Browse > Article
http://dx.doi.org/10.5392/JKCA.2011.11.5.252

Radiation dose Assesment according to the Adaptive Statistical Iterative Reconstruction Technique of Cardiac Computed Tomography(CT)  

Jang, Hyun-Cheol (순천향대학교 부천병원 영상의학과)
Kim, Hyun-Ju (순천향대학교 부천병원 영상의학과)
Cho, Jae-Hwan (경산1대학 방사선과)
Publication Information
Abstract
To identify the effects of the application of the adaptive statistical iterative reconstruction (ASIR) technique in combination with the other two factors of body mass Index (BMI) and tube potential on radiation dose in cardiac CT. The patient receiving operation the cardiac CT examination was divided four groups into according to kVp.[A group(n=20), Non-ASIR, BMI < 25, 100 kVp; B group(n=20), Non-ASIR, BMI > 25, 120 kVp; C group(n=20), 40% ASIR BMI < 25, 100 kVp; D group(n=20), 40% ASIR, BMI > 25, 120 kVp] After setting up the region of interest in the main artery central part and right coronary artery and left anterior descending artery, the CT number was measured and an average and standard deviation were analyzed. There were A group and the difference which the image noise notes statistically between C. And A group was high so that the noise could note than C group (group A, 494 ${\pm}$ 32 HU; group C, 482 ${\pm}$ 48 HU: P<0.05) In addition, there were B group and the difference noted statistically between D. And B group was high so that the noise could note than D group (group B, 510 ${\pm}$ 45 HU; group D, 480 ${\pm}$ 82 HU: P<0.05). In the qualitative analysis of an image, there was no difference (p>0.05) which a group, B group, C group, and D as to average, A group 4.13${\pm}$0.2, B group 4.18${\pm}$0.1, and C group 4.1${\pm}$0.2 and D group note statistically altogether with 4.15${\pm}$0.1 as a result of making the clinical evaluation according to the coronary artery segments. And the inappropriate image was shown to the diagnosis in all groups. As to the radiation dose, a group 8.6${\pm}$0.9 and B group 14.9${\pm}$0.4 and C group 5.8${\pm}$0.5 and D group are 10.1${\pm}$0.6 mSv.
Keywords
ASIR; BMI; Radiation dose; Image Noise;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Z. Szucs-Farkas, L. Kurmann, and T. Strautz, "Patient exposure and image quality of low-dose pulmonary computed tomography angiography, comparison of 100 kVp and 80 kVp protocols," Invest Radiol. Vol.43, No.4, pp.871-876, 2008.   DOI   ScienceOn
2 K. Sauer and C. bouman, "A local update strategy for iterative reconstruction from projections," IEEE Trans, on Signal Processing 41, 1993(2).   DOI   ScienceOn
3 Alvin C. Silva, Holly J. Lawder, and Amy Hara, "Innovation in CT Dose Reduction Strategy, Application of the Adaptive Statistical Iterative Reconstruction Algorithm," AJR. Vol.194, No.1, pp.191-199, 2010.   DOI   ScienceOn
4 F. A. Mettler, J. A. Briggs, and R. Carchman, "Use of radiology in U.S general short-term hospital:1980-1990," Radiology. Vol.189, No.3, pp.377-380, 1993.   DOI
5 J. David and Brenner, Eric J. "Computed Tomography-An Increasing Source of Radiation Exposure," N Engl J Med. Vol.357, No.1, pp.2277-2284, 2007.   DOI   ScienceOn
6 Fuminari Tatsugami, Lars Husmann, and Bernhard A. herzog, "Evaluation of a Body Mass Index-Adapted Protocol for Low-Dose 64-MDCT Coronary Angiography with Prospective ECG Triggering," AM J Roentgenol. Vol.192, No.2, pp.635-638, 2009.   DOI   ScienceOn
7 김윤경, 김유경, "체질량 지수 및 관전압 변화에 따른 CT 관상동맥 조영술의 영상의 질 및 방사선 피폭량 비교", 대한영상의학회지, 제62권, 제1호, pp.29-35, 2010.   과학기술학회마을
8 A. K. Hara, R. G. Paden, and A. C. Silva, "Iterative reconstruction technique for reducing body radiation dose at CT, feasibility study," AJR, Vol193, No.2, pp.764-771, 2009.   DOI   ScienceOn
9 A. B. Smith, W. P. Dillon, and B. C. Lau, "Radiation dose reduction strategy for CT protocols, successful implementation in neuroradiology section," Radiology. Vol.247, No.3, pp.499-506, 2008.   DOI   ScienceOn
10 J Anthony Seibert, Gray T barnes, and Robert G Gould, "Specification, Acceptance testing and quality control of diagnostic X-ray imaging equipment," Medical physics monograph. Vol.20, No.1, pp.899-936, 1991.
11 K. T. Bae, B. A. Seeck, and C. F. Hildebolt, "Contrast enhancement in cardiovascular MDCT, effect of body weight, height, body surface area, body mass index, and obesity," Am J Roentgenol Vol.190, No.4, pp.777-784, 2008.   DOI   ScienceOn
12 S. Leschka, P. Stolzmann, and F. T. Schmid, "Low kilovoltage cardiac dual-source CT, attenuation, noise, and radiation dose," Eur Radiol. Vol.18, No.4, pp.1809-1817, 2008.   DOI
13 R. E. Bunge and C. Herman, "Usage of diagnostic procedures: a nationwide hospital study," Radiology. Vol.163, No.2, pp.569-657, 1987.   DOI