• Title/Summary/Keyword: University Entrance Examination

Search Result 153, Processing Time 0.026 seconds

A Review on the Relationship of Milk Consumption, Dietary Nutrient Intakes and Physical Growth of Adolescents (청소년의 우유 섭취,영양 섭취 및 신체 발달간의 관계에 대한 고찰)

  • Kim, Sun-Hyo
    • Journal of Dairy Science and Biotechnology
    • /
    • v.28 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • Adolescents grow rapidly and have lots of schoolwork for entrance examination, so good nutrition is very important to them. However, adolescents tend to have a poor dietary behavior including frequent consumption of empty calorie foods and skipping breakfast. In particular, frequency of drinking milk has been low among Korean adolescents, thus their dietary calcium intakes has been low. Undesirable dietary behavior of adolescents is a risk factor for poor nutrition, obesity and chronic disease of them. Milk is a good source for calcium, high quality of protein, vitamin and bioactive compounds including anti-obesity component, thus it has been reported that milk helps improvement of dietary nutrient adequacy and physical growth, increment of bone mineral density, and prevention of obesity and chronic diseases. Therefore, milk consumption of adolescents should be encouraged in order to help their nutritional status, physical growth and health.

  • PDF

The Bad Effect of Mixed Evaluation and the Role of Mathematical Education (혼용평가 폐해와 수학교육의 역할)

  • Moon, Kwon-Bae
    • The Mathematical Education
    • /
    • v.47 no.3
    • /
    • pp.387-398
    • /
    • 2008
  • In this paper, the mathematical knowledges in higher education which are capable of improving the ability of the problem, scientific techniques and creativity are pinpointed as crucial necessary conditions for the development of the Engineering and Natural Science Sections. It is stressed most of all that the mixed evaluation of mathematics in college entrance examination is the main culprit to the crisis of these sections and thus the strengthening of the mathematics education is vital to the section. Also, another role of mathematical education for these sections is introduced.

  • PDF

A Case Study on the Teaching Method of the "Noise" Unit (소음 단원의 교수-학습 모형 개발 및 적용에 관한 현장 연구)

  • 송호열
    • Hwankyungkyoyuk
    • /
    • v.15 no.2
    • /
    • pp.14-29
    • /
    • 2002
  • The environment of the world becomes deteriorated rapidly as the result of the development of technology, the increase of the standard of living, and the growth of population. These circumstances called for environmental education in Korea, creating an environment course in the middle and high school in 1995. Despite the increasing importance of environmental education, however, the situation has not developed in its favor because of the current system of the university entrance examination. The school has failed to develop the curriculum of environmental education in the secondary education. This paper solves this problem internally in terms of the improvement of the contents, organization, teaching method (role-playing game), and teaching materials of environmental education, with a case study of the “noise” unit in 10th grade. This case study expects to change the attitude toward noise, increase the interest and knowledge in environment, and lead to responsible environmental behavior.

  • PDF

Results of "Suneung" and Errors on Writing

  • Lee, Eun-Pyo
    • English Language & Literature Teaching
    • /
    • v.8 no.2
    • /
    • pp.55-69
    • /
    • 2003
  • The study was done to find out if there's any correlation between the results of the state-run college entrance examination called "suneung," or college scholastic ability test (CSAT) and the frequency of errors of the medical and nursing students. These two groups of students were subjects for the research. The study was based on the writing of fresh year students who were required to take four-credit-hour English course. These students' writing, particularly their self introduction, was analyzed to see if medical students (the high-scored) made fewer errors on the writing and nursing students (the medium-scored) made more critical errors or vice versa, and furthermore, if the results of the scores had any correlation on the critical errors in writing. The concern of the study was also to explain the attributable factors of the outcome if the high-scored of CSAT actually made fewer errors as well as the types of critical errors made and ways to minimize them.

  • PDF

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Investigation of organ dose difference of age phantoms for medical X-ray examinations (X선 촬영 시 연령별 장기선량 차이 연구)

  • Park, Sang-Hyun;Lee, Choon-Sik;Kim, Woo-Ran;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Methodology for calculating the organ equivalent doses and the effective doses of pediatric and adult patients undergoing medical X-ray examinations were established. The MIRD-type mathematical phantoms of 4 age groups were constructed with addition of the esophagus to the same phantoms. Two typical examination procedures, chest PA and abdomen AP, were simulated for the pediatric patients as well as the adult as illustrative examples. The results confirmed that patients pick up approximate 0.03 mSv of effective dose from a single chest PA examination, and 0.4 to 1.7 mSv from an abdomen AP examination depending on the ages. For dose calculations where irradiation is made with a limited field, the details of the position, size and shape of the organs and the organ depth from the entrance surface considerably affect the resulting doses. Therefore, it is important to optimize radiation protection by control of X-ray properties and beam examination field. The calculation result, provided in this study, can be used to implement optimization for medical radiation protection.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

