• Title/Summary/Keyword: V-Factor

Search Result 2,486, Processing Time 0.035 seconds

Study on the subgrade reaction modulus$(K_{30})$ and strain modulus$(E_v)$ (지반반력계수$(K_{30})$와 변형률계수$(E_v)$에 대한 고찰)

  • Kim, Dae-Sang;Choi, Chan-Yong;Kim, Seong-Jung;Yu, Jin-Young;Yang, Sin-Chu
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.264-270
    • /
    • 2007
  • Two modulus, strain modulus $(E_v)$ and subgrade reaction modulus $(K_{30})$ are being used as a standard for bearing stiffness in Korea Railroad design. The first is used in Europe and the other is used in Japan. The methodologies to obtain the two modulus are similar in using plate. But testing methods are different in loading to plate. Therefore, according to soil strain range, there should be large gap in not only computations of deformation modulus but also the necessary time to test. At first, this paper focuses on the two kinds of test methods to evaluate bearing stiffness. Secondly, based on elastic theory, the theory to obtain the two coefficients are studied thoroughly. Finally, the correlations between the two coefficients were analyzed and evaluated based on the field test results more than 38 places. The matching values for subgrade and ground between $K_{30}$ and $E_{v2}$ are proposed with the consideration of the proposed strain reduction factor (1.5 for subgrade and 3 for ground) and safety factor, respectively.

Removal and Inactivation of Hepatitis A Virus during Manufacture of a High Purity Antihemophilic Factor VIII Concentrate from Human Plasma

  • Kim, In-Seop;Park, Yong-Woon;Lee, Sung-Rae;Lee, Mahl-Soon;Huh, Ki-Ho;Lee, Soungmin
    • Journal of Microbiology
    • /
    • v.39 no.1
    • /
    • pp.67-73
    • /
    • 2001
  • A validation study was conducted to evaluate the efficacy and mechanism of the cryo-precipitation, monoclonal anti-FVIIIc antibody (mAb) chromatography, Q-Sepharose chromatography, and lyophilization steps involved in the manufacture of high purity factor VIII (GreenMono) from human plasma, in the removal and/or inactivation of hepatitis A virus (HAV). Samples from the relevant stages of the production process were spiked with HAV and subjected to scale-down processes mimicking the manufacture of the high purity factor VIII concentrate. Samples were collected at each step and immediately titrated using a 50% tissue culture infectious dose (TCID$\_$50/) and then the virus reduction factors were evaluated. HAV was effectively partitioned from factor VⅢ during cryo-precipitation with the log reduction factor of 3.2. The mAb chromatography was the most effective step far removal of HAV with the log reduction factor of $\geq$4.3. HAV infectivity was not detected in the fraction of factor VⅢ, while most of HAV infectivity was recovered in the fractions of flow through and wash during mAb chromatography. Q-Sepharose chromatography showed the lowest efficacy for partitioning HAV with the log reduction factor of 0.7. Lyophilization was an effective step in inactivating HAV with the log reduction factor of 2.3. The cumulative lag reduction factor, $\geq$10.5, achieved for tile entire manufacturing process was several magnitudes greater than the potential HAV load of current plasma pools.

  • PDF

Evaluation and Analysis on the Image Decision Factors of Food Service Industry - Focused on Jeonju Local Food Service Industry - (외식업체 서비스 이미지 결정 요인 평가 분석 - 전주 지역 외식업체 중심으로 -)

  • Yang, Man-Kyu
    • Culinary science and hospitality research
    • /
    • v.16 no.2
    • /
    • pp.1-14
    • /
    • 2010
  • This study is focused on the image benefit cost criterion value and the pure image benefit figure of the local food service industries, V, T, and O based on the theory and factor-analyses of food service industry. To accomplish the aim of this study, theoretical and positive research methods have been applied. The steps of food service image decision projects for the activating of identification on food service have been examined through theories and positive analyses. As the results, 'the image of menu service' appears to be the most effectual factor on the pure image benefit score, which is the priority order of the project planning for the food service image marketing of Jeonju area. As for the image benefit cost criterion value, 'the image of managemental service system', 'the image of approachability', and 'the service of internal surroundings' have been proved to be the most effectual factor in V, T, O respectively. On the other hand, this study shows that V manages its image of food service most effectually with 1.7 billion won, T with 96 million won, O with 7.2 million won for the image marketing strategy.

