DOI QR코드

DOI QR Code

TRACE V5 CODE APPLICATION DVI LINE BREAK LOCA USING ATLAS FACILITY

  • Received : 2012.05.23
  • Published : 2012.10.25

Abstract

The object of this work is the validation and assessment of the TRACE v5.0 code using the scaled test ATLAS1 facility in the context of a DVI2 line break. In particular, the experiment selected models the 50%, 6-inch break of a DVI line. The same experiment was also adopted as a reference test in the ISP-503. The ISP-50 was proposed to, and accepted by, the OECD/NEA/CSNI due to its technical importance in the development of a best-estimate of safety analysis methodology for DVI line break accidents. In particular, the behavior of the two-phase flow in the upper annulus downcomer was expected to be complicated. What resulted was the need for relevant models to be implemented into safety analysis codes, in order to predict these thermal hydraulic phenomena correctly.

Keywords

References

  1. Kim, Y. S. et al, "Commissioning of the ATLAS Thermal- Hydraulic Integral Test Facility", Annals of Nuclear Energy, 35, 1791 (2008) https://doi.org/10.1016/j.anucene.2008.05.010
  2. K. Y. Choi et al., "Final IntegrationReport of International Standard Problem $N^{\circ}$50", NEA/CSNI/R(2012)6, Feb. 2012
  3. Kataoka, M. Ishii and I., "Similarity Analysis and Scaling Criteria for LWRs Under Single Phase and Two-Phase Natural Circulation", NUREG/CR-3267, Argonne National Laboratory, ANL-83-32, 1983
  4. Kyoung-Ho K, "ATLAS Facility and Instrumentation Description Report", KAERI/TR-3779/2009, June 2009
  5. K. H. Kang et al., "Detailed Description Report of ATLAS Facility and Instrumentation", KAERI/TR-4316/2011
  6. KyoungHo K, "ATLAS Facility and Instrumentation Description Report", KAERI/TR-3779/2009
  7. K. Y. Choi et al., "ISP-50 Specifications for a Direct Vessel Injection Line Break Test with the ATLAS", KAERI/TR- 3778/2009
  8. J. Liebert, R. Emmerling, "UPTF experiment Flow phenomena during full-scale loop seal clearing of a PWR"