• 제목/요약/키워드: V-factor

검색결과 2,460건 처리시간 0.03초

4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준 (Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings)

  • 김희동
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

NOTE ON CONNECTED (g, f)-FACTORS OF GRAPHS

  • Zhou, Sizhong;Wu, Jiancheng;Pan, Quanru
    • Journal of applied mathematics & informatics
    • /
    • 제28권3_4호
    • /
    • pp.909-912
    • /
    • 2010
  • In this note we present a short proof of the following result by Zhou, Liu and Xu. Let G be a graph of order n, and let a and b be two integers with 1 $\leq$ a < b and b $\geq$ 3, and let g and f be two integer-valued functions defined on V(G) such that a $\leq$ g(x) < f(x) $\leq$ b for each $x\;{\in}\;V(G)$ and f(V(G)) - V(G) even. If $n\;{\geq}\;\frac{(a+b-1)^2+1}{a}$ and $\delta(G)\;{\geq}\;\frac{(b-1)n}{a+b-1}$,then G has a connected (g, f)-factor.

전조등 조도변동에 대한 운전자의 인식연구 : 3. 운전자의 심리적 특성 (A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 3. Driver's psychological property)

  • 김현지;김현진;김기훈;김훈;안옥희
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.19-26
    • /
    • 2006
  • 본 연구는 전조등 밝기변화에 따른 운전자의 심리적 특성을 밝히기 위하여 심리평가를 실시하였다. 피험자는 20대 남, 녀 각각 20명 총 40명이며, 실험조건은 파형, 전압, 변동시간으로 구성한 32개 조건이다. 평가는 8개의 주관적 평가항목과 19쌍의 형용사로 구성된 5점 SD척도의 평가지를 사용하였다. 그 결과를 요약하면 다음과 같다. 1. SD법의 심리평가 결과, 요인분석에서 4요인으로 나타났으며, A파형은 안전감과 자극감 요인에서, B파형은 안전감 요인에서 유의차가 나타났다. 또한 A파형은 안전감 요인에서 12[V], 자극감 요인에서 11[V]가 전압변동의 한계치로 나타났으며, B파형에서는 안전감 요인이 12.6[V]가 한계치로 나타났다. 2. 주관적 평가 결과, A파형의 밝기변화의 한계치는 12[V]로 나타났다. 또한B파형의 밝기변화는 12.67[V], 불쾌감은 12.12[V], 어두워짐에 대해서는 12.71[V]가 전압변동의 한계치로 나타났다. C파형의 밝기변화의 한계치는 12[V]로 나타났다.

Ti/SiC(4H) 쇼트키 장벽 다이오드의 전기적 특성 (The electrical properties of a Ti/SiC(4H) sehottky diode)

  • 박국상;김정윤;이기암;장성주
    • 한국결정성장학회지
    • /
    • 제7권3호
    • /
    • pp.487-493
    • /
    • 1997
  • SiC(4H) 결정에 Ti을 열증착하여 Ti/SiC(4H) 쇼트키(Schottky) 장벽 다이오드를 만들었다. SiC(4H)의 주개농도(donor concentration)는 전기용량-전압(C-V) 측정으로부터 $2.0{\times}10^{15}{\textrm}{cm}^{-3}$이었으며, 내부전위(built-in potential)는 0.65 V이었다. 전류-전압(I-V) 특성으로 부터 다이오드의 이상계수(ideally factor)는 1.07이었으며, 역방향 항복전장(breakdown field)은 약 $1.7{\times}10^3V/{\textrm}{cm}$이었다. 상온에서 $140^{\circ}C$까지 온도변화에 따라 측정된 포화전류로 부터 구한 전위장벽(potential barrier)은 0.91 V이었는데, 이는 C-V 특성으로 부터 구한 전위장벽과 거의 같았다.

  • PDF

구조용 강의 굽힘 피로강도에 미치는 Notch의 영향 (The Effect of Notch on Bending Fatigue Strength of Structural Steel)

  • 박노석
    • Journal of Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.64-72
    • /
    • 1976
  • This experimental work was carried out to investigate the fatigue bending strength on various shapes and sizes of notches of the domestically manufactured steel plate. The notch types tested were a circular hole, U-and V-notches. The S-N diagram for different notch shapes were discussed in relation to plan bending strength and stress concentration factor of notches .The results of the experiments are summarized as follows : (1) The difference between stress concentration factor and notch factor was greater as the radium of notch root became smaller, and these values approached to an identical value as the radium of notch root increased. (2) It was shown that the plane bending fatigue limit of bar without notch for the hotrolled steel having the tensile strength of 33.1kg/$mm^2$was 17.0kg/$mm^2$. (3) U-and V-notch had a greater effect of stress concentration factor on the endurance limit, but O-hole showed the same effect only for $\o\pm2mm$. (4) For the same radius of notch root, U-notch showed a lower value of fatigue limit compared to V-notch and O-hole.