  • PDF

A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy (확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구)

  • Lee, Jeong-U;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

RANDOMLY ORTHOGONAL FACTORIZATIONS OF (0,mf - (m - 1)r)-GRAPHS

  • Zhou, Sizhong;Zong, Minggang
    • Journal of the Korean Mathematical Society
    • /
    • v.45 no.6
    • /
    • pp.1613-1622
    • /
    • 2008
  • Let G be a graph with vertex set V(G) and edge set E(G), and let g, f be two nonnegative integer-valued functions defined on V(G) such that $g(x)\;{\leq}\;f(x)$ for every vertex x of V(G). We use $d_G(x)$ to denote the degree of a vertex x of G. A (g, f)-factor of G is a spanning subgraph F of G such that $g(x)\;{\leq}\;d_F(x)\;{\leq}\;f(x)$ for every vertex x of V(F). In particular, G is called a (g, f)-graph if G itself is a (g, f)-factor. A (g, f)-factorization of G is a partition of E(G) into edge-disjoint (g, f)-factors. Let F = {$F_1$, $F_2$, ..., $F_m$} be a factorization of G and H be a subgraph of G with mr edges. If $F_i$, $1\;{\leq}\;i\;{\leq}\;m$, has exactly r edges in common with H, we say that F is r-orthogonal to H. If for any partition {$A_1$, $A_2$, ..., $A_m$} of E(H) with $|A_i|=r$ there is a (g, f)-factorization F = {$F_1$, $F_2$, ..., $F_m$} of G such that $A_i\;{\subseteq}E(F_i)$, $1\;{\leq}\;i\;{\leq}\;m$, then we say that G has (g, f)-factorizations randomly r-orthogonal to H. In this paper it is proved that every (0, mf - (m - 1)r)-graph has (0, f)-factorizations randomly r-orthogonal to any given subgraph with mr edges if $f(x)\;{\geq}\;3r\;-\;1$ for any $x\;{\in}\;V(G)$.

A Study About Electrical Properties and Fabrication Schottky Barrirer Diode Prepared on Polar/Non-Polar of 6H-SiC (극성/무극성 6H-SiC 쇼트키 베리어 다이오드 제조 및 전기적 특성 연구)

  • Kim, Kyung-Min;Park, Sung-Hyun;Lee, Won-Jae;Shin, Byoung-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.8
    • /
    • pp.587-592
    • /
    • 2010
  • We have fabricated schottky barrier diode (SBDs) using polar (c-plane) and non polar (a-, m-plane) n-type 6H-SiC wafers. Ni/SiC ohmic contact was accomplished on the backside of the SiC wafers by thermal evaporation and annealed for 20minutes at $950^{\circ}C$ in mixture gas ($N_2$ 90% + $H_2$ balanced). The specific contact resistance was $3.6{\times}10^{-4}{\Omega}cm^2$ after annealing at $950^{\circ}C$. The XRD results of the alloyed contact layer show that formation of $NiSi_2$ layer might be responsible for the ohmic contact. The active rectifying electrode was formed by the same thermal evaporation of Ni thin film on topside of the SiC wafers and annealed for 5 minutes at $500^{\circ}C$ in mixture gas ($N_2$ 90% + $H_2$ balanced). The electrical properties of SBDs have been characterized by means of I-V and C-V curves. The forward voltage drop is about 0.95 V, 0.8 V and 0.8 V for c-, a- and m-plane SiC SBDs respectively. The ideality factor (${\eta}$) of all SBDs have been calculated from log(I)-V plot. The values of ideality factor were 1.46, 1.46 and 1.61 for c-, a- and m-plane SiC SBDs, respectively. The schottky barrier height (SBH) of all SBDs have been calculated from C-V curve. The values of SBH were 1.37 eV, 1.09 eV and 1.02 eV for c-, a- and m-plane SiC SBDs, respectively.

