• Title/Summary/Keyword: V-factor

Search Result 2,456, Processing Time 0.029 seconds

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

NOTE ON CONNECTED (g, f)-FACTORS OF GRAPHS

  • Zhou, Sizhong;Wu, Jiancheng;Pan, Quanru
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.3_4
    • /
    • pp.909-912
    • /
    • 2010
  • In this note we present a short proof of the following result by Zhou, Liu and Xu. Let G be a graph of order n, and let a and b be two integers with 1 $\leq$ a < b and b $\geq$ 3, and let g and f be two integer-valued functions defined on V(G) such that a $\leq$ g(x) < f(x) $\leq$ b for each $x\;{\in}\;V(G)$ and f(V(G)) - V(G) even. If $n\;{\geq}\;\frac{(a+b-1)^2+1}{a}$ and $\delta(G)\;{\geq}\;\frac{(b-1)n}{a+b-1}$,then G has a connected (g, f)-factor.

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 3. Driver's psychological property (전조등 조도변동에 대한 운전자의 인식연구 : 3. 운전자의 심리적 특성)

  • Kim, Huyn-Ji;Kim, Hyun-Jin;Kim, Gi-Hoon;Kim, Hoon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.19-26
    • /
    • 2006
  • In this study, psychological assessment was carried out to investigate the driver's psychological characteristics by the change of the headlight. The participants were 20 men and 20 women in their 20s and thirty-two different conditions in combinations of waveform of light, voltage, and alteration time were used. The questionnaire for the assessment was evaluated by 8 subjective item and 5-point SD criteria of 19 pair's adjective. The results were as follows : 1. The assessment results from SD method indicated 4 factors by factor analysis, and it was shown that A waveform had significances in a sense of security and impetus and B waveform had a significance in a sense of security. The levels of the limitations for the voltage change were 12[V] in the factor of a sense of security and 11[V] in the factor of a sense of impetus for A waveform, 12.6[V] in the factor of a sense of security for B waveform. 2. The results of the subjective assessment showed that the limitation of A waveform's brightness change was 12[V]. Moreover, the limitations of voltage changes were 12.67[V] for B waveform brightness change, 12.12[V] for discomfort, 12.71[V] for darkness. And the limitation of C waveform's brightness change was 12[V].

The electrical properties of a Ti/SiC(4H) sehottky diode (Ti/SiC(4H) 쇼트키 장벽 다이오드의 전기적 특성)

  • 박국상;김정윤;이기암;장성주
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.487-493
    • /
    • 1997
  • Ti/sic(4H) Schottky barrier diodes were fabricated. The donor concentration and the built-in potential obtained by capacitance-voltage(C-V) measurement was about $2.0{\times}10^{15}{\textrm}{cm}^{-3}$ and 0.65 V, respectively. The ideality factor of 1.07 was obtained from the slope of current-voltage(I-V) characteristics at low current density. The breakdown field under the reverse bias voltage was about $1.7{\times}10^3V/{\textrm}{cm}$ and was very high. The barrier height of Ti for SiC(4H) was 0.91 V, which was determined by the analysis of the saturation current-temperature and the C-V characteristics.

  • PDF

The Effect of Notch on Bending Fatigue Strength of Structural Steel (구조용 강의 굽힘 피로강도에 미치는 Notch의 영향)

  • 박노석
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.64-72
    • /
    • 1976
  • This experimental work was carried out to investigate the fatigue bending strength on various shapes and sizes of notches of the domestically manufactured steel plate. The notch types tested were a circular hole, U-and V-notches. The S-N diagram for different notch shapes were discussed in relation to plan bending strength and stress concentration factor of notches .The results of the experiments are summarized as follows : (1) The difference between stress concentration factor and notch factor was greater as the radium of notch root became smaller, and these values approached to an identical value as the radium of notch root increased. (2) It was shown that the plane bending fatigue limit of bar without notch for the hotrolled steel having the tensile strength of 33.1kg/$mm^2$was 17.0kg/$mm^2$. (3) U-and V-notch had a greater effect of stress concentration factor on the endurance limit, but O-hole showed the same effect only for $\o\pm2mm$. (4) For the same radius of notch root, U-notch showed a lower value of fatigue limit compared to V-notch and O-hole.

