A Study on Radiographic Equipments and Situation for the Chest (흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査))

  • Ko, Shin-Gwan;An, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

Poly(4-vinylpyridine)/Vinyl Acetate-Vinyl Alcohol Copolymer Blends : 9. Phase. Behavior (폴리(4-비닐피리딘)/비닐아세테이트-비닐알코올 공중합체 블렌드 :2. 상 거동)

  • Lee, Joon-Youl;Choi, Dong-Hoon;Lee, Hyeok
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.649-656
    • /
    • 2001
  • Miscibility of poly(4-vinylpyridine) (P4VP) blends with poly(vinyl acetate-co-vinyl alcohol) (VAc-VAL copolymers) was investigated as a function of comonomer composition of VAc-VAL copolymers. Differential scanning calorimetry (DSC) and thermo-optical microscopic (TOM) analysis confirmed that P4VP is miscible with VAc-VAL copolymers containing more than 30 mole% VAL. Fourier transform inflated (FT-IR) spectroscopic analysis revealed that the strong intermolecular hydrongen bonding interaction between the vinylpyridine and VAL hydroxyl group was formed. Theoretical phase diagram was constructed by the calculation using the Association model, a thermodynamic model for hydrogen-bonded polymer blend systems developed by Coleman et al. The calculated theoretical binodal phase diagrams were in good agreement with the experimentally determined cloud point curves.

  • PDF

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT) (심장 CT 검사시 ASIR 적용에 따른 선량 평가)

  • Jang, Hyun-Cheol;Kim, Hyun-Ju;Cho, Jae-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.252-259
    • /
    • 2011
  • To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.

A New Equation for the Compressive Strength. of Existing Concrete Structures by Ultrasonic Pulse Velocity Test (초음파 시험법에 의한 실존 콘크리트 구조체의 압축강도 제안식에 관한 연구)

  • 권영웅;신정식;유재은;이성용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.757-762
    • /
    • 2003
  • This paper concerns the new equations for the compressive strength of existing concrete structures by ultrasonic pulse velocity test. The proposed equation are as follows; fc =5255.9 - 3365.8Vp + $548.4Vp^2$ (here, $r^2$=89.7%)

  • PDF

Selective Chemical Wet Etching of Si0.8Ge0.2/Si Multilayer

  • Kil, Yeon-Ho;Yang, Jong-Han;Kang, Sukil;Jeong, Tae Soo;Kim, Taek Sung;Shim, Kyu-Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.668-675
    • /
    • 2013
  • We investigate the effect of the ageing time and etching time on the etching rate of SiGe mixed etching solution, namely 1 vp HF (6%), 2 vp $H_2O_2$ (30%) and 3 vp $CH_3COOH$ (99.8%). For this etching solution, we found that the etch rate of SiGe layer is saturated after the ageing time of 72 hours, and the selectivity of $Si_{0.8}Ge_{0.2}$ layer and Si layer is 20:1 at ageing time of 72 hours. The collapse was appeared at the etching time of 9min with etching solution of after saturation ageing time.

Usefulness of Application of Tube Voltage Changes to Reduce Patient Dose during Abdominal CT Follow up (반복적인 복부 컴퓨터단층촬영 시행 시 환자선량 감소를 위한 관전압 변화 적용의 유용성)

  • Yoon, Joon;Kim, HyeonJu
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.293-299
    • /
    • 2021
  • In order to reduce the irresistible radiation exposure of patients who perform periodic examinations using a CT among various scan parameters a method to reduce patient dose was investigated through changes in the tube voltage close to X-ray penetrating power. As a result of the experiment 100 kVp was applied instead of 120 kVp which is commonly used in clinical practice and CTDI decreased by about 41% during scan. In addition the degree of change in image quality was measured as 1046.1±3.7 HU for CT value and 71.4±7.9 for Pixel value and statistical analysis showed no significant difference (0.05

