• Title/Summary/Keyword: Vacuum pump

Search Result 362, Processing Time 0.029 seconds

Removal of a Heavy Metal from Wastewater using Membrane Process and Instrumental Analysis (Membrane 공정을 이용한 폐수로부터 중금속의 제거 및 기기분석)

  • Park, Kyung-Ai;Lee, Seung-Bum;Kim, Hyung-Jin;Hong, In-Kwon
    • Elastomers and Composites
    • /
    • v.30 no.3
    • /
    • pp.229-234
    • /
    • 1995
  • Membrane process has been applied widely to petroleum chemistry, fine chemistry, polymer, electronics, food, bioprocessing, and wastewater treatment process. Membrane process has advantage that there's no phase change through separation, energy consumption is smaller than other separation processes. And equipment investment and operation cost are inxpensive too. We prepared the silicone rubber membrane and then separated the heavy metal ion from wastewater. Silicone rubber membrane was prepared using a superitical fluid process and heavy metal ions were separated from the chromium nitrate, ferric sulfate, cupric sulfate, nickel sulfate aqueous solution. The pressure difference between top and bottom of separation apparatus was preserved by vacuum pump, and the removal amount of heavy metal at each separation step were analyzed by instrumental analysis, AAS. The surface and pore of silicone rubber membrane was investigated using SEM, and the capability of wastewater treatment using a silicone rubber membrane was proposed as calculated removal rate of heavy metal after comparing removal amount of heavy metal to amount of heavy metal in mother solution by AAS analysis.

  • PDF

Measurement of The Thermal Contact Conductance in Nuclear Fuel Element (핵 연료 요소내의 접촉 열전도도 측정)

  • Sung-Deok Hong;;Goon-Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-81
    • /
    • 1990
  • Experiments to predict the thermal contact conductance between the fuel pellet and cladding have been performed, which is important to determine the temperature distibution within the fuel rod. UO$_2$and Zircaloy-2 are used in these experiments. The measuring apparatus is composed of a presser which controls the contact pressure, a thermometer with 5.5 sheathed thermocouples, a vacuum pump, pellet and cladding rods, and two heating devices, etc. The thermal contact conductances were measured with varying the contact pressure and surface roughnesses of UO$_2$and Zircaloy-2 bars. The results show that an increase in the contact pressure and a decrease of surface roughness resulted in increase of the thermal contact conductance. Finally, a fitting correlation has been established and compared with widely-used correlations.

  • PDF

Automatic Unloading System for Modernizing the Busan Cooperative Fish Market (부산공동어시장 현대화를 위한 양륙자동화설비 구축 방안에 관한 연구)

  • Lee, Kyung-Chang;Jung, Young-Seok;Kwak, Sung-Woo;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.88-94
    • /
    • 2021
  • Currently, the Busan cooperative fish market follows a traditional market style. This study first investigates the current conditions and environment of the market, and to modernize the market, it proposes a new automatic unloading system based on the benchmark of Namhae Suhyup. In this system, a Korean-type suction fish vacuum pump is employed to increase the loading time. An automatic grader with an adjusting device for inclined angles and a weighing machine with an automatic alignment device are proposed. In addition, a folding machine is employed to prepare boxes. The specifications for each subsystem are provided. By implementing this system, the freshness of fish can be maintained and the sellers can earn more. This system can also be applied to the cooling system of the fish reservoir of littoral sea fishing boats.

Dry Etching of GaAs and AlGaAs in Diffuion Pump-Based Capacitively Coupled BCl3 Plasmas (확산펌프 기반의 BCl3 축전결합 플라즈마를 이용한 GaAs와 AlGaAs의 건식 식각)

