• Title/Summary/Keyword: Utility System

Search Result 1,826, Processing Time 0.031 seconds

Operationg Characteristics of 50kW Utility Interactive Photovoltaic System (목포대학교 기숙사 30[kW]급 태양광발전시스템 발전특성)

  • Moon, Chae-Joo;Lim, Joung-Min;Cheang, Eui-Heang;Park, Sang-Jin;Park, Gui-Yeol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.53-56
    • /
    • 2008
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system used infinity of solar energy, cost of fuel is needless and there in no air pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 30[kW] large scale applications installed in Mokpo National University dormitory roof. The status of photovoltaic system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory. In this paper represent 30[kW] utility photovoltaic system examination result.

  • PDF

A Case Study on the Information System Outsourcing based on the Utility Computing Concept (유틸리티 컴퓨팅(Utility Computing) 개념에 입각한 정보시스템 아웃소싱 사례에 대한 연구)

  • Hong, Hyun-Gi
    • Information Systems Review
    • /
    • v.7 no.2
    • /
    • pp.213-228
    • /
    • 2005
  • Due to the rapid progress of IT utilization, many firms have been perplexed how to increase the productivity and efficiency of the Information System and also to reduce the Total Cost of Ownership (TCO) of IS Organization. This paper employs the lens of the competitive advantages through Information System Outsourcing (ISO) arrangement. And also the concept of the "Utility Computing" of IBM-VNS. The Information Outsourcing System(ISO) is the fully or partly endorsed IT Outsourcing method, that supplies IT infrastructure, application system and system maintenance service, as well for the company networks. Many companies have implemented their own Information System. But some of the projects were not successfully carried out. We found many reasons for such a unsatisfaction with the quality of the new Information system. In this paper we select the "HanGlas Group" as the Case Study for Information System Outsourcing to overcome such difficulties. Through this Case Study we will learn the positive and negative aspects of ISO based on Utility Computing.

Modeling of utility interactive photovoltaic system DC-DC converter (태양광 발전 시스템용 DC-DC 컨버터의 모델링)

  • Mun, S.P.;Park, Y.J.;Kim, Y.M.;Kang, W.J.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.215-217
    • /
    • 2002
  • In this paper, a new converter for utility interactive photovoltaic system is proposed, the conventional utility interactive photovoltaic system is composed of a PWM inverter and a DC converter. However, the increased switching loss and the high frequency switching noise become a problem. the control accuracy of the system is made to lower by the dead time of the switching devices. and it becomes a cause of the lower conversion efficiency. In order to resolve those problems, we applied a non- dissipative snubber circuit to a converter, which generates the single phase absolute value of sinusoidal current. the converter consists of two switching devices and one capacitor which constitute a non-dissipative snubber circuit. the proposed circuit is very useful to minimize and increase efficiency, when it is used to an utility interactive photovoltaic system. it is confirmed by simulation that the proposed converter for new photovoltaic system has stable operation and good output.

  • PDF

Spatial Decision Support System for Residential Solar Energy Adoption

  • Ahmed O. Alzahrani;Hind Bitar;Abdulrahman Alzahrani;Khalaf O. Alsalem
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.6
    • /
    • pp.49-58
    • /
    • 2023
  • Renewable energy is not a new terminology. One of the fastest growing renewable energies is solar energy. The implementation of solar energy provides several advantages including the reduction of some of the environmental risks of fossil fuel consumption. This research elaborated the importance of the adaption of solar energy by developing a spatial decision support system (SDSS), while the Residential Solar Energy Adoption (RSEA) is an instantiation artifact in the form of an SDSS. As a GIS web-based application, RSEA allows stakeholders (e.g., utility companies, policymakers, service providers homeowners, and researchers) to navigate through locations on a map interactively. The maps highlight locations with high and low solar energy adoption potential that enables decision-makers (e.g., policymakers, solar firms, utility companies, and nonprofit organizations) to make decisions. A combined qualitative and quantitative methodological approach was used to evaluate the application's usability and user experience, and results affirmed the ability of the factors of utility, usefulness, and a positive user experience of the residential solar energy adoption of spatial decision support system (RSEA-SDSS). RSEA-SDSS in improving the decision-making process for potential various stakeholders, in utility, solar installations, policy making, and non-profit renewable energy domains.

