Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer

국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선

  • Park, Jun-Hyung (Cyclotron Research Center, Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
  • Im, Ki-Seop (SamYoung Unitech Ltd.) ;
  • Lee, Hong-Jin (Cyclotron Research Center, Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
  • Jeong, Kyung-Il (SamYoung Unitech Ltd.) ;
  • Lee, Byung-Chul (Cyclotron Research Center, Department of Nuclear Medicine, Seoul National University Bundang Hospital) ;
  • Lee, In-Won (Cyclotron Research Center, Department of Nuclear Medicine, Seoul National University Bundang Hospital)
  • 박준형 (분당 서울대학교병원 핵의학과) ;
  • 임기섭 ((주)삼영유니텍) ;
  • 이홍진 (분당 서울대학교병원 핵의학과) ;
  • 정경일 ((주)삼영유니텍) ;
  • 이병철 (분당 서울대학교병원 핵의학과) ;
  • 이인원 (분당 서울대학교병원 핵의학과)
  • Received : 2009.08.10
  • Accepted : 2009.09.08
  • Published : 2009.10.10

Abstract

Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

Keywords