In this paper, we studied the diagnostic method of insulation deterioration for 22.9kV CNCV cable using D.C potential decay component. At first, arbitrary D.C high voltage is appeied the CNCV cable for two minutes and switched off in vacuum. And then D.C potential decay components is measured for ten minutes. It is detecting source for cable insulation deterioration that its gradient is. Provisionally, we decided the criterion voltage and select the high voltage meter and S.W.