A Study on the Laboratory Function and Spatial Organization for Laboratory Medicine - Focused on the Tertiary Level General Hospitals having more than 1000 Beds (진단검사의학과의 검사기능과 공간구성에 관한 연구 - 1000병상급 종합병원을 중심으로)

  • Choi, Changdae;Kim, Youngaee
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.4
    • /
    • pp.37-53
    • /
    • 2017
  • Purpose: As the structure of the disease has been changed and the infectious disease has been increased, the demand for diagnostic examination has been increasing. So, the department of laboratory medicine in hospital has playing the important role accounting for about nineteen percent of total medical expenses in korea. This study is to investigate the laboratory function and spatial composition of the department and figure out the space area and space organization. Methods: Explore the literature review to identify the laboratory function. Limit to five cases of tertiary level general hospital having about a thousand bed and analyze the space layout and floor area to confirm the spatial composition. Classify the exam function and check the spatial composition and spatial organization. Results: This study allows 5 conclusions to be summarized. Laboratory medicine divided into nine part in regulation, but in space allocated into core lab, emergency lab and six part lab. Total laboratory area is $2,036m^2$ in average, and is composited with 60% for lab, 17% for office and 20% for public. Lab area per a bed presents $1.88m^2$. Microbiolgy and molecular lab area are getting large. Laboratory space organized into the four zone, like an entrance zone, core zone, rear zone and peripheral zone. Emergency and transfusion lab are allocated in entrance zone, hematology chemistry and immunology in core lab, microbiology and molecular lab in rear, support offices in peripheral zone. The most important point was to check the spatial composition of the Laboratory Medicine according to the inspection function. Implications: This study can be used as a useful data in planning and designing a Laboratory Medicine Department.

Study on the Direction of College Admission through the Analysis of the 2015 Revised Curriculum : Focused on In-depth Interview with Experts (2015 개정 교육과정 운영 실태 분석을 통한 대학 입시 방향 연구: 전문가 심층 인터뷰를 중심으로)

  • Baek, Min-kyung;Baek, Kwang-ho;Lee, Je-Young
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.11
    • /
    • pp.422-434
    • /
    • 2020
  • This study aims to analyze the types of college admission that should be strengthened or reflected in universities and to suggest the direction of entrance examination by identifying the actual implementation of the literature-science integrated 2015 revised national curriculum. In order to do so, in-depth interviews on the current state were executed to five curriculum experts. As a result of the interview, it was found that the introduction and adoption of clear admission types look into the inner side of high school life are necessary. Also, it is required to establish specific criteria for student selection expand in-depth interviews related to learning activities in high school, strengthen evaluation competence of admission staffs and recruit more evaluation personnel. In addition, in order to revitalize the 2015 revised curriculum, it is necessary to evaluate how many subjects, especially in career-related subjects, students have taken in order to expand the school record-focused system. For this, it is required to extract evaluation elements and criteria of universities that can grasp continuous and active role performance, and to design a typical design that can objectively judge them. This study can contribute to the settlement of the selection process that can revitalize public education. And it is expected that the selection of the talents desired by the university will be used as a possible basic data.

Echocardiographic Diagnosis of Subaortic Stenosis with Severe Deformation of Mitral Valve Apparatus in a Dog

  • Chung, Doo-ri;Yoon, Young-min;Hwang, Tae-sung;Choi, Moon-yeong;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.54-57
    • /
    • 2017
  • A 1-year-old castrated male Schnauzer dog was presented with heart murmur. Auscultation revealed systolic murmur located at the left heart base (grade 5/6). There were no remarkable findings on thoracic radiographs. Two-dimensional echocardiography revealed subaortic tunnel-like obstruction at the entrance to the left ventricular outflow tract. Anterior mitral valve leaflet appeared to be tethered to septum with minimal motion. Chordae tendineae was abnormally thickened. Color Doppler analysis revealed turbulent flow starting below the aortic valve. Mitral regurgitation was presented during systole. Spectral Doppler recordings revealed high velocity flow through the aorta and mitral regurgitation. Based on echocardiographic examination, the dog was diagnosed with subaortic stenosis concurrent with mitral dysplasia. The patient was medicated with ${\beta}-blocker$ and diuretics. It has been doing well without apparent clinical signs at 2 year after the diagnosis.