  • Lee, S.H.;Park, J.H.;Noh, H.S.;Choi, K.H.;Song, H.J.;Cho, G.S.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.288-295
    • /
    • 2009
  • We report the etch characteristics of GaAs and AlGaAs in the diffusion pump-based capacitively coupled $BCl_3$ plasma. Process variables were chamber pressure ($50{\sim}180$ mTorr), CCP power ($50{\sim}200\;W$) and $BCl_3$ gas flow rate ($2.5{\sim}10$ sccm). Surface profilometry was used for etch rate and surface roughness measurement after etching. Scanning electron microscopy was used to analyze the etched sidewall and surface morphology. Optical emission spectroscopy was used in order to characterize the emission peaks of the $BCl_3$ plasma during etching. We have achieved $0.25{\mu}m$/min of GaAs etch rate with only 5 sccm $BCl_3$ flow rate when the chamber pressure was in the range of 50{\sim}130 mTorr. The etch rates of AlGaAs were a little lower than those of GaAs at the conditions. However, the etch rates of GaAs and AlGaAs decreased significantly when the chamber pressure increased to 180 mTorr. GaAs and AlGaAs were not etched with 50 W CCP power. With $100{\sim}200\;W$ CCP power, etch rates of the materials increased over $0.3{\mu}m$/min. It was found that the etch rates of GaAs and AlGaAs were not always proportional to the increase of CCP power. We also found the interesting result that AlGaAs did not etched at 2.5 sccm $BCl_3$ flow rate at 75 mTorr and 100 W CCP power even though it was etched fast like GaAs with more $BCl_3$ gas flow rates. By contrast, GaAs was etched at ${{\sim}}0.3{\mu}m$/min at the 2.5 sccm $BCl_3$ flow rate condition. A broad molecular peak was noticed in the range of $500{\sim}700\;mm$ wavelength during the $BCl_3$ plasma etching. SEM photos showed that 10 sccm $BCl_3$ plama produced more undercutting on GaAs sidewall than 5 sccm $BCl_3$ plasma.

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Structural Analysis of a Suction Pad for a Removable Bike Carrier using Computational and Experimental Methods (탈착식 자전거 캐리어용 흡착 패드의 실험 및 전산적 방법을 활용한 구조해석)

  • Suh, Yeong Sung;Lim, Geun Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.622-628
    • /
    • 2016
  • As the suction pad-supporting bike carrier attached to a car may be subject to an excessive dynamic load due to random vibrations and centrifugal forces during driving, its structural safety is of great concern. To examine this, the finite-element method with a fluid-structure interaction should be used because the pressure on the pad bottom is changed in real time according to the fluctuations of the force or the moment applied on the pad. This method, however, has high computing costs in terms of modeling efforts and software expense. Moreover, the accuracy of computation is not easily guaranteed. Therefore, a new method combining the experiment and computation is proposed in this paper: the bottom pressure and contact area of the pad under varying loads was measured in real time and the acquired data are then used in the nonlinear elastic finite-element calculations. The computational and experimental results obtained with the product under development showed that the safety margin of the pad under the axial loading is relatively sufficient, whereas with an excessive rotational loading, the pad is vulnerable to separation or a local surface damage; hence, the safety margin may not be secured. The predicted contact behavior under the variation of the magnitude and type of the loading were in good agreement with the one from the experiment. The proposed analysis method in this study could be used in the design of similar vacuum pad systems.

Antibacterial Activity of $NANOVER^{TM}$ Against Oral Malodor Generating Microorganisms 1. The Effect of Nanosilver on Growth of Oral Malodor Generating Microorganisms (구취유발세균에 대한 $NANOVER^{TM}$의 항균효과 검사 1. Nanosilver가 구취 세균의 증식에 미치는 영향)

  • Jung, Young-Hee;Mo, Hye-Won;Jeong, Ji-Suk;Choi, Kyung-Ho;Choi, Jae-Kap;Hur, Yun-Kyung;Lee, Sang-Heun
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.39-48
    • /
    • 2009
  • Recently there is much interest in the antibacterial activity of nano-sized silver particle (nanosilver) since silver is known to be safe and effective as disinfectant for a long time. Oral malodor is considered to originate in the oral cavity primarily as a result of production of malodorous compounds by oral bacteria. Major compounds responsible for oral malodor are volatile sulfur compounds, which is thought to be generated by the G(-) anaerobic bacteria found normally in the oral cavity, especially on the dorsum of the tongue. The purposes of this study were to investigate the effect of nanosilver on growth of oral malodor generating microorganisms, including Fusobacterium nucleatum, Prevotella melaninogenica, Klebsiella pneumonia, and to determine the optimal culture condition of them. The results were as follows: 1. The optimal culture condition for P. melaninogenica was vacuum culture using desiccator after evacuation of air by vacuum pump in chopped beef meat media. 2. The growth of K. pneumonia was temporarily inhibited by nanosilver (5 ppm and 10 ppm). 3. The morphological alteration and cell damage caused by nanosilver were observed in K. pneumonia.