  • PDF

3상 Single Stage 방식의 48V/100A급 고효율 고역률 직류 전원장치 (High efficiency and power factor 48V/100A DC power supply of three-phase single stage method)

  • 박진영;김경환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.430-432
    • /
    • 2005
  • This paper presents a novel, single stage, isolated, three-phase switching rectifier capable of switching at high frequency. The circuit topology Provides zero-voltage switching for all switches, output voltage regulation, unity input power factor, all in a single power conversion stage. Operating principle and experimental results in the 48V/100A DC power supply of three-phase single stage method are presented.

  • PDF

콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가 (Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography)

  • 한진우
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.353-360
    • /
    • 2020
  • 본 연구는 CBCT 장비의 표준 노출 조건(80 kV, 7 mA)을 기준으로 관전압과 관전류를 낮추어 촬영하면서 표준 노출 조건의 물리적 화질 요소값을 유지할 수 있는 노출 조건의 제시를 목표로 두고자한다. 영상의 물리적 화질 요소값의 측정을 위해 변조전달함수(MTF)가 분석되었고 선량 측정을 위해 선량-면적 곱(DAP)을 이용하였다. 관전압(80, 78, 76 kV)과 관전류(7, 6, 5, 4, 3 mA)의 15가지 조합의 노출 조건에서 Sedent ex IQ 팬텀 (Leeds Test Objects Ltd., Boroughbridge, UK)의 CBCT 영상을 얻었고 MTF 10이 각 조건에서 계산 되었다. 표준 노출 조건과 비교시 80 kV-6 mA, 80 kV-5 mA 노출 조건은 MTF 10에 있어 유의한 차이를 보이지 않았기에 본 연구에서 사용된 CBCT 장비의 경우, 80 kV-5 mA로 낮춘 노출 조건에서 물리적 화질요소값을 유지하면서 선량을 감소시킬 수 있는 것으로 판단되어진다.

1차 및 2차 복합 하중을 받는 구조물의 탄소성 파괴역학 매개변수 예측기법 (Simplified estimations of elastic-plastic fracture mechanics parameters under combined primary and secondary loadings)

  • 오창균;김윤재;박진무;김종성;진태은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.43-48
    • /
    • 2004
  • When structures are loaded by a combination of primary and secondary stresses, plasticity effects occur which cannot be evaluated by a simple linear addition of the effects resulting from the two independent stress systems. Thermal stress due to temperature gradient is classified as secondary stress. It is known that secondary stress is released as increase of plastic zone. In this paper, two and three dimensional elastic-plastic finite element analyses are performed for the cracked plates and pipes under combined thermal and mechanical loading. And V-factor is introduced to account for plasticity effect. The present results provide that V-factor is function of thermal factor and loading and is consistent regardless of geometry. We developed the prediction method of elastic-plastic fracture mechanics parameter under combined primary and secondary loading from the present results.

  • PDF

A Novel Zero-Crossing Compensation Scheme for Fixed Off-Time Controlled High Power Factor AC-DC LED Drivers

  • Chang, Changyuan;Sun, Hailong;Zhu, Wenwen;Chen, Yao;Wang, Chenhao
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1661-1668
    • /
    • 2016
  • A fixed off-time controlled high power factor ac-dc LED driver is proposed in this paper, which employs a novel zero-crossing-compensation (ZCC) circuit based on a fixed off-time controlled scheme. Due to the parasitic parameters of the system, the practical waveforms have a dead region. By detecting the zero-crossing boundary, the proposed ZCC circuit compensates the control signal VCOMP within the dead region, and is invalid above this region. With further optimization of the parameters KR and Kτ of the ZCC circuit, the dead zone can be eliminated and lower THD is achieved. Finally, the chip is implemented in HHNEC 0.5μm 5V/40V HVCMOS process, and a prototype circuit, delivering 7~12W of power to several 3-W LED loads, is tested under AC input voltage ranging from 85V to 265V. The test results indicate that the average total harmonic distortion (THD) of the entire system is approximately 10%, with a minimum of 5.5%, and that the power factor is above 0.955, with a maximum of 0.999.

6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성 (Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings)

  • 김희동;공태식
    • 한국전기전자재료학회논문지
    • /
    • 제25권4호
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.