $2000m^2/g$인 MSP-20을 사용하고 유기전해질로는 $1M-LiPF_6/PC-DEC(1:1)$를 사용한 EDLC에서 130 F/g 정도의 우수한 비축전 용량을 나타내었고 저항면에서도 가장 낮은 수치를 나타내었다 $1M-LiPF_6/PCDEC(1:1)$를 사용한 EDLC는 15분동안 0.0004A의 낮은 leakage current와 100시간 경과 후 0.8V의 우수한 자가 방전 특성 그리고 IR-drop이 적은 선형의 시간-전압곡선을 보여주었다.

유도전동기의 동특성해석에 있어서의 Time constant parameter에 의한 간이해석법 (Simple analysis on induction motor dynamic performances by time constant parameter)

  • 황영문
    • 전기의세계
    • /
    • 제31권2호
    • /
    • pp.126-131
    • /
    • 1982
  • Induction motors are known to cause voltage dip, oscillating torque and inrush current on the dynamic period. To compensate for these undesirable effects, the prediction of dynamic performances is required. The dynamic performances are determinated by circuit time constants. From this point of view, in this paper, the dynamic equivalent circuit included only three time-constant parameters are presented. To predict more simply dynamic performances, the new characteristics time constant parameters are analyzed, and now these parameters are described as the function of circuit time constants. This paper reviews and analyzes the use of series capacitance compensations, and the use of this analysis can make simply a prediction about oscillating conditions.

  • PDF

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

회전윤법에 의한 에폭시 몰드 절연재료의 내트래킹성 평가 (Tracking Resistance of Epoxy Mold Insulating Materials by the Rotating Wheel Dip Test)

  • 조한구;윤문수;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1590-1592
    • /
    • 2000
  • The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler. the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage. despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT. Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same. It is assumed that this phenomenon is related to the decrease in hydrophobicity of the surface of the materials.

  • PDF

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

계통 연계형 풍력 발전 시스템의 LVRT 제어 전략 (LVRT Control Strategy of Grid-connected Wind Power System)

  • 신호준;설승기
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.182-190
    • /
    • 2011
  • 본 논문은 계통 전압 사고 상황에서 계통 연계형 풍력 발전 시스템이 만족시켜줘야 할 LVRT(Low Voltage Ride Through) 제어 전략을 제안한다. LVRT 규정은 계통 전압 사고 시 풍력 발전 시스템이 지켜야 할 부분들을 전압 감소율과 사고 시간에 대해 나타내고 있다. 특히 전압 감소율이 10% 이상일 경우에는 풍력 발전 시스템은 규정된 무효 전류를 전력 계통에 제공하여 계통 전압 확보에 이바지해야 한다. 본 논문에서의 LVRT 규정은 세계적으로 가장 엄격한 규정인, 독일 계통 연계 규정(German Grid Code)을 기준으로 하고 풀 스케일(Full-scale) 가변 속도 전력 변환 시스템을 고려하여 제어 전략을 수립한다. 본 LVRT 제어 전략은 계통 사고 시 LVRT 규정을 모두 만족시킴과 동시에 직류단 전압 제어의 추가적인 알고리즘으로 직류단 전압의 제어를 통하여 전체 풍력 발전 시스템의 전력 균형을 기할 수 있다. 3상 전압 지락 사고의 경우 계통으로의 전력 제어가 불가능하여 계통 측 컨버터가직류단 전압을 제어할 수 없으므로, 전력 제어의 기능을 발전기 측 인버터로 이행 시켜 상황에 따라 유연한 직류단 전압 제어가 가능함을 보였다. 시뮬레이션과 실험을 통해 LVRT 제어 전략의 타당성을 검증하였다.