A Study of Process factors on the Recycling of Reactive Metal Scraps in Plasma Arc Remelting (Plasma Arc Remelting에서 활성 금속 Scrap 재활용에 미치는 공정인자의 연구)

  • Jung, Jae-Young;Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.3-9
    • /
    • 2017
  • In this study, plasma arc remelting behaviors according to arc current, arc voltage, and types of plasma gas were investigated using Kroll processed Ti sponges as anode. In the discharge pressure range of vacuum pump ($200{\sim}300kgf/cm^2$), the arc voltage did not vary greatly with the increase of discharge pressure at a given arc length. This means that the pressure in the vacuum chamber during operation hardly changes and the atmospheric pressure maintains. Under various conditions of arc currents (700~900A), the arc voltage slightly increased with arc current. The effects of anode materials and operational variables on the arc length-arc voltage relationship were compared with the results in previous studies. When the atmospheric gas changed from argon to helium, double effect of improvement on the output of the steady state was observed. The increase of output in the plasma arc device was accompanied by an increase in the melting rate of the Ti sponge and the quality of the ingot surface was also improved. The plasma arc remelting of the new scrap titanium and the old scrap zirconium alloy could result in the fabrication of an ingot with high surface quality.

Integrated RT-PCR Microdevice with an Immunochromatographic Strip for Colorimetric Influenza H1N1 virus detection

  • Heo, Hyun Young;Kim, Yong Tae;Chen, Yuchao;Choi, Jong Young;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.273-273
    • /
    • 2013
  • Recently, Point-of-care (POC) testing microdevices enable to do the patient monitoring, drug screening, pathogen detection in the outside of hospital. Immunochromatographic strip (ICS) is one of the diagnostic technologies which are widely applied to POC detection. Relatively low cost, simplicity to use, easy interpretations of the diagnostic results and high stability under any circumstances are representative advantages of POC diagnosis. It would provide colorimetric results more conveniently, if the genetic analysis microsystem incorporates the ICS as a detector part. In this work, we develop a reverse transcriptase-polymerase chain reaction (RT-PCR) microfluidic device integrated with a ROSGENE strip for colorimetric influenza H1N1 virus detection. The integrated RT-PCR- ROSGENE device is consist of four functional units which are a pneumatic micropump for sample loading, 2 ${\mu}L$ volume RT-PCR chamber for target gene amplification, a resistance temperature detector (RTD) electrode for temperature control, and a ROSGENE strip for target gene detection. The device was fabricated by combining four layers: First wafer is for RTD microfabrication, the second wafer is for PCR chamber at the bottom and micropump channel on the top, the third is the monolithic PDMS, and the fourth is the manifold for micropump operation. The RT-PCR was performed with subtype specific forward and reverse primers which were labeled with Texas-red, serving as a fluorescent hapten. A biotin-dUTP was used to insert biotin moieties in the PCR amplicons, during the RT-PCR. The RT-PCR amplicons were loaded in the sample application area, and they were conjugated with Au NP-labeled hapten-antibody. The test band embedded with streptavidins captures the biotin labeled amplicons and we can see violet colorimetric signals if the target gene was amplified with the control line. The off-chip RT-PCR amplicons of the influenza H1N1 virus were analyzed with a ROSGENE strip in comparison with an agarose gel electrophoresis. The intensities of test line was proportional to the template quantity and the detection sensitivity of the strip was better than that of the agarose gel. The test band of the ROSGENE strip could be observed with only 10 copies of a RNA template by the naked eyes. For the on-chip RT-PCR-ROSGENE experiments, a RT-PCR cocktail was injected into the chamber from the inlet reservoir to the waste outlet by the micro-pump actuation. After filling without bubbles inside the chamber, a RT-PCR thermal cycling was executed for 2 hours with all the microvalves closed to isolate the PCR chamber. After thermal cycling, the RT-PCR product was delivered to the attached ROSGENE strip through the outlet reservoir. After dropping 40 ${\mu}L$ of an eluant buffer at the end of the strip, the violet test line was detected as a H1N1 virus indicator, while the negative experiment only revealed a control line and while the positive experiment a control and a test line was appeared.

  • PDF