• Title/Summary/Keyword: V-곡선

Search Result 773, Processing Time 0.033 seconds

A study on the characteristic of material using V(z) curve of acoustic microscope (음향현미경의 V(z)곡선을 이용한 재료의 특성에 관한 연구)

  • Moon, G.;Ko, D.S.;Jun, K.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.65-73
    • /
    • 1988
  • In this paper, V(z) curve has been analyzed theoretically and compared with the experimental result, and the relation between the V(z) curve and the material characteristic has been studied. Angular spectrum and ray optics theory have been used for theoretical analysis and the acoustic microscope operating at a center frequency of 3 MHz has been used for experiment. In experiment, it has been shown that each material has a V(z) curve of a unique form and the interval of dips appearing in the V(z) curves have been used to determine the Rayleigh wave velocity.

  • PDF

Simulation of V(z) curve at the Acoustic Microscope (초음파현미경에서 V(z)곡선의 시뮬레이션)

  • 박익근;임재생;윤종학;노승남;서성원
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.426-430
    • /
    • 2003
  • 본 연구에서는 초음파현미경의 기하학적 원리와 초음파현미경의 특징중 하나인 V(z)곡선의 간섭파형을 시뮬레이션 하였고, 실제 초음파현미경의 V(z)곡선법을 이용하여 미소영역에서의 누설탄성표면파 음속을 측정하였다. 초음파현미경을 이용한 V(z)곡선법의 음속측정결과가 시뮬레이션 음속값과 큰차이를 보이지 않으므로 미소영역에 초음파현미경의 V(z)곡선법을 적용하여 초음파의 음속측정이 가능함을 확인하였다. 이는 향후 초음파현미경을 이용하여 미세한 재료의 물성평가에 적용할 수 있을 것으로 기대된다.

  • PDF

Linearization Method of V-I Characteristic for MMC HVDC Conduction Losses Calculation (MMC HVDC의 전도 손실 계산을 위한 V-I 특성 곡선 근사 방법)

  • Na, Jongseo;Kim, Sangmin;Kim, Heejin;Jeong, Jongkyou;Hur, Kyeon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.303-304
    • /
    • 2019
  • 본 논문에서는 모듈러 멀티레벨 컨버터(Modular Multilevel Converter, MMC) 고압직류송전(High Voltage Direct Current, HVDC)의 전도 손실 계산을 위한 반도체 스위치 V-I 특성 곡선 근사 방법을 제안한다. 일반적으로 V-I 특성 곡선은 정격 전류 구간에 대해서만 선형화하여 사용하지만, MMC HVDC의 경우 암 전류의 직류 오프셋에 의해 V-I 특성 곡선의 비선형 구간에서 손실 계산에 오차가 크게 나타난다. 따라서 본 논문에서는 암 전류의 부호에 따라 별도의 V-I 특성 곡선 근사를 적용하여 MMC HVDC의 전도 손실 계산의 정확성을 향상하는 방안을 제안한다. 전도 손실 계산 결과는 PSCAD 시뮬레이션으로 취득한 손실 값과 비교하여 결과를 검증하였다.

  • PDF

A Study on the Distinction of Solid Characteristics Using Focused Acoustic Wave (집속음향파를 이용한 고체특성 판별에 관한 연구)

  • Moon, Gun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.1
    • /
    • pp.92-99
    • /
    • 1993
  • On this study. Constructed the system detecting the reflective acoustic waves from the solid-samples using the 3MHZ focused-acoustic transducer and detected the V(Z) charateristics curves varied by the distance between the focusing position and the solid surface. The results of the experimental detection to various solid materials showed that the materials have their own unique shape of V(Z) curves. This paper suggested the possibility distinguishing the solid characteristics by analysing the V (Z) curves.

  • PDF

LIGHT CURVE ANALYSIS OF CONTACT BINARY SYSTEM V523 CASSIOPEIAE (접촉쌍성 V523 CAS의 광도곡선 분석)

  • 김진희;정장해
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.263-272
    • /
    • 2002
  • A total of 616 observations (308 in B, 308 in V) to. V523 Cas was made on three nights from October 19 to 21 in 1999 using the 1.8m telescope with 2K CCD camera of the Bohyunsan Optical Astronomy Observatory of KAO. With our data we constructed the BV light curves and determined 4 times of minimum light. We also obtained physical parameters of the system by combined analysis of both light and radial velocity curves using the Wilson-Devinney code.

Hyperelliptic Cryptosystems of Genus 2 (Genus 2인 초타원 암호시스템)

  • 김진욱;전성태;박근수
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10a
    • /
    • pp.643-645
    • /
    • 1999
  • 타원곡선에 이어 초타원곡선을 공개키 암호시스템에 적용하는 방법이 Koblitz에 의해 제안되었다. 이를 위해 우선 곡선을 선택해야 하는데, 선택될 곡선은 현재까지 알려진 공격에 대해 안전하여야 한다. 본 논문에서는 초타원 암호시스템(hyperelliptic cryptosystem을 구성하기 위해 genus 2인 초타원곡선 v2+v=u5+u3+u와 특성계수(characteristic) 3인 기본 체(field)를 선택하고, 이로써 만들어질 암호시스템이 안전함을 보인다.

