• Title/Summary/Keyword: Use of Facility

Search Result 1,742, Processing Time 0.029 seconds

A Study on Personalized Emotion Recognition in Forest Healing Space - Focus on Subjective Qualitative Analysis and Bio-signal Measurement - (산림 치유 공간에서의 개인 감정 인지 효과에 관한 연구)

  • Lee, Yang-Woo;Seo, Yong-Mo;Lee, Jung-Nyun;Whang, Min-Cheol
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.2
    • /
    • pp.57-65
    • /
    • 2019
  • This study is a scientific approach to psychological factors such as emotional stability among various effects of forest resources. In order to carry out this study, the experiment was conducted on the subjects by setting the forest healing space as various spaces. The subjects who participated in this experiment were the students in their twenties and the average age was 22±1.25 years. The subjects were assessed for emotional words through subjective sequence evaluation in different designated forest healing spot. In addition, the emotional states that they actually perceived were measured by measuring the bio-signals to their perceived emotions. BMP, SDNN, VLF, LF, HF, Amplitude, and PPI were used for the bio-signal reaction experiment applied to this study. The results of this experiment were measured by Friedman test and Wilcoxon test for statistical analysis. n this study, 'good', 'clear', and 'uncomfortable' words were found statistically significant at the spot of forest healing space for subjective emotional vocabulary. In addition, SDNN, HF and Amplitude were statistically significant in the results of quantitative bio-signal measurement at each spot in the forest healing space. Based on the results of this study, we can suggest the application direction and strategic utilization plan of forest healing spot and forest resource utilization field. This is not only a guide for the users who use the facility through the spatial facilities and physical requirements for the emotion based forest-healing, but also can be used as a personalized emotional space design aspect.

Situations of GAP certified ginseng and 4P's strategies (GAP 인증인삼 현황과 4P 전략)

  • Hong, Seung-Jee;Kim, Kwan-Hoo
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.2
    • /
    • pp.369-381
    • /
    • 2011
  • Ginseng in Korea has not only the big production value but also till a good reputation from overseas in the name of 'Korea Ginseng'. Having spread rapidly nationwide from 2000 year, its production keeps on increasing but its consumption becomes lazy and its price is also falling down because of comsumer's concern about mainly overusing pesticide for ginseng. In order to cope with this problem, the government introduced the GAP certification system to ginseng in 2006 to reflect consumer's needs for food safety. This system will be a good opportunity to promote ginseng consumption dramatically. In this aspect it is very important to know how well this system is established and how ginseng farmers build marketing strategies to draw new wind in the market. This study was carried out to look over the GAP certified ginseng system and show its marketing strategies using 4P's(product, place, promotion and price). The main results are as follows. GAP ginseng system currently has some weaknesses such as lack of systematic certification management and after-service, nonrealistic certification fee and poor linkage from production to consumption. In the marketing mix strategies, product strategy suggests that the most desirable appearance be transplanted ginseng filled with branch roots and 4 to 5 year-ginseng, and it is necessary to choose multi-brand strategy divided for present into for self-sufficiency and family brand strategy by use if its brand enlarges to processed products in the future. In the place strategy, 3 stages like 'producer group' - 'GAP certified facility' - 'sales shop' are based as the physical marketing channel according to traceability, and connected with giant retail market and environment friendly stand, and if its sales volume enlarges, it should be considered the GAP ginseng specialized marketplace which is a type of chain store. In the promotion strategy, the promotion of government level is necessary at first and producer alliances require the promotion targeting at the group of women under 40 with differentiation from price, quality, and safety. In the price strategy, the early stage-high price strategy which sets 20~25% higher for self-sufficiency and 30~35% for present is desirable.

