• Title/Summary/Keyword: Use-dependence

Search Result 567, Processing Time 0.051 seconds

The Dependence of the Wedge Factor with the Variation of High Energy Photon Beam Fluences (고에너지 광자선의 선속 변화에 따른 쐬기인자의 의존성)

  • 오영기;윤상모;김재철;박인규;김성규
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2000
  • For wedged photon beams, the variation of the wedge factor with field size was reported by several authors. However, until now such variation with field size had not been explained quantitatively. Therefore, the variation of the wedge factor was investigated by measuring outputs with field sizes increasing from 4 cm $\times$ 4 cm to 25 cm $\times$ 25 cm for open and wedged 6 and 10MV X-ray beams. The relative outputs for wedged fields to 10 cm $\times$ 10 cm have been obtained. The results show the Increase of the wedge factor caused by the change in fluence of high energy Photon beam with field size, up to 8.0% for KD77-6MV X-ray beam. This increase could be explained as a linear function of the irradiated wedge volume except small field size up to about 10 cm. In the cases of the narrow rectangular beam parallel to the wedge direction, the wedge factor decreases slightly with increasing field size up to about 10-15 cm due to a relatively reduced photon fluence from the change of the wedge thickness. We could explain the causes of a wedge factor variation with field size as the fluences of primary photon passed throughout the wedge, contributing to the dose at the central beam axis and that the fluences were affected by the gradient of the wedge with the change of field size. For clinical use, the formula developed to describe the wedge factor variation with field size has been corrected.

  • PDF

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Anxiety, Impulsiveness, and Drinking Problems in Employed Women (직장 여성의 불안, 충동성과 음주문제)

  • Lee, Hyun Jae;Han, Doug Hyun;Lee, Young Sik;Kee, Baik Seok;Kwon, Hye Jin;Park, Doo Byung
    • Anxiety and mood
    • /
    • v.7 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • Objectives : This study examined drinking habits, anxiety, and impulsiveness in employed women. Methods : We sampled 925 residents aged over 20 years in Gwanak-gu of Seoul. In the process, we divided subjects into employed women and unemployed women groups and then used the Korean Version of Alcohol Use Disorder Identification Test (AUDIT-K), State-Trait Anxiety Inventory (STAI), and Barratt Impulsiveness Scale (BIS) to identify patterns in subjects' alcohol drinking, anxiety and impulsiveness. Results : Among the 925 respondents, 95.7% drank alcohol, and after the analysis, female problematic drinking ($12{\leq}AUDIT-K{\leq}25$) and alcohol dependence ($AUDIT-K{\geq}26$) was apparent in 61 (9.5%) and 2 respondents (0.3%), respectively. Female respondents who had jobs tended to drink more and exhibit higher ratios of problematic drinking, with a higher exposure to alcohol than those that were unemployed. The psychological attributes related to female respondents' alcohol problems related to state of anxiety and impulsiveness. Employed women respondents also showed a higher state of anxiety and impulsiveness than unemployed women. Conclusion : Controlling the frequency of exposure to alcohol, anxiety, and impulsiveness in employed women should be considered to be crucial controlling factors related to the hazards of excessive drinking.

Fault Injection Based Indirect Interaction Testing Approach for Embedded System (임베디드 시스템의 결함 주입 기반 간접 상호작용 테스팅 기법)

  • Hossain, Muhammad Iqbal;Lee, Woo Jin
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.9
    • /
    • pp.419-428
    • /
    • 2017
  • In an embedded system, modules exchange data by interacting among themselves. Exchanging erroneous resource data among modules may lead to execution errors. The interacting resources produce dependencies between the two modules where any change of the resources by one module affects the functionality of another module. Several investigations of the embedded systems show that interaction faults between the modules are one of the major cause of critical software failure. Therefore, interaction testing is an essential phase for reducing the interaction faults and minimizing the risk. The direct and indirect interactions between the modules generate interaction faults. The direct interaction is the explicit call relation between the modules, and the indirect interaction is the remaining relation that is made underneath the interface that possesses data dependence relationship with resources. In this paper, we investigate the errors that are based on the indirect interaction between modules and introduce a new test criterion for identifying the errors that are undetectable by existing approaches at the integration level. We propose a novel approach for generating the interaction model using the indirect interaction pattern and design test criteria that are based on different interaction errors to generate test cases. Finally, we use the fault injection technique to evaluate the feasibility and effectiveness of our approach.

