• 제목/요약/키워드: Vibration Level

검색결과 2,075건 처리시간 0.023초

발사시 야기되는 랜덤진동을 고려한 위성체 전장품 설계 및 검증에 대한 연구 (Design Consideration and Verification on Random Vibration of Satellite Electronic Equipment while Launching)

  • 김홍배;서현석
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.971-976
    • /
    • 2000
  • High level random vibration environments induced while launching of spacecraft can damage sensitive electronic equipment, unless the equipment is properly packaged. Thus careful consideration on the launch environment, especially for high level random vibration, is required in the design stage of electronic equipment of spacecraft. This paper describes the development process of Solar Array Regulator for KOMPAT-2, which is designed and tested by Korean engineers. Both analytical and experimental techniques are introduced in this paper.

  • PDF

공동주택의 바닥 충격 진동 해석을 위한 유한요소법 응용 (Application of Finite Element Method to Floor Impact Vibration Analysis in the Apartment Buildings)

  • 서상호;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.387-390
    • /
    • 2005
  • Finite element method was applied to the vibration analysis of concrete slab system in apartment building. To save the time and cost the 2 dimensional finite element model was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Second, there is linear relationship between the impact sound pressure level and vibration acceleration level. Third, 2 dimensional finite element model was enough to analyze the vibration analysis of floor structure system.

  • PDF

서울 지하철 건설의 발파기술 발전 (ON THE DEVELOPMENT OF EXPLOSION TECHNOLOGY IN SEOUL METRO SUBWAY CONSTRUSTION)

  • 許眞
    • 화약ㆍ발파
    • /
    • 제18권1호
    • /
    • pp.59-70
    • /
    • 2000
  • The blasting work to construct a subway in seoul, korea have often cased increased neighbor's complaints because of ground vibration. In order to prevent the demage to the stucture it was necessary to predict the level of blasting induced vibration and to determine the maximum charge weigh per delay with an allowable vibration level. The effect of blasting pattem, rock strength and different explosive on the blast-induced ground vibration was studied to determine the maximum charage weight per delay within a given vibration level. The blasting vibration equation from over 100 test data was obtained, V= K(D/W(equation omitted), where the values for n and K are estimated to be 1.7 to 1.5 and 48 to 138 respectively.

  • PDF

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

습분분리재열기 배수관 진동저감방안 (Vibration Reduction Method for Discharge Line of Moisture Separator Reheater)

  • 이준신;손석만;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.688-694
    • /
    • 2001
  • The 84m discharge line of moisture separator reheater(MSR) in Kori-2 had been suffered by excessive vibration from the beginning of power generation. In 1993, a complementary measure was taken to reduce the vibration level by adding several supports in the MSR pipeline. However, the piping vibration was beyond the allowable limit and an appropriate countermeasure was required to prevent the fatigue failure of the pipeline from the abnormal vibration. In this study, the vibrational characteristics of MSR pipeline and the countermeasure for abnormal vibration was investigated. Among the several vibration reduction methods, piping layout change by smoothing the pipeline was applied to the MSR pipeline in Kori-2. Applying the countermeasure, the vibration level was found to dramatically reduce from 17cm/sec to l.0cm/sec at the full-power operation condition.

  • PDF

화력발전소 보일러 급수용 펌프 배관계의 이상소음 저감에 관한 연구 (Study on Noise Control for Piping System of BFP in a Power Plant)

  • 양경현;조철환;배춘희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.490-494
    • /
    • 2004
  • The purpose of this paper was to identify the mechanism that caused abnormal vibration and noise on the piping system connected to discharge flow of BFP(Boiler Feed water Pump) in a coal fired power plant, and to develop the device that can reduce the level of abnormal vibration and noise. Major results of this project can be summarized as follows: First, we analyzed the acoustic mode for the discharge piping of BFP to trace a path of the noise, and assumed that noise and vibration on the piping system can be related with length of pipe. Second, a minimized model of the piping system was set up to simulate abnormal vibration and noise within the specific range of operating frequencies, and as a result we confirmed that the acoustic mode affected the piping system considerably. Finally the test device which can reduce the level of abnormal noise and vibration was built to verify validity applying for the piping system. Then we concluded that the noise and vibration generated from the piping system was attributed to the acoustic resonance in piping system, and so developed new device which can reduce the level of noise and vibration under 40%. Put Abstract here.

