• 제목/요약/키워드: Upper Plate

검색결과 588건 처리시간 0.031초

경량전철 2주형 판형교 복부판의 탄성좌굴 특성 (Elastic Buckling Characteristics of Plate Girder Web Panel)

  • 황민오;성택룡;윤태양;이안호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.344-351
    • /
    • 2000
  • In the design of plate girder web panels, it is required to evaluate accurately the elastic buckling strength under pure shear, pure bending and combined bending and shear. Currently, elastic buckling coefficients of web panels stiffened by transverse intermediate stiffeners are determined by assuming conservatively that web panels are simply supported at the juncture between the flange and web. However, depending upon the geometry and the properties of the plate girder bridge, upper juncture between the flange and web can be assumed as fixed because concrete deck prevents the rotational displacement of upper flange. In the present study, a series of numerical analyses based on finite element modeling is carried out to investigate the effects of the concrete deck, and the resulting data are quantified in simple equations.

  • PDF

분리형 스페리칼 교량받침의 특징 및 교체실험 (Characteristics and Replacement of Separated Spherical Bridge Bearings)

  • 박성우;유승규;최은수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1729-1734
    • /
    • 2008
  • This study developed a new separated shperical bridge bearing that can be used for replacement of existing bridge bearings without crushing bearing-concrete. The separated spherical bearing have the upper and lower sole plate connected by bolts to the upper plate under bridge-girders and the lower plate on bearing-concrete. The targets of the separated spherical bearing are the maximum 3 mm of up-lifting height during replacement and the maximum required time of 30 minutes. Four separated spherical bearings are manufactured and replaced the existing bearings of a railway bridge in service and the replacing tests was performed. The number of the tests is two and the target of maximum 3 mm and 30 minutes was satisfied.

  • PDF

리프리스트레스트 프리플렉스 합성형의 최적설계에 관한 연구 (A Study on the Optimal Design of Represtressed Preflex Beams)

  • 조병완;김정호;조태준;김도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.712-717
    • /
    • 1998
  • Represtressed preflex beams do not allow tensile stress under service load by introducing additional prestressing at the lower concrete of beams. In this study, optimal design of represetressed preflex beams are numerically investigated. Design variables are dimension of plate girder. Object function is the total weight of plate girder. Constraints of the stress of plate girder and upper and lower concrete flange and lower and upper bounds on the design variables are imposed. Structural analysis is performed by D.A.R.P.(Design and Analysis of Represtressed Preflex beams). For numerical optimization, ADS(Garret N. Vanderplaats) program is used. From result of application examples, optimum designs of different cases are successfully obtained. The design program developed in this study seems efficient and robust for the optimization of represtressed preflex beams.

  • PDF

304 스테인리스강의 Plug 용접성에 관한 연구 (A Study on the Plug Weldability of 304 Stainless Steel)

  • 황종근;장경복;강성수
    • Journal of Welding and Joining
    • /
    • 제16권1호
    • /
    • pp.106-113
    • /
    • 1998
  • In this study, the plug weldability of STS 304 was investigated. The parameters which influence plug weldability were pushing pressure of the plates, position of welding wire and composition of shielding gases. Among these factors, the composition of shielding gases and hole diameter of the upper plate were found to be the major factors influencing weld quality. To evaluate weldability, tensile shear strength of the plug welded specimen was measured and compared with tensile strength of butt welded specimen. Hardness was measured for both plug weld and butt weld. The microstructure of the weld metal and HAZ were also characterized.

  • PDF

평판 핀 열교환기의 성능 향상을 위한 변형된 평판 핀에 대한 해석 (Analysis of a Modified Plate Fin for Enhanced Performance of a Plate Fin Heat Exchanger)

  • 김윤하;강형석
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.84-91
    • /
    • 2001
  • Comparison between performance of a plate fin and that of a modified plate fin is investigated as a function of the position, the non-dimensional width and height of wings as well as the non-dimensional fin length using a two-dimensional separation of variables method. The ratio of the incremental rate of heat loss to that of the area of a modified plate fin is also presented as a function of the height of wings. The modified plate fin is made by attaching the wings to upper and lower sides of a plate fin. One of the results shows that performance of a modified plate fin is more improved as the wings approach left (higher) thermal reservoir.

