Microstructure Property of High Voyage Motor Stator Insulation

고압전동기 고정자 권선 절연재료의 미세구조 특성

  • Published : 1999.05.01

Abstract

High voltage motor(rated 6.6kV and 448kw) has failed in the stator endwinding area during normal service. Experiments on microstructure property were conducted using the control and aged insulations, which were drawn out from stator windings of the high voltage motor. The analyses were characterized using stereozoom microscope(SM), scanning electron microscope(SEM) and energy dispersive X-ray spectroscopy(EDS). SM result shows that large voids are present in the interface between turn insulation and groundwall insulation. SEM results indicated that the groundwall insulation is rarely thermal stress. EDS results showed that chemical elements in the high voltage motor stator insulations were Al, Si, O, K and Fe.

Keywords