A Utility Interactive Photovoltaic Generation System using PWM Converter (PWM 컨버터를 이용한 계통연계형 태양광발전 시스템)

  • Kim, Dae-Gyun;Jeon, Kee-Young;Hahm, Nyon-Kun;Chung, Choon-Byeong;Lee, Seung-Hwan;Oh, Bong-Hwan;Lee, Hoon-Goo;Han, Kyung-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • Since the residential load is an AC load and the output of solar cell is DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feed-forward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

A Study on the Economical PQMS of the Utility Distribution Power System (전력회사 관점의 배전계통 경제형 PQM 시스템 구축방안)

  • Park, Yong-Up;Lee, Keon-Hang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1523-1529
    • /
    • 2010
  • This paper describes the distribution power system econimical PQMS(Power quality monitoring system) of Utility. Recently, the korea power quality standard has been established based on the IEC Std. By IEC Std., the power quality assessment point is measured in PCC(Point of common coupling). In this case, the utility has to construct PQM system in all customer PCC point and the PQ meter cost would be very high in order to acquire the suitable data. Also the distribution system would be encounter the communication overload problem due to the huge data. Accordingly the utilities could not apply to PQM system in the distribution power system by the cost and communication problem. In this paper, the proposed economical PQMS has the voltage and current signal reiteration function and FFT operation function is transferred the server. Also the voltage and current measurement channels are minimized by a classified substation construction.

A Study on Preventing Transient Phenomena Due to Capacitor Switching in Distribution System involving Distributed Generation System (분산전원이 도입된 배전계통에서 커패시터 스위칭에 의한 과도현상 방지에 대한 연구)

  • Lee, D.G.;Hwang, J.S.;Ju, Y.H.;Kim, J.E.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.10-12
    • /
    • 2001
  • This paper presents a study of transient overvoltages caused by capacitor switching on the utility distribution system. Capacitor banks used for power factor correction and voltage regulation can improve efficiency of the power system. But transient voltages due to capacitor switching on the utility system affect the sensitive customer load equipments. If Distributed Generation System (DGS) is involved in the system, the problems become more serious. In this paper, effect of transient voltages at the customer load created by utility capacitor switching is analyzed by simulations Solutions to this problem are presented.

  • PDF

Operating Characteristics of 50kW Utility Interactive Photovoltaic System (조선대학교 기숙사전원용 50kW 태양광발전시스템 발전특성)

  • Park, Jeong-Min;Kim, Ji-Hun;Choi, Youn-Ok;Kim, Dae-Gon;Jang, Yong-He
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.720-722
    • /
    • 2005
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system uses infinity of solar energy, cost of fuel is needless and there is no all pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW large scale applications installed In Chosun University dormitory roof. The status of PV system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory In this paper represent 50kw utility PV system examination result

  • PDF

Research on the Effectiveness of Protecting Utility Model with China's Patent Evaluation Report (실용신안 권리보호에 대한 중국 특허권평가보고서제도의 유효성 연구)

  • Ho, Hyo-rim
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.1
    • /
    • pp.127-152
    • /
    • 2017
  • China's utility model as a supplement to the invention patent, has short application duration, fast authorized speed, and has the same exclusive rights with patents, so companies can quickly dominate the market. But the utility model does not need to carry out substantive examination, so has lower stability, high frequency of invalid to accepted, so compare with the invention patent, difficult to be protected. In order to actively encourage the small and medium-sized enterprises to promote their inventions, and protect domestic patents, China established a protection policy of patent evaluation report for the utility model rights, especially the patent evaluation report can be used as evidence in a patent infringement trial, to provide judicial remedies for utility model patentee and the party of patent disputes. Many experts believe that the establishment of patent evaluation report system can improve the stability of the utility model patent right, and when the defendant request for invalidation of the patent right in the defense period, if there is no novelty, creativity lost or no other reason has not led to the stability of patent right given in a patent evaluation report of the utility model patents, the court may not suspend the trial, without having to wait for the Patent Reexamination Board makes the patent invalid declaration decisions, can improve the efficiency of the judicial process, accelerate the patentee's time. However, in practical patent infringement, the patent evaluation report system and invalidation system are in conflict. In this paper, through the analysis of the current China utility model system and compared with the South Korean utility model system, review the role and character of the patent evaluation report system, and through the actual cases of the utility model patent infringement litigation, analysis possible variates from the decision of patent evaluation report, to find out the reason of the patent evaluation report system being in conflict with the invalidation system, and research on the effectiveness for protecting Utility Model with China's Patent Evaluation Report.

A Study on the Optimal Design of Urban Utility Systems (부하에 따른 도시기반 공급.처리시스템의 최적설계에 관한 연구)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.732-737
    • /
    • 2001
  • The mathematical method was developed and numerical analyses were carried out with various parameters to provide substantial data for optimal design and operation of urban utility systems. The composition of systems and their specifications, such as co-generation system, heat pump system, incineration system and other heating and cooling system could be obtained through these analyses for various resource and energy requirements in urban area. As results the system constituents and operating characteristics, and their economic performances such as the value of objective function, initial and an operating costs were discussed for various load patterns. The effective system design method and the excepted effects of the several unused energy recovery systems were also briefly discussed with the variation of the buildings and facilities species and their capacities.

  • PDF