  • PDF

반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향 (Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process)

  • 박준수;권현구;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

Number Plate Detection System by Using the Night Images

  • Yoshimori, S.;Mitsukura, Y.;Fukumi, M.;Akamatsu, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1249-1253
    • /
    • 2003
  • License plate recognition is very important in an automobile society. This is because, since plate detection accuracy has large influence on subsequent number recognition, it is very important. However, it is very difficult to do it, because a background and a body color of cars are similar to that of the license plate. In this paper, we propose a new thresholds determination method in the various background by using the real-coded genetic algorithm (RGA). By using RGA, the most likely plate colors are decided under various lighting conditions. First, the average brightness Y values of images are calculated. Next, relationship between the Y value and the most likely plate color thresholds (upper and lower bounds)are obtained by RGA. The relationship between thresholds decided from RGA and brightness average is aproximate by using the recursive least squares (RLS) algorithm. In the case of plate detection, thresholds are decided from these functions.

  • PDF

통합히터 성능평가장치를 통한 생산 공정 개선 (Improvement of Production Process based on Performance Evaluation System of Unified Heater)

  • 한우현;윤달환
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.114-118
    • /
    • 2014
  • 본 연구에서는 디젤 차량용 통합형 연료히터와 성능검사 시스템구현을 통해 생산공정을 개선한다. 센서와 히터가 분리된 연료히터를 히터내에 센서를 안착시켜 통합함으로써 일체형 통합히터를 개발하고, 성능평가 시스템 개발을 통하여 시험한다. 이때 성능평가 시스템은 통합히터를 구성하는 body, upper plate, stopper, lower plate, PTC, screw, 바이메탈 및 외부 터비날의 특성을 분석하고, 통합히터의 생산성을 결정한다. 저온 유동성시험장치에서는 극저온에서 고온사이 동작검사, 시험저항 설정에 따른 저항동작지연 및 전류동작지연, 온도변화에 따른 바이메탈 지연 검사, 블록히터의 전류 및 저항 검사, 히팅 운전검사 등을 수행한다. 따라서 효율적인 생산공정 과정을 통해 연료히터의 성능을 개선하는 생산공정 개선 알고리즘을 제시한다.

대형 컨테이너선 상갑판 해치코너부 보강판의 설계에 관한 연구 (Study on the Design of Upper Deck Hatch Corner Insert Plates of Large Container Carriers)

  • 박성구;이주성
    • 대한조선학회논문집
    • /
    • 제43권3호
    • /
    • pp.331-339
    • /
    • 2006
  • The objective of this paper is to calculate the fatigue strength for upper deck hatch corner insert plate of large container carriers without wave load analysis and global finite element analysis at the initial design stage. Wave load analysis and global F.E. analysis for three container carriers have been performed by GL(Germanischer Lloyd) procedure to propose the equation for hatch corner stress range which is the important factor in fatigue strength calculation. Considering the restraining effect of bulkhead, three types of equation, that is, single tight bulkhead, double tight bulkhead and support bulkhead have been proposed. Using the proposed equations, a simplified fatigue analysis based on GL rules has been performed for two container carriers of which fatigue strength analysis was carried out by GL. From the comparison between fatigue strength result of using the proposed equations and that of GL, it has been found that proposed stress range equations are useful for scantling of upper deck hatch corner insert plates for over 8,000 TEU class container carriers.

압력 조절 장치를 갖는 풍동 지면판에 관한 수치해석적 연구 (NUMERICAL STUDY ON WIND TUNNEL GROUND PLATE WITH A PRESSURE CONTROL DEVICE)

  • 이민재;김철완
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.53-59
    • /
    • 2010
  • Preliminary design of a ground plate, a device installed close to the aircraft model for wind tunnel test to simulate the ground effect, was performed by a numerical simulation. A two-dimensional numerical study was performed initially to decide the optimal leading edge and flap configurations. Then, three-dimensional studies were conducted to decide the optimal flap deflection angle for pressure distribution reduction since the plate and the plate supporting system generate static pressure difference between the upper and lower flow regions. Three-dimensional simulation additionally studied the effect of the clearance between the plate and the wind tunnel side wall. For the efficiency of computation, half model was simulated and a symmetric boundary condition was applied on the center plane. Based on the preliminary design, a ground plate was designed, manufactured and tested at the Korea Aerospace Research Institute(KARI) wind tunnel. The measured pressure differences versus flap deflection angle agreed well with the predicted results.