Survey and model development of the mechanization for swine farming (양돈농가의 기계화 실태분석 및 모델개발)

  • 이성현;박원규;강창호;오권영
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.91-108
    • /
    • 1998
  • This study was carried out to survey basic information of swine farms on the machine holdings. facility type. management of manure by farm scale and operation, and then to develop the mechanization model. Manual feeding was common for sows and nursing sows. but automation feeding was normally furnished for weaners. growing pigs and castrated male pigs. Water supplies was completely automated for all of the surveyed swine farms. Fully mechanized and automated system would not be feasible and affordable for the small scale farms breeding less than 500 heads. Because the environmental control for the nursing sows and weaner was important, some swine houses were constructed with the windowless type. However, the furnished rates ranged from 22.2% to 44.4% of the surveyed nursing sow and weaner houses at the farm scales. In the future, a computerized ventilation system would be commended for the efficient use of heat energy and to maintain the desirable temperature of swine buildings. Over-investment for large scale farm and over-crowded pigpen of small farm would cause wasting construction expenses and spreading epidermic diseases Hence, the size of swine building should follow the recommended scale. The fermentation drier was recommended for the manure management. Urine could be recycled or discharged after treating by the activated sludge process.

  • PDF

Research on Classification of Monitoring Items for the Integrated Management of the Underground Facilities (지하시설물 통합관리를 위한 모니터링 항목 분류에 관한 연구)

  • Kim, Jung-Hoon;Min, Kyung-Ju;Lee, Mi-Sook;Lim, Si-Yeong
    • Spatial Information Research
    • /
    • v.18 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • It is important to manage the underground facilities efficiently because they are directly related to the convenience and safety of citizens. But the fact that the different agencies take on a role of managing the underground facilities respectively makes it impossible. So Korean government has exerted great efforts to solve this problem through several projects. Korean government expects that the ubiquitous technologies such as sensor and wireless communication in the domain of the underground facilities management will be useful. It is main duty of u-City Management Center to monitor several situations about the underground facilities using ubiquitous technologies. But there is no consensus about what concrete situations it has to monitor even though u-cities under construction. Because local governments or related companies are in charge of carrying out these roles yet, there is no legal basis on which to do these tasks by the center. And it is needed to develop new technologies for u-services efficiently. Because technologies for u-service are vast, various and converged, so it necessary to develop them according to priority or in cooperation with other developers. In this paper, we classify the monitoring items for each facility which were investigated by a recent research. It is expected to make use of defining the role of the center and developing technologies with u-service.

A Simulation Study for Evaluation of Alternative Plans and Making the Upper-limit for Improvement in Productivity of Flow-shop with Considering a Work-wait Time (흐름생산 공정에서의 작업 대기시간을 고려한 공정 개선 상한선 도출 : H사의 공정 개선 계획안 시뮬레이션 사례를 중심으로)

  • Song, Young-Joo;Woo, Jong-Hun;Lee, Don-Kun;Shin, Jong-Gye
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.2
    • /
    • pp.63-74
    • /
    • 2008
  • The design of best efficient production process is common requirements of the production strategy department and the process planning department to maximize the revenue and accomplish target production volumes in the production periods. And they use several general methods for that-line-balancing, removing of the bottle-neck process, facility ramp-up, increasing of the worker's utilization, etc. But, those methods have depended on analytic, static and arithmetic calculations, yet. So, irregular work-waiting time causing the delay time isn't include in extracting production capacity, especially in the line production process. The work-waiting time is changed irregularly along the variation of each machine and very important for calculate real product lead-time and forecasting target production volumes. At this thesis, i'm going to mention the importance of the delay time of conveyor system which can be extracted by discrete-event simulation. And suggest it as a new main variable that must be considered at designing new production system. Then experimented and tested that's effects in the H-company case, conveyor based line production process.

  • PDF

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.

Experimental study on applicability of compressed air foam fire water using seawater in train fire at subsea tunnel rescue station (해저터널 구난역 열차화재시 압축공기포 소화용수의 해수 적용성에 관한 실험 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.705-715
    • /
    • 2017
  • In this study, applicability of compressed air form (CAF) fire water was verified in a bid to use the undersea effluent as fire water. Foam collector was fabricated in accordance with KS B ISO 7203-1 (Specification for low expansion foam concentrates for top application to water-immiscible liquids) and the test was conducted using fresh water as fire water for 19 times and using seawater as fire water 15 times that totaled 34 times. Foam reduction time was 237.73 seconds on average with fresh water and 215.60 seconds with seawater, which proved the applicability of CAF fire water using seawater. Besides, window breaker was fabricated to directly extinguish the fire in train and a full-scale fire test was conducted three times. At the final 3rd test, window glass was broken in 2 seconds to make the hole for fire extinguishing and suppressed the fire in 3 seconds using CAF fire extinguisher.

