• Title/Summary/Keyword: V-seal

Search Result 34, Processing Time 0.031 seconds

A Study on Structural Safety of the Boom Hoisting Cylinder of a Coal Handling Machine (석탄하역기 붐 호이스팅 실린더의 구조 안전성에 관한 연구)

  • Choi, Yong Hoon;Kwak, Hyo Seo;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1265-1273
    • /
    • 2015
  • A coal handling machine is a type of equipment used for loading coal, the main material in a steam power plant, along a conveyer belt from a ship, and is placed after the driving chain bucket. However, studies on the boom hoisting cylinder, which is a hydraulic system used to control the angle of the boom based on loading location, indicate that domestic models are insufficient, and are thereby often substituted with a foreign product. In this study, a technique for analyzing the contact pressure in a thick-walled cylinder was established by comparing the contact pressure, which is calculated theoretically based on the results obtained from FEM simulation, and by checking whether the working oil is leaking from the boom hoisting cylinder using a v-seal. In addition, the driving motion was simulated according to the strokes of the cylinder, and the structural stability was verified under the maximum output conditions.

Synthesis and Properties of Magnetite for Ferrofluid (자성유체용 마그네타이트의 합성 및 특성)

  • Baek, In-Ho;Jeong, Noh-Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.63-70
    • /
    • 2012
  • Magnetite in the use of magnetic fluid seal was synthesized by coprecipitation method. Mean particle size of magnetite was measured about 12 nm by using dynamic light scattering(DLS). As a result of XRD test, along with the $NH_4OH$ concentration was increased, the crystallinity of magnetite was increased. The zeta potential of dispersed ferrofluid in water was measured in the range from -49.3 mV to -26.2 mV by DLS. The shape of magnetite particle was sphere form, and the spiking effect of aqueous and oily ferrofulid was confirmed.

TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY

  • Veronese, Fabio;Kozlowsk, Tomasz
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.719-726
    • /
    • 2012
  • The object of this work is the validation and assessment of the TRACE v5.0 code using the scaled test ATLAS1 facility in the context of a DVI2 line break. In particular, the experiment selected models the 50%, 6-inch break of a DVI line. The same experiment was also adopted as a reference test in the ISP-503. The ISP-50 was proposed to, and accepted by, the OECD/NEA/CSNI due to its technical importance in the development of a best-estimate of safety analysis methodology for DVI line break accidents. In particular, the behavior of the two-phase flow in the upper annulus downcomer was expected to be complicated. What resulted was the need for relevant models to be implemented into safety analysis codes, in order to predict these thermal hydraulic phenomena correctly.

SURFACE ROUGHNESS AND MICROLEAKAGE OF CLASS V COMPOSITE RESTORATIONS : EFFECT OF SURFACE SEALING (치경부 5급 와동 수복물의 표면 거칠기와 미세누출에 관한 연구 : 표면 전색의 효과)

  • Kim, Min-Jeong;Lee, Mi-Jeong;Yu, Mi-Kyung;Park, Soo-Joung;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.1
    • /
    • pp.22-30
    • /
    • 2005
  • The purpose of this study was to compare the effect of surface sealing materials on microleakage and surface roughness in Class V composite restorations. Twenty five standardized Class V cavity preparations were made on the facial surface of human premolars and were randomly assigned to 5 groups. The teeth were restored with Z-250 after applying Single Bond. Following 7 days storage in distilled water at $37^{\circ}C$, the restorations were sealed as following systems : No sealing ; Single Bond Adhesive ; Biscover ; Fortify ; Optiguard. Then, toothbrush abrasion test was conducted using a wear testing machine. Surface roughness was measured by means of profilometer before and after toothbrushing and the results were statistically analysed by using a paired t-test and ANOVA. The bonded interfaces and the changes of surface roughness were examined by SEM. For microleakage test, specimens were stained in a $2\%$ methylene blue solution, then longitudinally sectioned and analyzed for leakage at occlusal and cervical interfaces using stereomicroscope. The results were statistically analysed by using a Kruskal-Wallis and Mann-Whitney U test. Surface roughness was increasing in all groups after toothbrushing, but no statistically significant differences. In SEM observation, surface sealant was partially retained and partially detached in bonded interfaces. Especially, microgap was identified in cervical margins. In microleakage test, there was better seal in the enamel region and a significant difference between groups at occlusal margin. Control group and Single Bond group had significantly better marginal seal at enamel margin than cervical margin.

