• Title/Summary/Keyword: Valve Gate

Search Result 77, Processing Time 0.021 seconds

A Method of ROL Improvement for the Motor Operated Gate Valve Operated in the High Differential Pressure Condition (고차압에서 운전되는 모터구동 게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Yoo, S.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.1 s.28
    • /
    • pp.16-22
    • /
    • 2005
  • This paper presents the method of ROL(Rate Of Loading) improvement for the Motor Operated Gate Valve operated in high differential pressure condition. ROL is one of the most important evaluation parameters for the valve ability. It is close to correlation in stem factor (SF) and appears different value by the differential pressure of fluid. ROL and SF are analyzed by the static test and dynamic test. The obtained result show that the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of SF between static and dynamic test, stem and stem nut should be combined appropriately by the repetition test.

A Method of ROL Improvement for the Motor Operated Gate Valve Operating in the High Differential Pressure Condition (고차압에서 운전되는 모터구동게이트밸브의 부하율 향상 방안)

  • Kim, D.W.;Park, S.G.;Hong, S.Y.;Yooh, S.Y.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.562-567
    • /
    • 2003
  • This paper presents the method of Rate of Loading(ROL) improvement for the Motor Operated Gate Valve operating in high differential pressure condition. The character of ROL and Stem Factor is analyzed. Static test and dynamic test were performed and acquired the diagnosis signal for the valve closing stroke. The result of this study is the modification of stem factor is very important factor for the ROL improvement. In order to obtain the same value of dynamic test thread friction coefficient stem and stem nut should be combined appropriately.

  • PDF

Study for the Energy Efficiency of Hydraulic System of Turnover-Type Sluice Gate (전도 수문용 유압장치의 에너지 효율에 관한 연구)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1225-1230
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the hydrauic system. The hydraulic system may be a open circuit type or a closed circuit type. The open circuit type hydraulic system is composed of a uni-directional pump, a directional control valve, pilot operated check valves, flow control valves, single-rod cylinders. The closed circuit type hydraulic system is composed of a bi-directional pump, pilot operated check valves, check valves, a counter balance valve, single-rod cylinders. The energy efficiencies of two hydraulic systems for the turnover-type sluice gate are compared here.

  • PDF

Dynamic Analysis on the Tail Gate System for Vehicle with the Energy Regenerative Brake of Hydraulic Driven Systems (유압 구동계 에너지 재생 브레이크를 적용한 자동차 테일게이트 개폐장치에 대한 동특성 해석)

  • Choi, Soon-Woo;Huh, Jun-Young
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.2
    • /
    • pp.19-26
    • /
    • 2010
  • The typical trunk lid system for vehicle is composed of a hinge having 4-bar link and gas lifter. Here, the energy regenerative brake of hydraulic driven systems is applied to the tail gate system for vehicle and removed the gas lifter. The new tail gate system is composed of a hydraulic pump by electric motor, a hydraulic motor, four check valves, an accumulator, a relief valve and a directional control valve. The dynamic characteristics of the hydraulic motor system, such as the surge pressure and response time, are investigated in both brake action and acceleration action. The capacity selection method of accumulator by mathematical model is based upon trial and error approach and computer simulation by AMEsim software is carried out.

  • PDF

자동차 범퍼 금형에서 밸브게이트 시스템 적용에 관한 연구

  • 황시현;김명기;정영득
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.115-115
    • /
    • 2004
  • 최근에는 자동차용 범퍼(Bumper), 인판넬(In-panel), 도어판넬(Door panel), 도어가니쉬(Door Garnish) 등과 같은 대형 사출성형품을 성형하기 위한 금형설계에 핫 러너 시스템(Hot Runner System)에 밸브 게이트(Valve Gate)를 채용한 밸브 게이트 시스템을 많이 사용하고 있다 이 시스템을 사용함으로서 성형 싸이클타임의 단축, 수지 스크랩의 감소 등의 말은 장점이 있으나, 실제 성형작업 적용 시 밸브 게이트의 작동순서 및 개폐시간의 제어 등에 정확한 표준이 없어 시험 사출시 최적 성형조건의 셋팅이 많은 시간을 소모하고 있는 문제점이 있다.(중략)