The Chemotoxonoic Relationship of Vibrio cholerae non-O1 by Fatty Acid Compositions (지방산 조성에 의한 vibrio cholerae non-O1의 화학분류학적 관계)

  • 성희경;이원재;장동성
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.2
    • /
    • pp.149-154
    • /
    • 1998
  • The authors attempted utilization of fatty acid composition of vibrios as a tool for identification of the strains. Fatty acid of 49 strains of Vibrio cholerae non-O1, V. cholerae O1, V mimicus, V vulinificus and V parahaemolyticus was analyzed by gas-liquid chromatography column. According to the statistical analysis of the fatty acid data, the relationship between the Vibrio species and serotypes of the strains was discussed. Forty one kinds of fatty acid were detected from the tested strains and 35 kinds of fatty acids among the detected fatty acids were significant factors to identify the vibrios. The predominant fatty acids were 16:0, 16:1 cis 9, 18:1 trans 9/6/cis 11 and 15:0 iso 2OH/16:1 cis 9 as above about 20% in total. Fatty acid compositions of the Vibrio species were an important factor in identifying their subspecies either predominant fatty acids or minor ones. According to the analysed results by a conventional statistical processing method (UPGMA) and prepared dendrogram, V cholerae non-01 had more closer relationship with V. mimicus compared with V. cholerae 01. Moreover, the distribution of hydroxy acid was a significant factor for identifying V cholerae subspecies. Comprising all the 10 serotypes detected from V. cholerae non-01 examined such as O2, O5, O8, O10, O14, O27, O37, O39, O45 and O69, we could group them into seven subspecies by cluster analysis with the similarity value of fatty acid composition as above 92%. It means that there is a significant relationship between serotypes and fatty acid composition of V. cholerae. These results indicated that numerical analysis of fatty acid composition data of V cholerae non-01 could classifY them into subspecies, and also which may provide a useful epidemiologic information or a basis for further analysis such as PCR and DNA probe analysis.

  • PDF

Characteristics of Dissipation Factor in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 유전정접 특성)

  • Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.93-94
    • /
    • 2008
  • Diagnostic tests were performed in three high voltage motors. These tests included insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharge magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. NO.1 and No.2 motors failed near rated voltage of 14.0 kV, respectively. These motors are lower that expected for good quality coils in 6.6 kV class motors. The breakdown voltage of No.3 motor was 15.0 kV.

  • PDF

Causal relationship study of human sense for odor

  • Kaneki, N.;Shimada, K.;Yamada, H.;Miura, T.;Kamimura, H.;Tanaka, H.
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.257-260
    • /
    • 2002
  • The impressions for odors are subjective and have individual differences. In this study, the Impressions of odors were investigated by covariance structure analysis. 46 subjects (men in their twenty) recorded their reactions to ten odorants by grading them on a seven-point scale in terms of twelve adjective pairs. Their reactions were quantified by using factor analysis and covariance structure analysis. The factors were extracted as "preference", "arousal" and "persistency". The subjects were classified into three groups according to the most suitable causal models (structural equation models). Each group had different causal relationship and different impression structure for odors. It was suggested that there is a possibility to evaluate the subjective impression of odor using covariance structure analysis.

  • PDF

The Inductor Characteristics of the PFC Converter for Wireless Power Transfer Inverter (무선전력전송 인버터 전원용 PFC 컨버터의 인덕터 특성)

  • LIM, Seongjin;KIM, Changsun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.534-535
    • /
    • 2012
  • The characteristics of wireless power transfer is achieved at high frequencies in short range magnetic resonant wireless power transfer system. Use PFC pre-regulator for power supply of high frequency inverter. Supplied power to high power factor and high efficiency. Accordingly, the input voltage is 110V-220V. The designed of 175W Class with the output voltage of 385V. As a experiment result, maximum power factor and maximum efficiency measured 99% and 97% respectively. Therefore, in this paper, the design of a inductor which is the most important element in PFC converter for short range magnetic resonance wireless power transfer system was studied. Used an CS330125 core through the designed of 175W class. Examination results power loss was 0.2%.

  • PDF