• 제목/요약/키워드: Voltage deterioration

검색결과 227건 처리시간 0.022초

누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향 (Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement)

  • 길경석;한주섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

누설전류측정에 의한 피뢰기 열화진단에 있어 전원고조파의 영향 (Influence of Harmonics in Power System Voltage on Arrester Deterioration Diagnostics by Leakage Current Measurement)

  • 길경석;한주섭;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.42-46
    • /
    • 2003
  • Arresters are deteriorated by overvoltages or impulse currents, and the resistive leakage current of arresters increases as the deterioration of the arrester progresses, showing an increase in the 3$^{rd}$ harmonic component of the leakage current. In this reason, arrester diagnostic techniques based on the 3$^{rd}$ harmonic leakage current as a reference parameter of deterioration are widely used. The technique, however, includes an error due to the harmonics of power system voltage. Therefore, the influence of the harmonics on arrester diagnostics should be considered. In this paper, we designed a PSpice ZnO arrester model to simulate the influence of the voltage harmonics described above. A pure sinusoidal voltage and its the 3r harmonic voltage were applied to the model, and the leakage current components were analyzed. From the simulation results, it is confirmed that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. Consequently, the errors caused 1)y the harmonic voltage could be minimized by correcting the magnitude of leakage current upon analyzing the harmonics.cs.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가 (Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT))

  • 문진철;박형기;최충석
    • 한국안전학회지
    • /
    • 제27권4호
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

머신러닝 기법을 이용한 납축전지 열화 예측 모델 개발 (Building battery deterioration prediction model using real field data)

  • 최근호;김건우
    • 지능정보연구
    • /
    • 제24권2호
    • /
    • pp.243-264
    • /
    • 2018
  • 현재 전세계 배터리 시장은 이차전지 개발에 박차를 가하고 있는 실정이지만, 실제로 소비되는 배터리 중 가격 대비 성능이 좋고 재충전을 통해 다시 재사용이 가능한 납축전지(이차전지)의 소비가 광범위하게 이루어지고 있다. 하지만 납축전지는 복합적 셀(cell)을 묶어 하나의 배터리를 구성하여 활용하는 배터리의 특성상 하나의 셀에서 열화가 발생하면 전체 배터리의 손상을 가져와 열화가 빨리 진행되는 문제가 존재한다. 이를 극복하기 위해 본 연구는 기계학습을 통한 배터리 상태 데이터를 학습하여 배터리 열화를 예측할 수 있는 모델을 개발하고자 한다. 이를 위해 실제 현장에서 배터리 상태를 지속적으로 모니터링 할 수 있는 센서를 골프장 카트에 부착하여 실시간으로 배터리 상태 데이터를 수집하고, 수집한 데이터를 이용하여 기계학습 기법을 적용한 분석을 통해 열화 전조 현상에 대한 예측 모델을 개발하였다. 총 16,883개의 샘플을 분석 데이터로 사용하였으며, 예측 모델을 만들기 위한 알고리즘으로 의사결정나무, 로지스틱, 베이지언, 배깅, 부스팅, RandomForest를 사용하였다. 실험 결과, 의사결정나무를 기본 알고리즘으로 사용한 배깅 모델이 89.3923%이 가장 높은 적중률을 보이는 것으로 나타났다. 본 연구는 날씨와 운전습관 등 배터리 열화에 영향을 줄 수 있는 추가적인 변수들을 고려하지 못했다는 한계점이 있으나, 이는 향후 연구에서 다루고자 한다. 본 연구에서 제안하는 배터리 열화 예측 모델은 배터리 열화의 전조현상을 사전에 예측함으로써 배터리 관리를 효율적으로 수행하고 이에 따른 비용을 획기적으로 줄일 수 있을 것으로 기대한다.

직류전압 감쇄성분 측정에 관한 CV케이블의 절연열화 예측 (Diagnostic method of Insulation Deterioration for CV cable Using D.C. Potential Decay Components)

  • 유명호;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.323-328
    • /
    • 1989
  • In this paper, we studied the diagnostic method of insulation deterioration for 22.9kV CNCV cable using D.C potential decay component. At first, arbitrary D.C high voltage is appeied the CNCV cable for two minutes and switched off in vacuum. And then D.C potential decay components is measured for ten minutes. It is detecting source for cable insulation deterioration that its gradient is. Provisionally, we decided the criterion voltage and select the high voltage meter and S.W.

  • PDF

전동기 구동용 IGBT 소자의 열화 진단 (Deterioration Test of IGBT Devices in Motor Driver)

  • 안종곤;박순명;김태기;강주희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.400-405
    • /
    • 2008
  • Motor is energy converting system to generate mechanical force from electrical power and there are various typed motors in home, office, factory, vehicles, aircraft, shipping, etc. Recently in compliance with performance and reliability and the applications of variable speed motors with invert driver are expanded. Almost high power inverter have IGBT and IGBT's fault cause motor system fault. If we can calculate and foresee troubles of IGBT, we can protect accident caused by motor system fault. In this paper, the deterioration test method of IGBT devices is proposed and the test results of proposed method are shown by evaluated equipment. The basic concept of proposed method is current-voltage characteristic curve test between drain and source of IGBT in open state. The applied voltage type is ramp and it is confirmed that the current-voltage curvet pattern of IGBT in open state represents IGBT's deterioration state.

  • PDF

XLPE의 부분방전에 의한 트리진전 특성과 음향방출신호 측정 (Measurement of Tree Growth Characteristics and Acoustics Emission Signals by Partial Discharge in XLPE)

  • 김성규;이상우;이광식;김영훈;김금영;김인식;김이국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1954-1956
    • /
    • 2000
  • In this paper, when void of XLPE was existed, electrical tree was growth in branch-type, and it was growth in bush-type when void of XLPE was not existed. Moreover, charge magnitude of partial discharge by deterioration time of XLPE sample was about proportion to output voltage of AE signals. When void was existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased with increasing deterioration time. However, when void were not existed, charge magnitude of partial discharge, the output voltage Vp-p value of AE signals were increased in fast deterioration time, but it were decreasing at after in middle deterioration time. Frequency spectrum response of AE signal was about 100-250[kHz].

  • PDF

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.