• Title/Summary/Keyword: Voltage Control Area

Search Result 301, Processing Time 0.032 seconds

A Power MOSFET Driver with Protection Circuits (보호 회로를 포함한 전력 MOSFET 구동기)

  • Han, Sang-Chan;Lee, Soon-Seop;Kim, Soo-Won;Lee, Duk-Min;Kim, Seong-Dong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.2
    • /
    • pp.71-80
    • /
    • 1999
  • In this paper, a power MOSFET driver with protection circuits is designed using a 2${\mu}m$ high-voltage CMOS process. For stable operations of control circuits a power managing circuit is designed, and a voltage-detecting short-circuit protection(VDSCP) is proposed to protect a voltage regulator in the power control circuit. The proposed VDSCP scheme eliminates voltage drop caused by a series resistor, and turns off output current under short-circuit state. To protect a power MOSFET, a short-load protection, a gate-voltage limiter, and an over-voltage protection circuit are also designed A high voltage 2 ${\mu}m$ technology provides the breakdown voltage of 50 V. The driver consumes the power of 20 ~ 100 mW along its operation state excluding the power of the power MOSFET. The active area of the power MOSFET driver occupies $3.5 {\times}2..8mm^2$.

  • PDF

Experimental Parametric Study on the Rotordynamic Characteristics and Optimal Design of a Flexible Rotor Supported by a Slotted-Ring Electro-Rheological Squeeze Film Damper (슬롯 링 형상을 갖는 전기 유변 스퀴즈 필름 댐퍼로 지지된 연성 로터의 동특성 및 최적설계 파라미터 실험 연구)

  • 이용복;김창호;이남수;최동훈;정시영
    • Tribology and Lubricants
    • /
    • v.16 no.3
    • /
    • pp.157-165
    • /
    • 2000
  • A discharge free Electro-Rheological Squeeze Film Damper (ER-SFD) with predetermined-clearances at leakage ends can inherently eliminate electric discharge problems while still supplying stable leakage control. Test results show that the damping force of the slotted-ring ER-SFD is mainly affected by electric voltage, oil supply pressure, position of the damper and ratio of effective surface area of slotted-rings. As the supply voltage is larger, the amplitudes of both slotted ER-SFD and rotor are decreased at first and second critical speeds. The influence of the oil supply pressure and the effective surface area ratio was shown mainly near the first critical speed. The effective surface area ratio of slotted-rings influences the reduction of flexible rotor vibration. As a result, experimental results confirm that the slotted-ring ER-SFD satisfactorily controls the flexible rotor vibration, while eliminates the inherent electric discharge problems in conventional ER-SFDs.

A Low-voltage Vibration Energy Harvesting System with MPPT Control (MPPT 제어 기능을 갖는 저전압 진동 에너지 하베스팅 시스템)

  • An, Hyun-jeong;Kim, Ye-chan;Hong, Ye-jin;Yang, Min-Jae;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.477-480
    • /
    • 2015
  • In this paper a low-voltage vibration energy harvesting circuit with MPPT(Maximum Power Point Tracking) control is proposed. By employing bulk-driven technique, the minimum operating voltage of the proposed circuit is as low as 0.8V. The designed MPPT control circuit traces the maximum power point by periodically sampling the open circuit voltage of a full-wave rectifier circuit connected to the piezoelectric device output and delivers the maximum available power to load. The proposed circuit is designed using a $0.35{\mu}m\;CMOS$ process, and the chip area including pads is $1.33mm{\times}1.31mm$. Simulation results show that the maximum power efficiency of the designed circuit is 85.49%.

  • PDF

Planning of HVDC System Applied to Korea Electric Power Grid

  • Choi, DongHee;Lee, Soo Hyoung;Son, Gum Tae;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.105-113
    • /
    • 2018
  • This paper proposes pre-analysis on planning of high-voltage direct current (HVDC) transmission system applied to Korea electric power grid. HVDC transmission system for interface lines has been considered as alternative solution for high-voltage AC transmission line in South Korea since constructing new high-voltage AC transmission lines is challenging due to political, environmental and social acceptance problems. However, the installation of HVDC transmission system as interface line in AC grid must be examined carefully. Thus, this paper suggests three scenarios to examine the influences of the installation of HVDC transmission system in AC grid. The power flow and contingency analyses are carried out for the proposed scenarios. Power reserves in metro area are also evaluated. And then the transient stability analysis focusing on special protection scheme (SPS) operations is analyzed when critical lines, which are HVDC lines or high voltage AC lines, are tripped. The latest generic model of HVDC system is considered for evaluating the impacts of the SPS operations for introducing HVDC system in the AC grid. The analyses of proposed scenarios are evaluated by electromechanical simulation.

Centralized Control Algorithm for Power System Performance using FACTS Devices in the Korean Power System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Chang, Byung-Hoon;Myung, Ro-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 2010
  • This paper presents a centralized control algorithm for power system performance in the Korean power system using Flexible AC Transmission Systems (FACTS) devices. The algorithm is applied to the Korean power system throughout the metropolitan area in order to alleviate inherent stability problems, especially concerns with voltage stability. Generally, control strategies are divided into local and centralized control. This paper is concerned with a centralized control strategy in terms of the global system. In this research, input data of the proposed algorithm and network data are obtained from the SCADA/EMS system. Using the full system model, the centralized controller monitors the system condition and decides the operating point according to the control objectives that are, in turn, dependent on system conditions. To overcome voltage collapse problems, load-shedding is currently applied in the Korean power system. In this study, the application of the coordination between FACTS and switch capacitor (SC) can restore the solvability without load shedding or guarantee the FV margin when the margin is insufficient. Optimal Power Flow (OPF) algorithm, for which the objective function is loss minimization, is used in a stable case. The results illustrate examples of the proposed algorithm using SCADA/EMS data of the Korean power system in 2007.

