The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology

종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안

  • Kweon, Dae-Cheol (Department of Radiological Science, Shinhan University) ;
  • Yang, Sung-Hwan (Department of Prosthetics & Orthotics, Korea National University of Welfare) ;
  • Kang, Young-Sig (Department of Occupational Health & Safety Engineering, Semyung University)
  • 권대철 (신한대학교 방사선학과) ;
  • 양성환 (한국복지대학교 의료보장구과) ;
  • 강영식 (세명대학교 보건안전공학과)
  • Received : 2018.11.29
  • Accepted : 2018.12.21
  • Published : 2018.12.31

Abstract

Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

Keywords

References

  1. Choi, S. G., "A Simulation Study on the Airborne Virus Transmission in a Hospital Depending on the HAVC System", Journal of the Korean Institute of Plant Engineering, 21(3), pp. 107-115, 2016.
  2. Choi, Y. J. and Kweon, D. C., "Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta", Journal of the Korean Magnetic Society, 26(4), pp. 142-148, 2016. https://doi.org/10.4283/JKMS.2016.26.4.142
  3. Im, I. C., Lee, H. Y. and An, H., "A Study on the Illumination Environment of Ultrasound Examination Room", Journal of the Korean Society of Radiology, 11(4), pp. 212-219, 2017.
  4. Lee, J. E. and Choi, A. S., "A Study of Luminous Environment for Standard Illuminance in Residential Areas", Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 19(3), pp. 1-9, 2005.
  5. Kim, D. B., "A Study on the Operation of Emergency Room Considering Factors of Medical Error", Journal of the Korean Institute of Plant Engineering, 23(1), pp. 49-58, 2018.
  6. Kim, J. M., Han, A. Y., Lee, H. Y., Lee, S. R. and Kweon D. C., "Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe", Journal of the Korean Magnetics Society, 26(5), pp. 1-5, 2016. https://doi.org/10.4283/JKMS.2016.26.1.001
  7. Kim, S. R., Park, S. Y., Yeo, H. J., Kim. D. Y., Jeong, J. H., Jang H. S., Shin, J. C. and Park, M. J., "The Change of Convergence Function of Convergence Insufficiency in Their Twenties after Doing Near Work Using a Smart phone", Journal of Korean Ophthalmic Optics Society, 23(1), pp. 47-56, 2018. https://doi.org/10.14479/jkoos.2018.23.1.47
  8. Mettler, Jr F. A., Wiest, P. W., Locken, J. A. and Kelsey, C. A., "CT Scanning: Patterns of Use and Dose", Journal of Radiological Protection, 20(4), pp. 353-359, 2000. https://doi.org/10.1088/0952-4746/20/4/301
  9. Moo, S. Y. and Lee, H. S., "A Comparative Analysis of Actual Measurement and Simulation of Illumination in Senior Hospitals-Focused on Four Patient Hospital Rooms at K Senior Hospital", Proceeding of Journal of the Korean Institute of Interior Design, pp. 130-134, 2015.
  10. Moo, S. Y. and Lee, H. S., "Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals", Journal of the Korean Institute of Interior Design, 24(2), pp. 189-196, 2015.
  11. Oh, C. O., "Nurses' Evaluation of Characteristics of Interior Space in Outpatient Department of General Hospital", Journal of the Korean Institute of Interior Design, 23(3), pp. 64-74, 2014. https://doi.org/10.14774/JKIID.2014.23.3.064
  12. Park, M. Y. and Jung, S. E., "CT Radiation Dose and Radiation Reduction Strategies", Journal of Korean Medical Association, 54(12), pp. 1262-1268, 2011. https://doi.org/10.5124/jkma.2011.54.12.1262
  13. Periyasamy, M. and Dhanasekaran, R., "Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography scan", Journal of Magnetics, 20(3), pp. 295-301, 2015. https://doi.org/10.4283/JMAG.2015.20.3.295
  14. Ruess, L. O'Connor, S. C. Cho, K. H. Hussain, F. H. Howard, W. J. 3rd. Slaughter, R. C. and Hedge, A., "Carpal Tunnel Syndrome and Cubital Tunnel Syndrome: Work-related Musculoskeletal Disorders in Four Symptomatic Radiologists", American Journal of Roentgenology, 181(1), pp. 37-42, 2003. https://doi.org/10.2214/ajr.181.1.1810037
  15. Yoo, M. J., Hong, S. K. and Choi, A. S., "A Preliminary Study on the Lighting Design of Hospitals for LED Lighting Application", Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 25(12), pp. 1-10, 2011.
  16. Yoo, M. Y., Park, S., Jang, H. J. and Kweon, D. C., "Comparison of Image Quality and Dose According to the Arm Positioning in the Chest CT", Journal of the Korean Society of Radiology, 8(2), pp. 75-79, 2014. https://doi.org/10.7742/jksr.2014.8.2.75