• Title/Summary/Keyword: VOCs, HCHO

Search Result 72, Processing Time 0.024 seconds

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

Characteristics of pollutant emission from wallpapers - Around TVOC and HCHO - (벽지에서 발생되는 오염물질 방출특성 - TVOC와 HCHO를 중심으로 -)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.542-551
    • /
    • 2005
  • This study is to investigate the characteristics of emission concentration according to wallpaper sort and emission time using small chamber method. The target compounds included 45 VOCs and formaldehyde, which were respectively determined by adsorption sampling and thermal desorption coupled with GC/MS method, and by sampling in DNPH cartridge and HPLC method. The emission factor of TVOC and HCHO was detected to $1.1mg/m^2{\cdot}h$ and $0.01mg/m^2{\cdot}h$ respectively, and the wallpapers of 25 satisfied emission standard. TVOC emission factor appeared in order of the concentration of PVC, natural, and Non-PVC wallpaper, while HCHO was detected very low concentration without relation to wallpaper sort. The paraffin hydrocarbons appeared to be the most contributable class of hydrocarbons in terms of their concentrations, followed by aromatics, and olefins, halogenated hydrocarbons was not detected. PVC wallpapers plentifully emitted TVOC above other wallpapers, and toluene was showed higher concentration of 10 times than natural wallpaper. In addition to, emission factor according to elapse was gradually decreased.

Improvement of the Architectural Environment by Applying Photocatalyst Building Materials and Ventilation Systems (광촉매 건축자재와 환기시스템 적용에 따른 건축 환경 개선 방안)

  • Yong Woo Song;Seong Eun Kim;Se Hyeon Lim;Sung Jin Sim
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.103-110
    • /
    • 2023
  • People who spend most of their day indoors are continuously exposed to internally and externally generated indoor pollutants. According to a 2022 report from the World Health Organization (WHO), air pollution is the cause of more than 7 million deaths annually worldwide, emphasizing the seriousness of indoor air pollutants. Air pollutants include nitrogen oxides (NOx), formaldehyde (HCHO), and volatile organic compounds (VOCs), which have serious effects on the human body. Photocatalyst is a material that can remove these indoor air pollutants. Photocatalysts not only have the ability to remove dust precursors, but also have antibacterial, sterilizing, and deodorizing functions, making them effective in improving indoor air quality. This study suggests areas and methods in which photocatalysts can be applied to buildings. Fields of application include interior and exterior construction materials such as concrete, as well as organic paints and ventilation devices. If appropriate utilization plans are developed, it may be possible to improve the built environment through reduced indoor and outdoor pollutant levels.

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

The Effect on Indoor Air Quality Improvement by Ventilation Rate in Newly Built Apartment (환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토)

  • Choi Seok-Yong;Kim Sang-Hee;Yee Jung-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.649-655
    • /
    • 2006
  • The recent indoor air quality problem in a newly-built apartment house is resulted from the improvement of airtightness performance and the use of the building material contained harmful chemical substances. As a result, these cause indoor air quality gradually to become worse and the harmful effect on occupant health called Sick House Syndrome. The most effective solution to improve the indoor air quality is to encourage the use of green building material. However, if the house is built with general building material, ventilation with outdoor air is alternative to dilute the pollutant concentration. The purpose of this re-search is to find optimum ventilation time in a newly-built apartment house at which the ventilatoris installed. It is found that the HCHO and toluene concentrations are remarkably decreased with the elapse of ventilation time and the concentration reduction rate is increased with increment of air change rate after one hour after operating the ventilator.

Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality (실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가)

  • Na, Kyung-Ho;Son, Jin-Seok;Sung, Kijune;Jang, Young-Kee
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

A Study on the Field Evaluation about the Indoor Air Quality of Schools Newly Built in Changwon (창원지역 신축학교의 실내공기질 현장평가 연구)

  • Yoo, Jong-Hoon;Kang, Eun-Hye;Son, Young-Hwan;Ha, Suk-Yong;Choi, Jeong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1244-1249
    • /
    • 2006
  • Because students are spending more time in their classroom for learning and study, indoor air quality problems in school classrooms are very important. when the classroom is built for the first time, namely newly built school, the selection of inside finishing material is directly connected with indoor air quality problems especially with HCHO and TVOC. But until now, there is no plenty of study about this. Moreover, there are some concerns about the desks and chairs which are used in classroom will affect the air quality. but almost no study is being made at all Therefore, this study focuses on the field survey and analysis of classroom indoor air quality in newly built schools in Changwon. In this study filed surveys and analysis are conducted as follows. 1) The effect of the material difference in general classroom. 2) The effect of the material and loading ratio difference in special classroom. 3) The effect of the desks and chairs in general classroom.

  • PDF

Concentrations of VOCs and Formaldehyde in Newly Constructed Apartment Buildings Before and After Residence (신축공동주택의 입주전후 VOCs 및 HCHO 농도)

  • Park, Sang-Eun;Kim, Hyun-Wook;Sim, Sang-Hyo;Lee, Se-Hoon;Koo, Jung-Wan
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.98-103
    • /
    • 2007
  • This study was performed to measure the changed concentrations of formaldehyde and volatile organic compounds after moving in the newly constructed apartment buildings at Seoul. From December 2004 to October 2005, we measured the concentration of formaldehyde and volatile organic compounds in newly constructed apartment buildings before and after residence. In conclusion, it showed that there was a significant relationship association between the con centration of the volatile organic compound and the formaldehyde and remodeling of the house, built in-furniture, and ventilation of the house. Therefore, it was suggested that we need preventive measures and management plans about various factors such. as remodeling, and built in-furniture, ventilation to decrease the concentrations of volatile organic compounds and formaldehyde.

The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots (실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과)

  • Park, Jeong-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

Study on the Air Quality of Metropolitan Subway Stations (수도권 지하철 지하역사의 실내공기질 연구)

  • Cho Young-Min;Park Duckshin;Park Byung-Hyun;Park Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.77-82
    • /
    • 2005
  • Recently, people's rising interests toward a 'well-being' lifestyle together with research contributions are accelerating the concerns regarding indoor air pollution making indoor air quality management an emerging environmental challenge of the era. The Ministry of Environment began to regulate the air quality of railway stations last year. The newly established 'Indoor Air Quality Act' covers 17 facilities whereas only underground subway stations and underground markets were regulated by previous 'Underground Air Quality Management Act' of 1996. In this study, we carried out the measurement of temperature, relative humidity, CO(carbon monooxide), $CO_2$(carbon dioxide), HCHO(formaldehyde), PM-10(particulate matters), and VOCs(volatile organic compounds) in underground subway stations. Based on the obtained results, we will suggest a way to improve the indoor air quality of the subway stations.

  • PDF