• Title/Summary/Keyword: Value Measurement

Search Result 4,756, Processing Time 0.034 seconds

Effect of Measurement Error on the Determination of the Optimal Process Mean for a Canning Process (캔 공정의 최적공정평균을 결정하는데 있어서 측정오차의 영향)

  • Hong, Sung-Hoon;Lee, Min-Koo
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.2
    • /
    • pp.41-50
    • /
    • 1994
  • Consider a canning process where cans are filled with an expensive ingredient. Cans weighting above the specified limit are sold in a regular market for a fixed price, and underfilled cans are emptied and refilled at the expense of a reprocessing cost. In this paper, the effect of measurement error on the determination of the optimal process mean for a canning process is examined. It is assumed that the quantity X of ingredient in a can is normally distributed with unknown mean and known variance, and the observed value Y of X is also normally distributed with known mean and variance. A profit model is constructed which involves selling price. cost of ingredients, reprocessing cost. and cost from an accepted nonconforming can, and methods of finding the optimal process mean and the cutoff value on Y are presented. It is shown that the optimal process mean increases. and the expected profit decreases when the measurement error is relatively large in comparison to the process variance.

  • PDF

Development of Bridge Warning System by Using GPS Surveying Method (GPS측량기법을 이용한 교량경보시스템 개발)

  • 서동주;노태호;이종출
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.20 no.4
    • /
    • pp.415-421
    • /
    • 2002
  • A recently lot of facilities have been constructed from rapidly development of science and economic growth. Among them, bridges are tending to be large because of geometrical problems of the road. And then the method of satellite surveying is being practical use variously out of present surveying methods. Therefore in this study it takes a measurement of bridge displacement using the RTK GPS Mode instead of the using mechanical measurement system. The observation value was verified by using Total Station to inspect observation value of RTK GPS. And then, by using the Delphi of object intending language, developed bridge warning system and applied it. The result of this study was found verification error of 0.2~8.3mm, therefore the measurement of bridge displacement of grand bridge can be applied by using An GPS.

Measurement and Statistical Analysis of Magnetic Fields Produced by Cloud Discharges (운방전에 의해 발생되는 자장의 계측과 통계적 분석)

  • Lee Bok-Hee;Gil Hyoung-.Jun;Cho Sung-Chul;Shim Eung-Bo;Woo Jung-Wook
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.262-268
    • /
    • 2005
  • In this work, to obtain the detailed information about lightning electromagnetic field waveforms, the LabVIEW based-measurement system of time-changing magnetic fields was designed and constructed. The frequency bandwidth of the magnetic field measuring system ranges from 300 [Hz] to 1 [MHz], and the response sensitivity is 2.78 [mV/nT]. Data acquisition system with the resolution of 12 bits and memory capacity of 32 [Mbyte] was triggered by the magnetic field to be measured. The properties and parameters of the magnetic fields produced by cloud discharges were statistically investigated. The magnetic field waveforms radiated from cloud lighting discharges tend to be bipolar, with two or more narrow and several pulses superimposed on the initial front part. The recording length of the magnetic field measurement system is about 10 [ms]. The mean duration of cloud discharges is 1.3 [ms], and the number of outburst pulses for the period is 8 in average. The front times of the magnetic fields are 6.15 [$\mu$s] in average. The the zero-to-zero crossing times that is the initial half-cycle duration is widely dispersed and the mean value is 9.61 [$\mu$s], and the mean value of percentage depth of dip to opposite polarity is 41.1 [$\%$].

Selection of Optimum Fulcrum Type for Measurement and Geo-statistical Analyze of Elevation within Rice Paddy Field (수도작 포장의 고저차 측정을 위한 최적 받침대 선정)

  • Sung J. H.;Jang S. W.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.5 s.112
    • /
    • pp.268-273
    • /
    • 2005
  • This study was conducted to investigate the specificities of four fulcrum types for geo-statistical analysis of elevation within rice paddy field. In Korea, the spaces between inter-rows and between hills for rice transplanting are 30cm and 11cm to 14cm, respectively. So, the size and shape of fulcrum for field elevation measurement should be considered according to the inter-row and the hill spaces. Four kinds of fulcrum were chosen such as round-shape with 2.5cm diameter, circular-shape with 10cm diameter, 10cm (one third of inter-row space) by 24cm (double of hill space) rectangular-shape, and 20cm (two-thirds of inter-row space) by 24cm rectangular-shape. The resulting descriptive statistics couldn't determine the best fulcrum type to measure the rice paddy field elevation. But the results of geo-statistical analysis could determine the best fulcrum type. In the case of 10cm by 24cm rectangular-shape fulcrum, Nugget and range, meaning measurement error and/or noise, and limit of spatial connection, respectively, were minimum; Q value meaning weight of spatial structure and $r^2$ value were minimum, and residual sum of squares was minimum. It means that 10cm by 24 cm rectangular-shape fulcrum could best describe the rice paddy field elevation.

