A Safety Evaluation Study by Vibration Analysis for Shutdown Cooling Piping System

원전 정지냉각계통 배관 진동안전성 평가연구

  • 이욱륜 (한국전력연구원 원자력발전연구소) ;
  • 이준신 (한국전력연구원 원자력발전연구소) ;
  • 손석만 (한국전력연구원 원자력발전연구소) ;
  • 김만희 (한국수력원자력주식회사) ;
  • 송승용 (한국수력원자력주식회사)
  • Published : 2007.05.10

Abstract

Palo Verde Unit 1 nuclear power station which is located in Arizona, USA had been operating at reduced power levels around 25% since December 25, 2005 due to vibration in one of its shutdown cooling lines. During an outage from March 18, 2006 to July 7, 2006 the necessary work and modifications to remedy the situation were performed. It cost approximately $46million to buy electricity to replace that lost as a result of this event. Therefore in this study, the vibration of shutdown cooling lines in the same nuclear power plant in Korea as Palo Verde Unit 1 should be measured by the operating condition of power plant. And it was evaluated using the expression for allowable velocity in ASME OM-S/G-2003. From the result of this study it is evaluated whether it is safe or not. If not the countermeasure should be considered in this study.

Keywords