Frequency-to-time Transformation by a Diffusion Expansion Method (분산 전개법에 의한 주파수-시간 영역 변환)

  • Cho, In-Ky;Kim, Rae-Yeong;Ko, Kwang-Beom;You, Young-June
    • Geophysics and Geophysical Exploration
    • /
    • v.17 no.3
    • /
    • pp.129-136
    • /
    • 2014
  • Electromagnetic (EM) methods are generally divided into frequency-domain EM (FDEM) and time-domain EM (TDEM) methods, depending on the source waveform. The FDEM and TDEM fields are mathematically related by the Fourier transformation, and the TDEM field can thus be obtained as the Fourier transformation of FDEM data. For modeling in time-domain, we can use fast frequency-domain modeling codes and then convert the results to the time domain with a suitable numerical method. Thus, frequency-to-time transformations are of interest to EM methods, which is generally attained through fast Fourier transform. However, faster frequency-to-time transformation is required for the 3D inversion of TDEM data or for the processing of vast air-borne TDEM data. The diffusion expansion method (DEM) is one of smart frequency-to-time transformation methods. In DEM, the EM field is expanded into a sequence of diffusion functions with a known frequency dependence, but with unknown diffusion-times that must be chosen based on the data to be transformed. Especially, accuracy of DEM is sensitive to the diffusion-time. In this study, we developed a method to determine the optimum range of diffusion-time values, minimizing the RMS error of the frequency-domain data approximated by the diffusion expansion. We confirmed that this method produces accurate results over a wider time range for a homogeneous half-space and two-layered model.

A CLINICAL STUDY ON SKELETAL ANCHORAGE SYSTEM USING MINISCREW (구내고정원을 이용한 교정 치료중 miniscrew 탈락에 관한 연구)

  • Woo, Soon-Seop;Jeong, Soon-Tai;Huh, Young-Sung;Hwang, Kyung-Gyun;Yoo, Im-Hag;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.2
    • /
    • pp.102-107
    • /
    • 2003
  • At orthodontic treatment, we have made every effort to get rigid anchorage which is not stirred when teeth move. As a result, the miniscrew that is rigid anchorage was invented recently, and now it is used widely. Concerning the advantage of miniscrew, it is reduced dependence of extraoral anchorage and it shortens treatment time for rapid tooth movement. In contrast, the defect of miniscrew is falling off it resulted from increasing of the mobility. So the purpose of this research is to be of help to prognose clinical use of miniscrew, which is inserted for intraoral anchorage, by investigating and comparing the failure rate of miniscrew for loading time. This study researches the failure rate of miniscrew for teeth movement at the orthodontic treatment. The failure rate of miniscrew in mid course, after inserting 147 miniscrews in 51 patients, is 13%(20/147). It showed no statistically significant differences as compared man with woman, maxilla with mandible, double-head with uni-head miniscrew, and drilling and non-drilling before inserting the miniscrew. In comparison below twenties with over twenties and the times that we give load to miniscrew, it produced that the failure rate of miniscrew is 9.7% higher in the case of below the twenties than over the twenties. Also, the failure rate of loading immediately is 10.8% higher than loading after 7 days. According to using driver for the insertion of miniscrew, the failure rate of miniscrew is higher in the case of using machined driver than in the case of using hand driver when the level of significance is 95%. According to the research, we can suppose that the failure rate has no concern with using miniscrew on man or woman, maxilla or mandible, the shape of head, and drilling or non-drilling before insertion of miniscrew. Therefore, we can choose eclectic miniscrew as demands. In addition, we must notify the patient, below twenties, to be possibility of high failure rate. And It is strongly recommended to give load after $1{\sim}2$ weeks for healing of the insertion area.

