• Title/Summary/Keyword: Vibration Power

Search Result 2,769, Processing Time 0.027 seconds

Vibration Reduction Method for Discharge Line of Moisture Separator Reheater (습분분리재열기 배수관 진동저감방안)

  • 이준신;손석만;김태룡
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

Wind-induced vibration control of a 200 m-high tower-supported steel stack

  • Susuki, Tatsuya;Hanada, Naoya;Homma, Shin;Maeda, Junji
    • Wind and Structures
    • /
    • v.9 no.5
    • /
    • pp.345-356
    • /
    • 2006
  • It is well known that cylinder steel stacks are heavily impacted by vortex-induced vibration. However, the wind-induced vibration behaviors of tower-supported steel stacks are not clarified due to a lack of observation. We studied a stack's response to strong winds over a long period of time by observing the extreme wind-induced vibration of a 200 m-high tower-supported steel stack. This experiment aimed to identify the wind-induced vibration properties of a tower-supported steel stack and assess the validity of the vibration control method used in the experiment. Results revealed a trend in wind-induced vibration behavior. In turn, an effective measure for controlling such vibration was defined by means of increasing the structural damping ratio due to the effects of the tuned mass damper to dramatically decrease the vortex-induced vibration of the stack.

Real-time Vibration Control of Cable Bridges using a Shear-type MR Damper-Focusing on Power Model and Lyapunov Control (전단형 MR 댐퍼를 이용한 케이블 교량의 실시간 진동제어-파워 모델 및 리야프노브 제어 중심으로)

  • Heo, Gwanghee;Lee, Chinok;Jeon, Seunggon;Kim, Chunggil;Jeon, Joonryong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.215-226
    • /
    • 2017
  • In this paper, an experimental study was carried out for vibration control of cable bridges with structurally flexible characteristics. For the experiment on vibration control, a model bridge was constructed by reducing the Seohae Grand Bridge and the shear type MR damper was designed using the wind load response measured at Seohae Grand Bridge. The shear type MR damper was installed in the vertical direction at the middle span of the model bridge, and dynamic modeling was performed using the power model. The tests of the vibration control were carried out by non-control, passive on/off control and Lyapunov control method on model bridge with scaled wind load response. The performance of the vibration control was evaluated by calculating absolute maximum displacement, RMS displacement, absolute maximum acceleration, RMS acceleration, and size of applied power using the response (displacement, acceleration, etc.) from the model bridge. As a result, the power model was effective in simulating the nonlinear behavior of the MR damper, and the Lyapunov control method using the MR damper was able to control the vibration of the structure and reduce the size of the power supply.

Self-Powered Integrated Sensor Module for Monitoring the Real-Time Operation of Rotating Devices (회전기기 실시간 동작상태 모니터링을 위한 자가발전 기반 센서모듈)

  • Kim, Chang Il;Yeo, Seo-Yeong;Park, Buem-Keun;Jeong, Young-Hun;Paik, Jong Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.311-317
    • /
    • 2019
  • Rotating devices are commonly installed in power plants and factories. This study proposes a self-powered sensor node that is powered by converting the vibration energy of a rotating device into electrical energy. The self-powered sensor consists of a piezoelectric harvester for self-power generation, a rectifier circuit to rectify the AC signal, a sensor unit for measuring the vibration frequency, and a circuit to control the light emitting diode (LED) lighting. The frequency of the vibration source was measured using a piezoelectric-cantilever-type vibration frequency sensor. A green LED was illuminated when the measured frequency was within the normal range. The power generated by the piezoelectric harvester was determined, and the LED operation was assessed in terms of the vibration frequency. The piezoelectric harvester was found to generate a power of 3.061 mW or greater at a vibration acceleration of 1.2 g ($1g=9.8m/s^2$) and vibration frequencies between 117 and 123 Hz. Notably, the power generated was 4.099 mW at 122 Hz. As such, our self-powered sensor node can be used as a module for monitoring rotating devices, because it can convert vibration energy into electrical energy when installed on rotating devices such as air compressors.

Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site (발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명)

  • Kim, Yeon-Whan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

A Case Study on High Vibration in a Condensate Pump for Combined Cycle Power Plants (복합 화력 Condensate Pump 의 고진동 사례 분석 및 대책)

  • 최성필;류석주;하현천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.510-513
    • /
    • 2001
  • Several kinds of vibration problems have been frequently encountered in industrial vertical pumps in spite of their widespread use for long time. In fact, vibration problems of the vertical pumps are so complicated and difficult with compared to those of the horizontally mounted pumps that more careful attention should be taken for solving the vibration problems. This paper introduces a case study experienced from troubleshooting for excessive vibration occurred in a vertical-type condensate pump for combined cycle power plants. Subsynchronous whirl vibration was caused by the instability of the guide bearing whose lubricant is water. A newly modified guide bearing has solved the vibration problem, which should be the best countermeasure.

  • PDF

Examination of the Intermittent High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant (발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 간헐적 고진동 현상 규명)

  • 양승헌;박철현;김재실;하현천
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.190-195
    • /
    • 2002
  • The intermittent high vibration has been occurred one or two times a day for a 500MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the intermittent high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

  • PDF

Examination of the Periodic High Vibration by the Accumulated Carbide at Oil Deflector of a Steam Turbine for Power Plant (발전용 증기터빈의 Oil Deflector부 탄화물 퇴적에 의한 주기적 고진동 현상 규명)

  • 양승헌;박철현;김재실;하현천
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.11
    • /
    • pp.897-903
    • /
    • 2002
  • The periodic high vibration has been occurred one or two times a day for a 500 MW large steam turbine during 5 months. This abnormal vibration was caused by the rubbing between the rotor and the carbide accumulated on the seal tooth of oil deflector. It was found that the accumulated carbide was insulation material installed on the HIP casing from the examination of the chemical composition. Also, this paper presents the mechanism of the periodic high vibration and the proper method to eliminate this vibration problem. This result would be good practice to find the solution of similar high vibration in the steam turbines for power plant as well as industrial rotating machineries.

Study on the Buoy and Vibration System in Broadband Ocean Wave Power Generator (광대역 파력발전기의 진동시스템과 부양 체에 대한 연구)

  • Lee, Hong-Chan;Yea, Kyung-Soo;Hwang, Sung-Il;Han, Ki-Bong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.780-787
    • /
    • 2012
  • In general, the ocean wave vibration power generator consists of buoy, vibration system and linear generation system. It maximized energy efficiency by using resonance phenomenon that turned to the natural frequency of vibration system and frequency of ocean wave energy. But it is difficult to obtain efficiently energy from ocean wave because the frequency of ocean wave changes from moment to moment. In this paper, we study the buoy and vibration system of ocean wave power generator to solve these problem. Firstly, we designed the buoy that gives rise to resonance between ocean wave and buoy. Secondly, we designed vibration system that is occurred to resonance between buoy and vibration system. And then the relative velocity between the buoy and magnetic of ocean wave vibration generator increases and the relative displacement between buoy and ocean wave decreases at the same time. As a result, the method which is proposed in this paper has merits not only securing its stability from harsh ocean wave environment but also obtaining more kinetic energy from ever-changing ocean wave.

A Safety Evaluation Study by Vibration Analysis for Shutdown Cooling Piping System (원전 정지냉각계통 배관 진동안전성 평가연구)

  • Lee, Wook-Ryun;Lee, Jun-Shin;Sohn, Soek-Man;Kim, Man-Hee;Song, Seong-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.41-45
    • /
    • 2007
  • Palo Verde Unit 1 nuclear power station which is located in Arizona, USA had been operating at reduced power levels around 25% since December 25, 2005 due to vibration in one of its shutdown cooling lines. During an outage from March 18, 2006 to July 7, 2006 the necessary work and modifications to remedy the situation were performed. It cost approximately $46million to buy electricity to replace that lost as a result of this event. Therefore in this study, the vibration of shutdown cooling lines in the same nuclear power plant in Korea as Palo Verde Unit 1 should be measured by the operating condition of power plant. And it was evaluated using the expression for allowable velocity in ASME OM-S/G-2003. From the result of this study it is evaluated whether it is safe or not. If not the countermeasure should be considered in this study.

  • PDF