  • PDF

Determination of Valve Gate Open Timing for Minimizing Injection Pressure of an Automotive Instrument Panel (자동차용 인스트루먼트 패널의 사출압력 최소화를 위한 밸브 게이트 열림 시점 결정)

  • Cho, Sung-Bin;Park, Chang-Hyun;Pyo, Byung-Gi;Choi, Dong-Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.46-51
    • /
    • 2012
  • Injection pressure, an important factor in filling process, should be minimized to enhance injection molding quality. Injection pressure can be controlled by valve gate open timing. In this work, we decided the valve gate open timing to minimize the injection pressure. To solve this design problem, we integrated MAPS-3D (Mold Analysis and Plastic Solution-3Dimension), a commercial injection molding CAE tool, to PIAnO (Process Integration, Automation and Optimization), a commercial PIDO (Process Integration, and Design Optimization) tool using the file parsing method. In order to reduce computational cost, we performed an approximate optimization using meta-models that replaced expensive computer simulations. At first, we carried out DOE (Design of Experiments) using OLHD (Optimal Latin Hypercube Design) available in PIAnO. Then, we built Kriging models using the simulation results at the sampling points. Finally, we used micro GA (Genetic Algorithm) available in PIAnO. Using the proposed design approach, the injection pressure has been reduced by 13.7% compared to the initial one. This design result clearly shows the validity of the proposed design approach.

The Study of the Cavitation for the Urgency Released Valve in Hydraulic Dam (수력댐 비상방류밸브에 대한 캐비테이션에 대한 연구)

  • Roh, Hyung-Woon;Lee, Young-Ho;Lee, Kab-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.5 s.38
    • /
    • pp.14-21
    • /
    • 2006
  • In general, the hollow jet valve, the fixed cone valve had been used for the urgency released or maintenance of the flow rate. Nowadays, the butterfly valve, the gate valve are applied in economic performance and operation maintenance more than the hollow jet valve, the fixed cone valve. However, in the case of butterfly valve, it should be required the strict application standard to the cavitation coefficient because the structural axis and disk were situated in pipe channel and the occurring the shock problem by Karman Vortex. Therefore, there were investigated the valve cavitation and accident investigation by field survey to establish the applicable extensibility of the urgency released valve as the preliminary study.

A Study on Performance Characteristics of Wetted-type Multi Path Ultrasonic Flowmeter (습식 다회선 초음파유량계의 특성평가 연구)

  • Lee, Dong-Keun;Cho, Yong;Ko, Jae-Myoung;Park, Tae-Jin;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.4
    • /
    • pp.5-9
    • /
    • 2013
  • An experimental investigation has been carried out in order to evaluate characteristics of wetted-type multi-path ultrasonic flowmeters. The multi-path ultrasonic flowmeters were installed at various entrance and exit locations for several cases of pipe fitting(straight, $90^{\circ}$ double elbow) and valve(gate valve, butterfly valve). We measured the flow-rate at each location. The measurement data of test flowmeter were compared with the measured data of reference flowmeter. The uncertainties of reference flowmeter and test flowmeter are 0.3 %, 0.4 %, respectively. The results demonstrate the effects of flowmeter location as well as the measurement errors in flow rate. The distance between the flow disturbance factor and a flowmeter was an important element of the test.

Study on the Rate-of-Loading by the Differential Pressure of Motor Operated Gate Valves in Opening Stroke (모터구동 게이트밸브의 열림행정시 차압 작용에 의한 부하율 연구)

  • Kim, Bum-Nyun;Hong, Sung-In
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.35-41
    • /
    • 2007
  • The rate of loading in motor operated valve(MOV) can be defined as a variation of correlation between the actuator torque and the thrust upon the variation of operating load. This paper contains the analysis of characteristic and the validity of loading rate in the opening stroke of gate type motor operated valve. Also, this paper describes the evaluation result of loading rate for 40 MOVs' opening stroke using newly derived methodology in this study. Author has found a result that loading rate of opening stroke gets a negative value when the differential pressure is higher than 150 psi and this value goes up depending on the amount of the differential pressure.