Laser Sealing of Dye-Sensitized Solar Cell Panels Using V2O5 and TeO2 Contained Glass (V2O5 및 TeO2 함유 유리를 이용한 염료감응형 태양전지 패널의 레이저 봉착)

  • Cho, Sung Jin;Lee, Kyoung Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.3
    • /
    • pp.170-176
    • /
    • 2014
  • Effective glass frit compositions enabled to absorb laser energy, and to seal a commercial dye-sensitized solar-cell-panel substrate were developed by using $V_2O_5$-based glasses with various amounts of $TeO_2$ substitution. The latter was intended to increase the lifetime of the solar cells. Substitution of $V_2O_5$ by $TeO_2$ provided a strong network structure for the glasses via the formation of tetrahedral pyramids in the glass, and changed the various glass properties, such as glass transition temperature ($T_g$), dilatometric softening point ($T_d$), crystallization temperature, coefficient of thermal expansion (CTE), and glass flowage without any detrimental effect on the laser absorption property of the glasses. The thermal expansion mismatch (${\Delta}{\alpha}$) between the glass frit and the substrate could be controlled within less than ${\pm}5%$ by addition of 10 wt% of ${\beta}$-eucryptite. An 810 nm diode laser was used for the sealing test. The laser sealing test revealed that the VZBT20 glass frit with 10 wt% ${\beta}$-eucryptite was successfully sealed the substrates without interfacial cracks and pores. The optimum sealing conditions were provided by a beam size of 3 mm, laser power of 40 watt, scan speed of 300 mm/s, and 200 irradiation cycles.

Thin and Hermetic Packaging Process for Flat Panel Display Application

  • Kim, Young-Cho;Jeong, Jin-Wook;Lee, Duck-Jung;Choi, Won-Do;Lee, Sang-Geun;Ju, Byeong-Kwon
    • Journal of Information Display
    • /
    • v.3 no.1
    • /
    • pp.11-16
    • /
    • 2002
  • This paper presents a study on the tubeless Plasma Display Panel (PDP) packaging using glass-to-glass electrostatic bonding with intermediate amorphous silicon. The bonded sample sealing the mixed gas with three species showed high strength ranging from 2.5 MPa to 4 MPa. The glass-to-glass bonding for packaging was performed at a low temperature of $180^{\circ}C$ by applying bias of 250 $V_{dc}$ in ambient of mixed gases of He-Ne(27 %)-Xe(3 %). The tubeless packaging was accomplished by bonding the support glass plate of $30mm{\times}50mm$ on the rear glass panel and the capping glass of $20mm{\times}20mm$. The 4-inch color AC-PDP with thickness of 8 mm was successfully fabricated and fully emitted as white color at a firing voltage of 190V.

EFFECT OF SURFACE PENETRATING SEALANT ON THE MICROLEAKAGE OF CERVICAL RESTORATIONS (Surface penetrating sealant가 치경부 수복물의 미세누출에 미치는 영향)

  • 김성원;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.64-76
    • /
    • 2001
  • Despite the improvements in bond strengths of dentin adhesives and resin-modified glass ionomers, the marginal seal of cervical restorations remains a concern. Microleakage at poorly sealed margins can result in staining, post-operative sensitivity, pulpal irritation, and recurrent caries. The objective of this study was to evaluate the effect of surface penetrating sealant(SPS) on the microleakage of cervical restorations. 45 extracted human teeth were selected, and Class V preparations were prepared on the both buccal and lingual surface of the teeth to the following dimensions : 1.5mm axially, 3mm mesiodistally, and 3mm incisogingivally. After cervical restoration with composite resin, compomer, glass ionomer each restoration was treated as three methods: No Tx., Scotchbond Multipurpose Adhesive$^{\circledR}$, Fortify$^{\circledR}$. The sections were examined with a stereomicroscope to determine the extent of microleakage at enamel and dentin margins. The results of this study were as follows. 1. All groups showed some microleakage. 2. Gingival cavity wall with cementum margin showed significantly higher leakage value than occlusal cavity wall with enamel margin. 3. The group treated with SPS showed significantly lower leakage value than no treated group(p<0.05). But there is no difference between Fortify$^{\circledR}$ and Scotchbond Multipurpose adhesive$^{\circledR}$. The results of this study suggest that SPS are effective in reducing microleakage of class V restorations. But it is certain that some microleakage still occurred despite the application of SPS.