The measurement and analysis of Regenerative Pump Noise (재생펌프 소음특성의 측정 및 해석에 관한 연구)

  • Kim, Tae-Hoon;Seo, Young-Soo;Jeong, Weui-Bong;Jeong, Ho-Kyeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1067-1071
    • /
    • 2004
  • In this paper, the characteristic of the regenerative pump is reviewed by the measurement and the analysis. The dominant noise sources are harmonic components of the rotating impeller frequency. The acoustic characteristics and the noise source position at the dump are identified. In order to reduce the high-level peak noise, the interior flow of the pump chamber is analyzed by CFD (Computational Fluid Dynamics). Acoustic pressure is calculated with Ffowscs Williams and Hawkings equation. As the result of the analysis new design of the pump chamber is recommended. The recommended pump is compared with original pump by evaluating the RMS value of a interior static pressure and the sound pressure level. The new pump chamber recommended by analysis results is proved by a process of the measurement. The overall SPL of a recommended pump is reduced about 3 dBA.

  • PDF

X-Ray Reflectivity Analysis Incorporated with Genetic Algorithm to Analyze the Y- to X Type Transition in CdA LB Film

  • 최정우;조경상;이희우;이원홍;이한섭
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.549-553
    • /
    • 1998
  • The structure and layer distribution of cadmium arachidate Langmuir-Blodgett film were analyzed by the small angle X-ray reflectivity measurements using synchrotron radiation. Y-to X type transition was ocurred during the 39th passage of deposition of cadmium arachidate. Based on the measurement of the consumed area of the monolayer, it was determined that about 27.5 layer was deposited. Using the synchrotron X-ray, the reflectivity profile of cadmium arachidate LB film over the wide range of grazing angle was obtained. The X-ray reflectivity profile was analyzed using the recursion formula. By fitting the location and dispersion of the subsidiary maxima between the Bragg peaks of the measured reflectivity profile with that of the calculated reflectivity profile, the average thickness and the distribution of layer thickness were evaluated. The genetic algorithm was adopted to the fitting of reflectivity profile to evaluate the optimum value of the number distribution of layer. Based on the morphology measurement with an atomic force microscopy (AFM), the domain structure and mean roughness of LB films were obtained. The mean roughness value calculated based on the number of layer distribution obtained from the measurement by AFM is consistent with that obtained from X-ray reflectivity analysis.

The software quality measurement based on software reliability model (소프트웨어 신뢰성 모델링 기반 소프트웨어 품질 측정)

  • Jung, Hye-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.45-50
    • /
    • 2019
  • This study proposes a method to measure software reliability according to software reliability measurement model to measure software reliability. The model presented in this study uses the distribution of Non - Homogeneous Poisson Process and presents a measure of the software reliability of the presented model. As a method to select a suitable software reliability growth model according to the presented model, we have studied a method of proposing an appropriate software reliability function by calculating the mean square error according to the estimated value of the reliability function according to the software failure data. In this study, we propose a reliability function to measure the software quality and suggest a method to select the software reliability function from the viewpoint of minimizing the error of the estimation value by applying the failure data.

The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology (종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Kang, Young-Sig
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

Method of Displaying Time Series Analysis Results on a Three-Dimensional Surface (3차원 표면에서의 시계열 분석결과 표출방법)

  • Bong-Jun LEE;Cheol-Hee PARK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • A lot of the data currently measured is measured based on indicators, but since the height value of the measurement point is not used as basic data, difficulties arise when trying to use it in a three-dimensional geographic information system. Various methods can be used to create polygons by drawing points on the surface using topographic information or extracting the height value of each measurement point on the surface in order to display large quantities on the surface. Among the various types of data expression methods, this study attempts a data construction and display method to improve visualization performance of time series measurement data expressed on the surface, and examines its procedures and strengths and weaknesses.

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.