  • PDF

가속도가 포함된 순간최적제어 알고리듬을 이용한 구조물 진동의 능동제어 (Active Control of Structural Vibration Using An Instantaneous Control Algorithm including Acceleration Feedback)

  • 문석준;정태영
    • 소음진동
    • /
    • 제6권2호
    • /
    • pp.215-224
    • /
    • 1996
  • Active vibration control is generally used to reduce vibration level by the actuators based on measured signal. Dynamic properties of a structure can be easily modified by the active vibration control, so that the vibration level may be effectively reduced to the magnitude below the allowable limit over a wide frequency rangs. In this paper, an instantaneous optimal control algorithm including acceleration feedback is presented for the active vibration control of large structures considering facts that the acceleration response can be easily measured, but the displacement and velocity response are obtained by numerically integrating the measured acceleration response with some errors. The adverse effect of the time delay is overcomed by taking into account the dynamic characteristics of an actuator and filters in the design of controller. Performance test is carried out using a hydraulic active mass driver on a test structure$(L{\times}W{\times}H;=;1200mm{\times}800mm{\times}1600mm, about;500kg)$ supported by four columns under base excitations. It is confirmed that the vibration level of the test structure are reduced to about 1/6 near resonance.

  • PDF

지하철 운행에 따른 진동특성에 관한 연구 (A Study on the characteristics of vibration induced by Subway operation)

  • 배동명;신창혁;이창훈;박상곤
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.332-339
    • /
    • 2000
  • In this paper the characteristics of vibration induced by subway trains running on track is discussed. The quantitative prediction of the vibration level and the countermeasure for reduction of necessary, is of importance for the better environment. It was made the constructed Bundang line as first step with the modified Young-Dan type to basis on the Japanese Young-Dan type. In this paper it was measured and analyzed to two region (①Susuh-Bokjung, ②Chorim-Suhyun region) of this, at present operational Bundang line when averaging velocity of train is 60(㎞/h). As the response characteristics of frequency induced by subway operation, it was confirmed that frequency band of neighborhood of 30∼80Hz in generally dominant. Also to assess the quantitative vibration as response level to be measured for each point of two region in subway operation, the vibrational response level was measured at the state to be not subway operation. And the level was approximately 1/5∼1/10 level comparing to subway operation.

  • PDF

지게차 진동저감을 위한 최적설계 (Dynamic Response Optimization for Vibration Reduction of the Fork-Lift Truck)

  • 이동일;최형우;박근배;이승구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1996년도 춘계학술대회논문집; 부산수산대학교, 10 May 1996
    • /
    • pp.155-160
    • /
    • 1996
  • The vibration analysis of the automobiles has been a good subject for the engineers seeking solutions for more comfortable life. In the area of industrial vehicles, however, the seriousness of the vibration annoyance has not been considered so much. In this paper, a finite element model was built which was good for the low-frequency system(of fork-lift truck), and a forced vibration analysis was obtained for the component of 2n of harmonic orders from engine excitation to this model. Finally, a design optimization upon dynamic responses was made to minimize the vibration acceleration level at selected points representing the vibration level of the whole system.

  • PDF

환경진동의 전달경로 대책 (A Plan on Propagation Process of Environment Vibration)

  • 이성호;이주원;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.635-641
    • /
    • 2001
  • This study introduces the basic concepts of the vibration reducing methods and presents a case study of 'A' apartment construction site which located nearby railroad. The site is only 60m away from the railroad. Therefor much noise and vibration damages could be expected during train or any other transportation's passing. Especially, the first and second floor may suffer much vibration with the low frequency radiation noise from the walls and floors. This study estimates the noise level of indoor area by measuring the vibration of indoor walls and floors. From this result, vibration barrier, as a method to reduce the noise level which exceeds proper standard value, was attempted to protect vibration transmit from the railroad.

  • PDF