  • PDF

Parameter Estimation and Reliability Analysis Using Bayesian Approach for Bolted Joint and O-ring Seal of Solid Rocket Motor (고체 로켓 모터의 체결 볼트와 오링에 대한 베이지안 접근법 기반 모수 추정과 신뢰성 해석)

  • Gang, Jin Hyuk;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1055-1064
    • /
    • 2017
  • Since a device such as a rocket motor requires very high reliability, a reasonable reliability design process is essential. However, Korea has implemented a design method for applying a safety factor to each component. In classic reliability analysis, input variables such as mean and standard deviation, used in the limit state function, are treated as deterministic values. Because the mean and standard deviation are determined by a small amount of data, this approach could lead to inaccurate results. In this study, reliability analysis is performed for bolted joints and o-ring seals, and the Bayesian approach is used to statistically estimate the input variables. The estimated variables and failure probability, calculated by the reliability analysis, are derived in the form of probability distributions.

Additional Study on the Laser Sealing of Dye-Sensitized Solar-Cell-Panels Using V2O5 and TeO2 Containing Glass

  • Cho, Sung-Jin;Lee, Kyoungho
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.103-107
    • /
    • 2015
  • The effective glass frit composition used to absorb laser energy and to seal commercial dye-sensitized solar cell panel substrates has been previously developed using $V_2O_5-TeO_2$-based glass with 10 wt% ${\beta}$-eucryptite as a CTE controlling filler. The optimum sealing conditions are provided using a 3 mm beam, a laser power of 40 watt, a scan speed of 300 mm/s, and 200 irradiation cycles. In this study, the feasibility of the developed glass frit is investigated in terms of the sealing strength and chemical durability against the commercial iodide/triiodide electrolyte solution and fluorine-doped tin oxide (FTO) electrode in order to increase the solar cell lifetime. The sealing strength of the laser-sealed $V_2O_5-TeO_2$-based glass frit is $20.5{\pm}1.7MPa$, which is higher than those of thermally sealed glass frit and other reported glass frit. Furthermore, the developed glass frit is chemically stable against electrolyte solutions. The glass frit constituents are not leached out from the glass after soaking in the electrolyte solution for up to three months. During the laser sealing, the glass frit does not react with the FTO electrode; thus, the resistivity of the FTO electrode beneath the laser-sealed area remains the same.

AN EXPERIMENTAL STUDY ON THE EFFECT OF ULTRASONIC INSTRUMENTATION ON THE ROOT CANAL OBTURATION (Ultrasonic Instrumentation이 근관충전에 미치는 영향에 관한 연구)

  • Hur, Soo-Beom;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.181-189
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of apical seal produced by ultrasonic instrumentation. 120 extracted, permanent single rooted teeth were randomly divided into 6 groups of 20 teeth and root canals were enlarged & obturated according to Table I. After canal obturation, the obturated teeth were immersed in 2.5 % Methylene blue for 72 hrs. at $37^{\circ}C$ incubator and longitudinally sectioned. The apical sealing ability was evaluated by measuring the degree of dye penetration into the canal. The results were as follows: 1. All groups showed varying depth of dye penetration. 2. There were no significant differences between Group I and N, Group II and V, Group III and VI. (P>0.05) 3. Regardless of obturation method, there were no significant differences between hand instrumented group and ultrasonic instrumented group.(P>0.05).

  • PDF