Quantitative and Qualitative Evaluation according to Radiation Dose Conditions when using MAR function in Implant examination from Cone Beam CT (ConeBeam CT로 임플란트 검사 시 MAR 기능 유무와 선량조건에 따른 정량적 및 정성적 평가)

  • Hyun-Jun, Ahn;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.905-917
    • /
    • 2022
  • This study was conducted to evaluate the use of the MAR function and the image quality of the image when examining with each radiation dose. A simple Periapical phantom was made to set up an implant, and images were obtained and analyzed according to the presence or absence of MAR function for each radiation dose using CBCT equipment. In this study, MEAN, SNR, and CNR values were obtained using the Image J program, and through statistical analysis, images were the most quantitative and suitable values when the Abutment of Implant was 100 kVp and 8 mA, and when the Center of Implant and Apex of Implant were 100 kVp and 9 mA. As a result, it was confirmed that if the radiation dose increased, the Pixel Value, SNR, and CNR values of the image rose up so that the quality of the image improved, and using the MAR function reduced artifacts.

Experimental Infection for the Neutralization of White Spot Syndrome Virus (WSSV) in Wild Captured Sand Shrimp, Crangon affinis (자연산 자주새우(Crangon affinis)에서 흰반점바이러스(WSSV)의 neutralization을 위한 인위감염(experimental infection))

  • Gong, Soo-Jung;Kim, Yeong-Jin;Choi, Mi-Ran;Kim, Sung-Koo
    • Journal of Life Science
    • /
    • v.20 no.9
    • /
    • pp.1294-1298
    • /
    • 2010
  • White spot syndrome virus (WSSV) is one of the most virulent viral agents threatening the penaeid shrimp culture industry. This study was carried out to evaluate the susceptibility of the sand shrimp, Crangon affinis, to WSSV as an alternative experimental model. WSSV caused 100% mortality in C. affinis within 7 days after experimental infection by immersion. Based on challenge studies, it was confirmed that C. affinis could be a potential host in WSSV transmission. Also, the neutralization of WSSV was carried out using an antiserum raised against recombinant envelop protein rVP466 to evaluate the WSSV infection mechanism. A constant amount of WSSV (at $1{\times}10^4$ diluted stocks) was incubated with various amounts of antiserum and then mixed to 20 l reservoir for the immersion challenge of C. affinis for neutralization. At 5 days post challenge, the shrimp in the positive control immersed in the immersion reservoir containing WSSV stock showed 100% mortality. The shrimps challenged with the 3 different mixtures of WSSV and rVP466 antiserum (1:0.1, 1:0.5 and 1:1) showed 100%, 68.8% and 68.8% mortality at 14 days post challenge, respectively. These results indicated that the antiserum raised against rVP466 could block WSSV infection in C. affinis. Therefore, this study confirmed that C. affinis can be naturally infected by WSSV as another potential host and that C. affinis can be used as an alternative experimental animal instead of penaeid shrimps.

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

A Study on the Detection Ability of Minute Lesions in X-ray Using the Molybdenum Target (Molybdenum 저지극을 이용한 X-ray의 미세병소 검출능력에 관한 연구)

  • Yang, Da-Rae;Dong, Kyung-Rae;Park, Yong-Soon;Ji, Youn-Sang;Kim, Young-Keun;Kim, Chang-Bok
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Beam quality is determined according to Xray tube's target material. In a range of between 22 kVp and 28 kVp, molybdenum target generates the characteristics energy between the average 17.9 kVp and 19.5 kVp, which produces the high contrast image of the breast. In this study, we used the Mo/Mo combination breast device and ALVIM TRM phantom and measured the detection ability of the minute lesion in the breast imaging throughout analyzing ROC curves. Assuming that an average subject thickness of the breast is 40 mm, the detection ability was not dependent on the kVp changes in a while dependent on both the mAs and thickness change. We can assure that it is not needed to increase the kVp for the imaging of breast which thickness is within the mean range of 40 mm.