  • PDF

High efficiency and power factor 48V/100A DC power supply of three-phase single stage method (3상 Single Stage 방식의 48V/100A급 고효율 고역률 직류 전원장치)

  • Park, J.Y.;Kim, K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.430-432
    • /
    • 2005
  • This paper presents a novel, single stage, isolated, three-phase switching rectifier capable of switching at high frequency. The circuit topology Provides zero-voltage switching for all switches, output voltage regulation, unity input power factor, all in a single power conversion stage. Operating principle and experimental results in the 48V/100A DC power supply of three-phase single stage method are presented.

  • PDF

Evaluation of Dose Reduction and Maintaining Image Quality according to Exposure Factors of Cone Beam Computed Tomography (콘빔전산화단층촬영에서 노출 조건에 따른 화질 유지 및 선량 감소에 대한 평가)

  • Han, Jin-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.353-360
    • /
    • 2020
  • This research aims at suggesting exposure condition that shows maintaining the value of the physical image quality factor by decreasing tube voltage and tube current from the standard exposure condition(80 kV, 7 mA) of a CBCT apparatus. To measure the value of the physical image quality factor, modular transfer function(MTF) was analyzed and dose-area product(DAP) was used for the measurement of exposure dose. CBCT images of a Sedentex IQ phantom were obtained under 15 exposure conditions of different combination of tube voltage(80, 78, 76 kV) and tube current(7, 6, 5, 4, 3 mA) and MTF 10 was calculated under each exposure conditions. There were no significant differences in MTF 10 under 80 kV-6 mA, 80 kV-5 mA exposure conditions in comparison with standard exposure condition. Based on the results of this research, 80 kV-5 mA condition are expected to be able to reduce exposure dose with maintaining the value of the physical image quality factor of the standard exposure condition.

Simplified estimations of elastic-plastic fracture mechanics parameters under combined primary and secondary loadings (1차 및 2차 복합 하중을 받는 구조물의 탄소성 파괴역학 매개변수 예측기법)

  • Oh, Chang-Kyun;Kim, Yun-Jae;Park, Jin-Moo;Kim, Jong-Sung;Jin, Tae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.43-48
    • /
    • 2004
  • When structures are loaded by a combination of primary and secondary stresses, plasticity effects occur which cannot be evaluated by a simple linear addition of the effects resulting from the two independent stress systems. Thermal stress due to temperature gradient is classified as secondary stress. It is known that secondary stress is released as increase of plastic zone. In this paper, two and three dimensional elastic-plastic finite element analyses are performed for the cracked plates and pipes under combined thermal and mechanical loading. And V-factor is introduced to account for plasticity effect. The present results provide that V-factor is function of thermal factor and loading and is consistent regardless of geometry. We developed the prediction method of elastic-plastic fracture mechanics parameter under combined primary and secondary loading from the present results.

  • PDF

A Novel Zero-Crossing Compensation Scheme for Fixed Off-Time Controlled High Power Factor AC-DC LED Drivers

  • Chang, Changyuan;Sun, Hailong;Zhu, Wenwen;Chen, Yao;Wang, Chenhao
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1661-1668
    • /
    • 2016
  • A fixed off-time controlled high power factor ac-dc LED driver is proposed in this paper, which employs a novel zero-crossing-compensation (ZCC) circuit based on a fixed off-time controlled scheme. Due to the parasitic parameters of the system, the practical waveforms have a dead region. By detecting the zero-crossing boundary, the proposed ZCC circuit compensates the control signal VCOMP within the dead region, and is invalid above this region. With further optimization of the parameters KR and Kτ of the ZCC circuit, the dead zone can be eliminated and lower THD is achieved. Finally, the chip is implemented in HHNEC 0.5μm 5V/40V HVCMOS process, and a prototype circuit, delivering 7~12W of power to several 3-W LED loads, is tested under AC input voltage ranging from 85V to 265V. The test results indicate that the average total harmonic distortion (THD) of the entire system is approximately 10%, with a minimum of 5.5%, and that the power factor is above 0.955, with a maximum of 0.999.

Characteristics of Insulation Diagnosis and Failure in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연파괴 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • To assess the condition of stator insulation, nondestructive and overpotential tests were performed on four high voltage motors. The stator windings under these tests have nominal ratings of 6.6 kV. After completing nondestructive tests, the AC overvoltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No. 1, No. 2, No. 3 and No. 4 of 6.6 kV motors failed near rated voltage of 18.4 kV, 19.8 kV, 19.7 kV and 21.7 kV, respectively. The breakdown voltage of four motors was higher that expected for good quality coils(14.2 kV) in 6.6 kV motors. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor($tan{\delta}$) and partial discharge magnitude.