Managerial Ownership and Debt Choice (경영자 소유구조와 부채선택)

  • Choi, Jeongmi
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.177-188
    • /
    • 2013
  • This study examines how managerial ownership structure affects the borrower's choice of private versus public debt using 2,608 firm-year data for 2006-2008. This paper investigates the relationship between managerial ownership structure and debt choice. Managerial ownership is measured using number of stocks and unexercised stock-options and debt is classified public and private debt. The results find that there is a positive association between managerial ownership and the private debt dependence and also find that when firms finance additional funds, higher managerial ownership leads managers to choose private debt not public debt. Since private debt can be classified into bank debt and non bank debt, this paper examines the relationship between managerial ownership and a choice of bank debt. The results indicate that managers with higher ownership are more likely to use bank debt over public debt and non bank debt. By examining the relation between managerial ownership and a debt choice, this paper has following contributions. First, this study shows that managerial ownership affects the choice of the source of financing using three different proxies of managerial ownership. Second, this study classified private debt into bank debt and non-bank debt and provide the evidence of preference toward private debt especially bank debt among other financing sources. Finally, there are extensive studies related to capital structure and managerial ownership, but there is little empirical research on the debt choice and managerial ownership. Thus, this paper adds to literature by exploring the effects of managerial ownership on a debt choice.

Seismic attenuation from VSP data in methane hydrate-bearing sediments (메탄 하이드레이트 부존 퇴적층으로부터 획득한 수직탄성파 (VSP) 자료에서의 탄성파 진폭 감쇠)

  • Matsushima, Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • Recent seismic surveys have shown that the presence of methane hydrate (MH) in sediments has significant influence on seismic attenuation. I have used vertical seismic profile (VSP) data from a Nankai Trough exploratory well, offshore Tokai in central Japan, to estimate compressional attenuation in MH-bearing sediments at seismic frequencies of 30-110 Hz. The use of two different measurement methods (spectral ratio and centroid frequency shift methods) provides an opportunity to validate the attenuation measurements. The sensitivity of attenuation analyses to different depth intervals, borehole irregularities, and different frequency ranges was also examined to validate the stability of attenuation estimation. I found no significant compressional attenuation in MH-bearing sediments at seismic frequencies. Macroscopically, the peaks of highest attenuation in the seismic frequency range correspond to low-saturation gas zones. In contrast, high compressional attenuation zones in the sonic frequency range (10-20 kHz) are associated with the presence of methane hydrates at the same well locations. Thus, this study demonstrated the frequency-dependence of attenuation in MH-bearing sediments; MH-bearing sediments cause attenuation in the sonic frequency range rather than the seismic frequency range As a possible reason why seismic frequencies in the 30-110 Hz range were not affected in MH-bearing sediments, I point out the effect of thin layering of MH-bearing zones.

CO and C3H8 Oxidations over Supported Co3O4, Pt and Co3O4-Pt Catalysts: Effect on Their Preparation Methods and Supports, and Catalyst Deactivation (Co3O4, Pt 및 Co3O4-Pt 담지 촉매상에서 CO/C3H8 산화반응: 담체 및 제조법에 따른 영향과 촉매 비활성화)

  • Kim, Moon-Hyeon;Kim, Dong-Woo;Ham, Sung-Won
    • Journal of Environmental Science International
    • /
    • v.20 no.2
    • /
    • pp.251-260
    • /
    • 2011
  • $TiO_2$- and $SiO_2$-supported $Co_3O_4$, Pt and $Co_3O_4$-Pt catalysts have been studied for CO and $C_3H_8$ oxidations at temperatures less than $250^{\circ}C$ which is a lower limit of light-off temperatures to oxidize them during emission test cycles of gasoline-fueled automotives with TWCs (three-way catalytic converters) consisting mainly of Pt, Pd and Rh. All the catalysts after appropriate activation such as calcination at $350^{\circ}C$ and reduction at $400^{\circ}C$ exhibited significant dependence on both their preparation techniques and supports upon CO oxidation at chosen temperatures. A Pt/$TiO_2$ catalyst prepared by using an ion-exchange method (IE) has much better activity for such CO oxidation because of smaller Pt nanoparticles, compared to a supported Pt obtained via an incipient wetness (IW). Supported $Co_3O_4$-only catalysts are very active for CO oxidation even at $100^{\circ}C$, but the use of $TiO_2$ as a support and the IW technique give the best performances. These effects on supports and preparation methods were indicated for $Co_3O_4$-Pt catalysts. Based on activity profiles of CO oxidation at $100^{\circ}C$ over a physical mixture of supported Pt and $Co_3O_4$ after activation under different conditions, and typical light-off temperatures of CO and unburned hydrocarbons in common TWCs as tested for $C_3H_8$ oxidation at $250^{\circ}C$ with a Pt-exchanged $SiO_2$ catalyst, this study may offer an useful approach to substitute $Co_3O_4$ for a part of platinum group metals, particularly Pt, thereby lowering the usage of the precious metals.

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF