Concentrations of VOCs and Formaldehyde in Newly Constructed Apartment Buildings Before and After Residence  

Park, Sang-Eun (Department of Preventive Medicine, The Catholic University of Korea)
Kim, Hyun-Wook (Department of Preventive Medicine, The Catholic University of Korea)
Sim, Sang-Hyo (Department of Occupational and Environmental Medicine, Hanyang University Medical Center)
Lee, Se-Hoon (Department of Preventive Medicine, The Catholic University of Korea)
Koo, Jung-Wan (Department of Preventive Medicine, The Catholic University of Korea)
Publication Information
Journal of Environmental Health Sciences / v.33, no.2, 2007 , pp. 98-103 More about this Journal
Abstract
This study was performed to measure the changed concentrations of formaldehyde and volatile organic compounds after moving in the newly constructed apartment buildings at Seoul. From December 2004 to October 2005, we measured the concentration of formaldehyde and volatile organic compounds in newly constructed apartment buildings before and after residence. In conclusion, it showed that there was a significant relationship association between the con centration of the volatile organic compound and the formaldehyde and remodeling of the house, built in-furniture, and ventilation of the house. Therefore, it was suggested that we need preventive measures and management plans about various factors such. as remodeling, and built in-furniture, ventilation to decrease the concentrations of volatile organic compounds and formaldehyde.
Keywords
formaldehyde; volatile organic compounds;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Tichenor, B. A., Sparks, L. A., Wihite, J. B. and Jackson, M. D. : Evaluating sources of indoor air pollution. Journal of the Air and Waste Management Association, 40, 487-492, 1990   DOI   ScienceOn
2 Hodgson, A. T., Rodd, A. F., Beal, D. and Chandra, S. : Volatile organic compound concentration and emission rates in new manufactured and site-built houses. Indoor Air, 10, 178-192, 2000   DOI   ScienceOn
3 Alfred, T., Hodgson, Joan M, Daisey : Sources and source strengths of volatile organic compounds in a new office building. Air and Waste Management Association, 41, 1461-1468, 1991   DOI
4 조장제, 구민호, 장정욱, 손승연, 김태오 : 신축아파트에서의 휘발성유기화합물 농도 조사. 한국대기환경학회 춘계학술대회 논문집, 2004
5 이윤규, 김창남 : 기존 공동주택의 실내공기질 실태에 관한 측정 연구. 대한건축학회 논문집, 20(11), 327-334, 2004
6 Ten Brinke, J., Selvin, S., Hodgson, A. T. et al. : Development of new volatile organic compound (VOC) exposure metrics and their relationship to 'sick building syndrome' symptoms. Indoor Air, 8, 140-152, 1998   DOI   ScienceOn
7 이용식 : 신축 아파트내 실내공기오염에 관한 연구. 고려대학교 대학원 석사학위논문, 2004
8 심상효, 김윤신 : 신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로- . 한국환경보건학회지, 32(4), 275-281, 2006   과학기술학회마을
9 김윤신, 이철민, 문정숙, 김상욱 : 서울경기지역 초중고등학교 교실의 실내공기오염에 관한 연구. 한국학교보건학회지, 16(1), 81-90, 2003
10 Tepper, J. S., Moser, V. C., Costa, D. L. and Mason, M. A. : Toxicological and chemical evalution of emission from carpet samples. American Industrial Hygiene Association Journal, 56(2), 158-170, 1995   DOI   ScienceOn
11 Park, J . S. and Ikeda, K. : Variations o f f ormaldehyde and VOC levels during 3 years in new and older homes. Indoor Air, 16, 129-135, 2006   DOI   ScienceOn
12 방정현, 박진철, 이언구 : 실내 마감 페인트에서의 휘발성유기용제 및 포름알데히드의 발생농도 측정연구. 대한건축학회 학술발표대회 논문집, 18(1), 551-558, 1998
13 Jitendra, J. S. and Hanwant, B. S. : Distribution of volatile organic chemicals in outdoor and indoor air. Environmental Science Technol, 22, 1381-1388, 1988   DOI   ScienceOn
14 강동화 : 바닥난방 공간의 베이크 아웃에 의한 VOCs 방출에 관한 연구. 서울대학교 대학원 석사학위논문, 2005
15 손장열, 백용규, 방승기, 이철구, 조 현 : 고층 아파트에서 환기 조건에 따른 실내 VOCs 농도변화에 관한 연구. 대한건축학회 학술발표논문집, 22(1), 533-537, 2002
16 Tobin, R. S., Bourgeau, M., Otson, R. and Wood, G. C. : Residential indoor air quality guidelines. Indoor Environmental, 2, 267-275, 1992
17 Rehwagen, M., Schlink, U. and Herbarth, O. : Seasonal cycle of VOCs in apartments. Indoor Air, 13, 283-291, 2003   DOI   ScienceOn
18 Afshari, A., Lundgren, B. and Ekberg, L. E. : Comparison of three small chamber test methods for the measurement of VOC emission rates from paint. Indoor Air, 13, 156-165, 2003   DOI   ScienceOn
19 국립환경과학원 : 전국 신축공동주택 실내공기질 실태조사. 2004
20 World Health Organization(WHO) : Air quality guidelines-2nd edition. WHO Regional Office for Europe, 2001
21 장지혜 : 새집증후군에 대한 아파트 거주자의 자각증상 및 반응 연구. 연세대학교 대학원 석사학위논문, 2005
22 정유신 : 공동주택의 실내공기환경에 대한 재실자들의 주관적 반응조사에 관한 연구. 동의대학교 대학원 석사학위논문, 2005
23 Wolkoff, P. : Trends in Europe to reduce the indoor air pollution of VOCs. Indoor Air, 13(Suppl. 6), 5-11, 2003   DOI   ScienceOn
24 Wolkoff, P., Clausen, P. A., Nielsen, P. A. and Molhave, L. : The danish twin apartment study; part I: formaldehyde and long-term VOC measurements. Indoor Air, 4, 478-490, 1991
25 서병량, 김신도, 박성규 : 온습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성. 한국환경보건학회지, 32(4), 292-303, 2006   과학기술학회마을
26 하권철 : 경남지역 지하생활공간 중 미량 유해물질인 포름알데히드의 농도 분포 특성. 한국환경보건학회지, 30(5), 353-375, 2004
27 환경부 : 다중이용시설등의 실내공기질 관리법, 2004
28 Martin, A., Cohen, P., Barry, R. and Yukio, Y. : The validation of a passive sampler for indoor and outdoor concentration of volatile organic compounds. Air and Waste Management Association, 40, 993-997, 1990   DOI   ScienceOn
29 Molhave, L. and Krzyzanowski, M. : The right to healthy indoor air: status by 2002. Indoor Air, 13 Suppl 6, 50-53, 2003   DOI   ScienceOn
30 국립환경과학원 : 공동주택 오염도 변화추이 파악을 위한 시계열조사 연구(I). 2006
31 Woods, J. E. : An engineering approach to controlling indoor air quality. Environmental Health Perspectives, 95, 15-21, 1991   DOI