A Study on the Development of Field Management System for Underground utility using Self-levelling marker and DGPS. (자동수평마커와 DGPS를 이용한 지하시설물의 현장관리시스템 개발에 관한 연구)

  • Kim, In-Seup
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.6
    • /
    • pp.733-739
    • /
    • 2009
  • Recently it is being increased rapidly to install magnetic marker and RFID tag on the underground utility lines before backfilling to ensure effective it's management. However, due to changes an attitude and damages of sensors. By pressure and vibration during soil compacting, detecting rate is significantly reduced as well as it allows to use only one line of various pipes since it has an unique frequency. Also it is required too long time to reach to target point with an non-accurate navigational GPS receiver and hard to update existing data base with a manual input of new data in the field. To improve these problems, the researcher developed the field management system that apply with ball typed self-levelling marker which is free from the changes of attitude for sensors during compaction as well as has various radio frequency applicable to many kind of pipes and ensure fast positioning to target point using an incorporated system with PDA based DGPS receiver which allows loading a field GIS software and RFID detector. Further, it provides with viewing all of RFID data on the DGPS receiver screen directly and also input new data to existing data base in the field automatically.

A Study on the Current Status Analysis of Reasonable Accommodations at Exhibition Facilities (전시시설의 정당한 편의 제공 실태에 관한 연구)

  • Lee, Kyoo Il;Kim, In Soon;Lee, Ki Jung;Lee, Tae Eun
    • 재활복지
    • /
    • v.17 no.4
    • /
    • pp.311-338
    • /
    • 2013
  • The Act of Disability Discrimination and Rights Restriction was enacted in 2008 states that all services including cultural and artistic activities should be fair and easily accessible for disabled. The aim of this study was to determine how to improve the facilities and services for the disabled in exhibition facilities and provide complementary guidelines for amenities designed for people with disabled. The conclusions identified through this study are as follows: 1) It should be installed pedestrian safe passage so that visitors could access from the entrance of the ground to inside of the exhibition facility. 2) The floor of the exhibition hall should be installed not slip, and dangerous obstacles placed in the corridor should be removed. 3) It Should be considered that visually impaired and wheelchair users are use different facilities at toilet and elevator. 4) To guide the visually impaired and hearing impaired it should be prepared palpable map, braille signage, miniature and brochures. 5) Visually impaired and hearing impaired can experience the exhibits by using a variety of senses, therefore it may need to provide assistive devices and human services.

Clinical Microscopy: Performance, Maintenance and Laser Safety (임상에서의 현미경: 작동, 유지보수 및 레이저 안전)

  • Lee, Tae Bok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • A microscope is the fundamental research and diagnostic apparatus for clinical investigation of signaling transduction, morphological changes and physiological tracking of cells and intact tissues from patients in the biomedical laboratory science. Proper use, care and maintenance of microscope with comprehensive understanding in mechanism are fully requested for reliable image data and accurate interpretation for diagnosis in the clinical laboratory. The standard operating procedure (SOP) for light microscopes includes performance procedure, brief information of all mechanical parts of microscopes with systematic troubleshooting mechanism depending on the laboratory capacity. Maintenance program encompasses cleaning objective, ocular lenses and inner optics; replacement and calibration of light source; XY sample stage management; point spread function (PSF) measurement for confocal laser scanning microscope (CLSM); quality control (QC) program in fluorescent microscopy; and systematic troubleshooting. Laser safety is one of the concern for medical technologists engaged in CLSM laboratory. Laser safety guideline based on the laser classification and risk level, and advisory lab wear for CLSM users are also expatiated in this overview. Since acquired image data presents a wide range of information at the moment of acquisition, well-maintained microscopes with proper microscopic maintenance program are impulsive for its interpretation and diagnosis in the clinical laboratory.