  • PDF

Extraction and Modeling of High-Temperature Dependent Capacitance-Voltage Curve for RF MOSFETs (고온 종속 RF MOSFET 캐패시턴스-전압 곡선 추출 및 모델링)

  • Ko, Bong-Hyuk;Lee, Seong-Hearn
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.10
    • /
    • pp.1-6
    • /
    • 2010
  • In this paper, RF Capacitance-Voltage(C-V) curve of short-channel MOSFET has been extracted from the room temperature to $225^{\circ}C$ using a RF method based on measured S-parameter data, and its high-temperature dependent characteristics are empirically modeled. It is observed that the voltage shift according to the variation of temperature in the weak inversion region of RF C-V curves is lower than the threshold voltage shift, but it is confirmed that this phenomenon is unexplainable with a long-channel theoretical C-V equation. The new empirical equation is developed for high-temperature dependent modeling of short-channel MOSFET C-V curves. The accuracy of this equation is demonstrated by observing good agreements between the modeled and measured C-V data in the wide range of temperature. It is also confirmed that the channel capacitance decreases with increasing temperature at high gate voltage.

THE CHROMOSPHERIC ACTIVITY ON V711 TAU (V711 TAU의 채층활동)

  • V771TAU의채층활동
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 1997
  • The relationship between Mg II emission line and light variation of V711 Tau has been derived to investigate the chromospheric activity on V711 Tau. First, a shape of an optical light curve was compared with that of ultraviolet constructed from the IUE low resolution spectra. Second, the intensities of Mg II k emission lines have been reduced from IUE high resolution spectra. The intensity of Mg II k line was compared with brightness of the UV light curve at given phase. The Mg II line intensity is maximum at the phase $O.^{P}4$ where the light is minimum. The evidence of chromosperic activity is indicated by the intensity variation of the MgII emission line with orbital phase for V711 Tau.

  • PDF

V345 Cas의 주기변화와 광도곡선 분석

  • Jeong, Min-Ji;Kim, Cheon-Hwi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.142.2-142.2
    • /
    • 2012
  • Hoffmeister(1943)에 의해 변광성으로 발견된 V345 Cas (2MASS J23083986+5406545, ${\alpha}$(2000.0)=23h08m39.86s & ${\delta}(2000.0)=+54^{\circ}06^{\prime}54.6^{\prime\prime}$)는 B 필터에서 13.1~14.2의 광도 변화를 보이는 것으로 알려진 별이다. 우리는 레몬산 천문대(LOAO)에서 2007년과 2008년에 걸쳐 총 22일간 V345 Cas의 BVRI CCD 측광관측을 수행하여, 처음으로 V345 Cas의 년도 별 전체 광도곡선을 완성하였다. 우리의 관측 자료와 Super WASP에서 공개한 자료를 이용하여 각각 7개의 극심시각을 산출하였다. 우리가 결정한 극심시각을 포함하여 여러 문헌에서 수집한 총 68개의 극심시각을 이용하여 V345 Cas의 주기 분석을 수행하였다. 그 결과, V345 Cas의 궤도주기는 포물선 모양의 영년변화와 함께 약 30년의 규칙적인 변화를 겪고 있음을 발견하였다. 규칙적인 변화를 제3천체에 의한 광시간 효과로 가정하여 관측된 극심시각에 잘 맞는 광시간 궤도 해를 산출한 결과, 영년주기가 증가하는 경우와 감소하는 경우에 대해, 각각 29.0년과 39.7년 주기를 갖는 두 개의 광시간 궤도 해가 가능하다. 이러한 모호성을 해결하기 위해서 앞으로의 극심시각 관측이 중요하다. 2007년과 2008년 BVRI 광도곡선들은 부극심을 기준으로 좌우가 거의 대칭이며, 1년 사이에 특기할 만한 광도변화를 보이지 않았다. 우리는 이 광도곡선들을 Wilson-Devinney 쌍성 모델을 이용하여 분석하여, V345 Cas의 측광학적 해를 처음으로 산출하였다. 우리가 구한 해에 의하면, 약 88도의 궤도경사각에 두 성분별의 질량비가 약 0.5인 V345 Cas는 질량과 표면 온도가 큰 주성과 로쉬 로브를 채우고 있는 반성으로 구성된 준 분리형 식쌍성계이다.

  • PDF

A Measurement and Analysis of Thermoluminescence Spectra of LaAlO3 (LaAlO3에 대한 열자극발광 스펙트럼의 광학적 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • We measured and analyzed thermoluminescence spectra of $LaAlO_3$, single crystal by 3 dimensional data for temperature, wavelength and luminescence intensity. $LaAlO_3$, has used as the substrates of YBCO(superconductor) or semiconductors. We could determined the energy of recombination center, that is impossible through analysis of glow curve data. We could obtained the energy through analysis of the spectrum data at peak temperature by Franck-Condon model. The total glow curve was deconvoluted to three glow curves by curve fitting method. The activation energies were 0.54eV, 0.91eV and 1.02eV respectively. The energies of recombination centers were determined with 2.04eV and 2.75eV from the analysis of luminescence intensity data for wavelength.

  • PDF