A study on the adhesion of Ag film deposited on Alloy42 substrate (Alloy42 기판 위에 증착된 Ag막의 밀착력에 관한 연구)

  • 이철룡;천희곤;조동율;이건환;권식철
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.4
    • /
    • pp.496-502
    • /
    • 1999
  • Electroplating of Ag and Au on the functional area of lead frames are required for good bonding ability in IC packaging. As the patterns of the lead frame become finer, development of new deposition technology has been required for solving problems associated with process control for uniform thickness on selected area. Sputtering was employed to investigate the adhesion between substrate Alloy42 and Ag film as a new candidate process alternative to conventional electroplating. Coating thickness of Ag film was controlled to 3.5$\mu\textrm{m}$ at room temperature as a reference. The deposition of film was optimized to ensure the adhesion by process parameters of substrate heating temperature at $100~300^{\circ}C$, sputter etching time at -300V for 10~30min, bias voltage of -100~-500V, and existence of Cr interlayer film of $500\AA$. The critical $load L_{c}$ /, defined as the minimum load at which initial damage occurs, was the highest up to 29N at bias voltage of -500V by scratch test. AFM surface image and AES depth profile were investigated to analyze the interface. The effect of bias voltage in sputtering was to improve the surface roughness and remove the oxide on Alloy42.

  • PDF

Direct Load Control Scheme for Congestion Problems in Power System Emergency (비상시 선로혼잡 해결을 위한 직접부하제어)

  • Shin, Ho-Sung;Kim, Byoung-Su;Song, Kyung-Bin;Kim, Jae-Chul;Lee, Hak-Ju;Kwon, Seong-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.307-310
    • /
    • 2005
  • Most of the electric power in the power system of South Korea is flowing from the south area to the north area, Seoul, in the capital of South Korea. Almost of the needs of the electric power in the capital area are about 43% of the total loads and generation plants are mainly located in the south area of South Korea. As mentioned the earlier characteristic, transmission congestion is one of the important research issues. Because of the limits of the power flows from the south to the north which are anticipated to be increased more and more in the future, these congestion situations may cause a serious voltage stability problem in emergency of the power system. Accordingly, we are interested in an interruptible load control program so as to solve this problem in emergency. This problem can be solved by an interruptible load management in emergency, however, the systematic and effective mechanism has not been presented yet. In this paper, the algorithm of interruptible load management plan using the line sensitivity to the loads for the transmission congestion management in emergency is presented. The proposed method is applied to 6-Bus sample system and their results are presented.

  • PDF

Sensorless Control Method in IPMSM Position Sensor Fault for HEV

  • Kim, Sung-Joo;Lee, Yong-Kyun;Lee, Ju-Suk;Lee, Kwang-Woon;Kwon, Taesuk;Mok, Hyungsoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1056-1061
    • /
    • 2013
  • The widely used motors in HEV(Hybrid Electric Vehicles) are IPMSM(Interior Permanent Magnet Synchronous Motor) which has no rotor heat, higher efficiency and advantageous in volume and weight comparing with other motors. For vector control of IPMSM, position information of rotor is required but Resolver is mainly used as the detecting sensor. However, the use of position sensors will reduce the system reliability of hybrid electric vehicles. In this paper, a way to control the motor by sensorless was proposed at the event of sensor failure. We also implemented IPMSM sensorless operation by the expanded EMF(Electro Motive Force) voltage way and harmonic voltage which is applying in the low speed area. And we proposed how to change with sensorless control by detecting the position sensors failure and verified it through experiments.

A Speed Estimation based on the Very Quick Torque Controlmethod of Induction Motors (유도 전동기의 토크 속응 제어방식에 근거한 속도 추정법의 제안)

  • Jeong, Seok Kwon
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.7 no.1
    • /
    • pp.127-132
    • /
    • 1995
  • In this paper, a new speed estimation method of induction motors based on the very quick torque control is proposed to realize speed sensorless control. The proposed method can be realized very simply by detecting primary motor current and voltage command at every sampling time. As the method need not the differential value of primary current in a arithmetic of voltage command, it can be expected to promote the precision of speed estimation in low speed area, especially. Through the numerical simulation, the validity of the proposed method was successfully confirmed.

  • PDF

Microstructure Property of High Voyage Motor Stator Insulation (고압전동기 고정자 권선 절연재료의 미세구조 특성)

  • 김희동;주영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.513-517
    • /
    • 1999
  • High voltage motor(rated 6.6kV and 448kw) has failed in the stator endwinding area during normal service. Experiments on microstructure property were conducted using the control and aged insulations, which were drawn out from stator windings of the high voltage motor. The analyses were characterized using stereozoom microscope(SM), scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy(EDS). SM result shows that large voids are present in the interface between turn insulation and groundwall insulation. SEM results indicated that the groundwall insulation is rarely thermal stress. EDS results showed that chemical elements in the high voltage motor stator insulations were Al, Si, O, K and Fe.

  • PDF